Farklı mukoza kalınlıklarının iki tip implant destekli overdenture dizaynı üzerindeki stres dağılımına etkisi
Effect of different mucosa thickness on stress distrubition of two types implant-supported overdenture designs
- Tez No: 331641
- Danışmanlar: PROF. DR. FİLİZ AYKENT
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Dental stres analizi, Fotoelastisite, Mukozalar, Dental implantation, Dental implants, Dental stress analysis, Photoelasticity, Mucous membrane
- Yıl: 2013
- Dil: Türkçe
- Üniversite: Selçuk Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Farklı mukoza kalınlıklarının, implant destekli mandibular overdenture tasarımlarında stres dağılımına etkisi yeterince değerlendirilmemiştir. Bu çalışmanın amacı fotoelastik stres analiz yöntemi kullanılarak yükleme altında farklı mukoza kalınlığının, iki implant destekli mandibular overdenture tasarımları üzerindeki stres dağılımına etkisini değerlendirmektir. Kaninler bölgesine iki adet bağımsız implant (4,0x11 mm) yerleştirilmiş altı adet alt çene dişsiz fotoelastik modeller üretildi. Çalışılan ataçman sistemler, locator ve ball stud ataçman sistemlerdi. Ball ve locator grupların her ikisi de, farklı mukoza kalınlıkları (1mm-1mm, 1mm-2mm, 1mm-4mm ) sağlayan farklı rezidüel kret yüksekliğine sahip üç farklı modelden oluşmaktadır. Birinci molarların santral fossasına tek taraflı (her birinde sağa ve sola olmak üzere) ve çift taraflı olarak 135 N statik vertikal kuvvet uygulandı. Modeller, yükleme altında implantların etrafında ve implantlar arası bölgede izokromatik fringeleri gözlemek için dairesel polariskop alanına yerleştirildi. Fotoelastik stres fringeleri monitörize edildi ve fotoğrafik olarak kaydedildi. Tek taraflı ve çift taraflı yükleme altında ball ataçman grupları, locator gruplardan daha yüksek stres değerleri gösterdi. Her iki ataçman sistemi de en düşük stres değerlerini 1mm-1mm mukoza kalınlıklı modellerde üretti. Tek taraflı yüklemelerde her iki ataçman sisteminde 1mm-2mm modeller diğer modellerden daha yüksek stres değerleri gösterdi. Tek taraflı yükleme altında bütün gruplar için en yüksek stres değerleri yüklenen taraftaki implantta gözlendi. Çift taraflı yükleme esnasında her iki ataçman sisteminde de aynı modellerde implantlar arasında birbirine yakın stres değerleri gözlendi. Tüm test modellerinde her iki ataçman sisteminde gözlenen en yüksek stres değerleri orta seviyedeydi. Bu in vitro çalışma locator ataçmanın kullanımının implant destekli overdenturelar için stresleri optimize etmek ve daha dengeli stres dağılımı sağlamak açısından avantajlı olduğunu önermektedir. Mukoza kalınlığı implantlar üzerindeki stres dağılımını etkilemektedir. Yapay dişlerin oluşturduğu implant-destekli overdenture protezlerde bilateral balanslı okluzyon avantajlı okluzyon dizaynıdır ki bu durumda dişsiz kret korunur ve daha homojen stres dağılımı sağlanır.
Özet (Çeviri)
The effect of different mucosa characteristics on stress distribution of implant-retained mandibular overdenture designs has not been sufficiently evaluated. The aim of this study was to evaluate the effect of different mucosa thickness on the stress distrubition on two implant-retained mandibular overdenture designs under loading using photoelastic stress analysis method. Six photoelastic models of an edentulous mandibular were fabricated with solitary two implants (4,0x11 mm) which were placed in the canine regions. The attachment systems studied were ball and locator stud attachments. Both ball and locator groups were include three different models which had different residuel ridge height so that provided different mucosa thickness (1mm-1mm, 1mm-2mm, 1mm-4mm). Static vertical force of 135 N was applied unilaterally (each in turn right and left side) and bilaterally to the central fossa of the first molars. Models were positioned in the field of circular polariscope to observe the distribution of isochromatic fringes around the implants and interimplant areas under loading. The photoelastic stress fringes were monitored and recorded photographically. Ball attachment groups were showed higher stress values than locator groups under both unilaterally and bilaterally loading. Both of attachment system produced the lowest stress values in stimulated 1mm-1mm mucosa thickness models. 1mm-2mm models were higher stress values than other models for both attachment system under unilateral loading. The highest stres values were observed which was loaded-side implant for all groups under unilaterally loading. Stress values were observed to close each others for implants in same models for both attachment systems during bilaterally loading. The highest stress value observed with both attachment systems were moderate in all test models. This in vitro study suggested that the use of locator attachment could be advantageous for implant-retained overdenture with regard to optimizing stress and provide more uniform stress distribution. The thickness of mucosa influence to stress values on implants. Bilateral balanced occlusion is a favored occlusal design in setting of artificial teeth in implant-supported overdenture dentures, which preserves edentulous ridge and provide more uniform stress distribution.
Benzer Tezler
- Radyasyon rektiti modelinde ruscogeninin profilaktik ve teröpatik etkisinin değerlendirilmesi (Deneysel çalışma)
Başlık çevirisi yok
ONUR OLGAÇ KARAGÜLLE
Tıpta Uzmanlık
Türkçe
2017
Genel CerrahiSağlık Bilimleri ÜniversitesiGenel Cerrahi Ana Bilim Dalı
UZMAN ERKAN YAVUZ
- Farklı yöntemlerle elde edilen de-epitelize bağ dokusu greftlerinin histolojik ve klinik olarak değerlendirilmesi
Farkli yöntemlerle elde edilen de-epitelize bağ dokusu greftlerinin histolojik ve klinik olarak değerlendirilmesi
AYÇA MUHTEREM
Diş Hekimliği Uzmanlık
Türkçe
2026
Diş HekimliğiDokuz Eylül ÜniversitesiPeriodontoloji Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ELİF İNÖNÜ
- Esansiyel yağlardaki allerjen maddelerin ve pestisit kalıntılarının giderilmesi
Removal of allergen compounds and pesticide residues in essential oils
AYKUT TÜRKMENOĞLU
Doktora
Türkçe
2023
Kimya Mühendisliğiİstanbul Üniversitesi-CerrahpaşaKimya Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ İBRAHİM METİN HASDEMİR
DOÇ. DR. TÜLAY YILDIZ
- Serbest diş eti grefti operasyonu sonrası greft ve alıcı bölge renginin polarize dijital fotoğraf ile analiz edilmesi
Color analysis of graft and recipient site after free gingival graft surgery using polarized digital photograph
ŞEYMA KÖLE
Diş Hekimliği Uzmanlık
Türkçe
2025
Diş HekimliğiBezm-İ Alem Vakıf ÜniversitesiPeriodontoloji Ana Bilim Dalı
DOÇ. DR. ŞADİYE GÜNPINAR
- Laparoskopik sleeve gastrektomi yapılan hastalarda mide duvar kalınlığının ölçülmesi ve uygun stapler kullanımı ilişkisi
The relationship between gastric wall thickness measurement and use of suitable staples in patients undergoi̇ng laparoscopic sleeve gastrectomy
HÜSEYİN TAHSİN GÜLSEVEN
Tıpta Uzmanlık
Türkçe
2019
Genel CerrahiSağlık Bilimleri ÜniversitesiGenel Cerrahi Ana Bilim Dalı
UZMAN OP.DR. HACI HASAN ABUOĞLU