Yoğunluk ayarlı radyoterapide çok yapraklı kolimatör ve hasta dozimetrisi kalite kontrolü

Quality assurance of multileaf collimator and patient dosimeter in intensity modulated radiation therapy

  1. Tez No: 291811
  2. Yazar: GÜLNAR TÜLEK
  3. Danışmanlar: DOÇ. DR. BAHAR DİRİCAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Radyasyon, Radyoterapi, Radyoterapi-bilgisayar yardımlı, Radiation, Radiotherapy, Radiotherapy-computer assisted
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada Gülhane Askeri Tıp Akademisi Radyasyon Onkolojisi Anabilim Dalı'nda bulunan Elekta marka Synergy model Lineer hızlandırıcıda 6 MV x-ışını kullanarak, Step-and-Shoot tekniği ile yoğunluk ayarlı radyoterapide lineer hızlandırıcı kalite kontrolü ve hasta dozimetrisi kalite kontrolü gerçekleştirildi. Öncelikle çok yapraklı kolimatör (ÇYK) pozisyon doğruluğu testi, ÇYK sızıntı ve geçirgenlik testi, küçük MU değerlerinde lineer hızlandırıcı performansı, küçük MU monitör sistem end-effect, küçük MU simetri ve düzgünlük ve küçük alan dozimetrisi testleri incelendi. Daha sonra tedavi planlama sisteminde prostat hastası için plan olu?turuldu. Son olarak hasta planı, iyon odası ve film yanıtı yöntemi olmak üzere iki farklı yöntemle kontrol edildi.Sonuç olarak, ÇYK pozisyon doğruluğu <1 mm ve sızıntı ve geçirgenlik <%5 bulundu. Küçük MU değerlerinde lineer hızlandırıcı performansı, 5 MU'dan küçük değerler <%5 ve 5 MU ve daha büyük MU değerleri için <%2 bulundu. Monitör sistem end-effect <1 MU bulundu. Küçük MU simetri ve düzgünlük için 5 MU ve 10 MU'luk tek seferlik ı?ınlamalarda >%3 ve 5 MU×10 ve 10 MU×5 çoklu ışınlamalarda <%3 bulundu. Çe?itli iyon odaları ile yapılan ölçümler sonucunda küçük alan dozimetri doğruluğunda CC04 iyon odasının kullanılmasına karar verildi. Hasta dozimetri kontrollerinde, fantomda TPS ile hesaplanan doz ile fantomda iyon odası ile ölçülen doz arasında %1,54 fark ve film yanıt ölçümlerinde %2,61 fark bulundu. Uygulanan teknik ve donanım ile cihaz ve hasta kalite kontrolü uluslar arası protokollere uygun olarak gerçekle?tirilmi? ve test edilen cihazın bu tedavi tekniğine uygun olduğu sonucuna varılmıştır.

Özet (Çeviri)

This study examines the quality assurance of a linear accelerator in intensity modulated radiation therapy via the step-and-shoot technique, as well as the quality assurance of patient dosimeter as established by the Elekta Synergy Linear Accelerator set up in Department of Oncology of Gulhane Military Medical Academy at an energy level of 6 MV. First of all, in order to conduct intensity modulated radiation therapy via step-and-shoot technique, tests of Multileaf Collimator(MLC) Leaf Positional Accuracy, The MLC Transmission and Interleaf Leakage, The Linear Accelerator Performance for Small Monitor Unit (MU) Delivery, Monitor System End-Effect for Small MU, The Symmetry and Flatness for Small MU and small field dosimetry are run in linear accelerator. Second, after testing the quality of the linear accelerator, prostate patients are used as subjects in the treatment planning system.Finally, the patient plan is tested by two different methods: ion chamber and film response tests.Consequently, it is found that positional accuracy of MLC is <1 mm and the interleaf leakage and transmission values are <5%. Linear accelerator performance for small MU values is <%5 for <5 MU and %<2 for ?5 MU. Monitor system end-effect is measured <1 MU. Symmetry and flatness for small MU values is >3% for 5 MU and 10 MU irradiation; and <%3 for multiple irradiations of 10×5 MU and 5×10 MU. After several measurements with different ion-chambers, it is decided that CC04 ion-chamber should be used in small area dosimetry accuracy. In patient dosimetry controls, there has been 1,54% and 2,61% difference found between the calculated and measured doses for phantom and film response, respectively. The device and patient quality assurance controls are made by the techniques and hardware conforming to international protocols and it's concluded that this device is suitable for this type of treatment.

Benzer Tezler

  1. Yoğunluk ayarlı radyoterapi uygulamasında dinamik ve statik çoklu segmentli ışınlama tekniklerinin karşılaştırılması

    The comparison of dynamic and static multi segments techniques in intensity modulated radiotherapy

    BERKAN GELER

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    OnkolojiAcıbadem Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. ENİS ÖZYAR

  2. Prostat radyoterapisinde IMRT ve VMAT planlarının dozimetrik olarak incelenmesi

    Investigation of IMRT and VMAT plans as dosimetric in prostate radiotheraphy

    NECMİ ERDEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Onkolojiİstanbul Üniversitesi

    Temel Tıp Bilimleri Bölümü

    DOÇ. DR. İSMAİL ÖZBAY

  3. Statik yoğunluk ayarlı radyoterapi tekniğinin iki farklı lineer hızlandırıcı ve tedavi planlama sisteminde dozimetrik olarak değerlendirilmesi

    Evaluation of Static Intensity Modulated Radiation Therapy as dosimetric in two different linear accelerators and treatment planning system

    FATİH KARAKÖSE

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE

  4. Sol meme kanserlerinde cilt ve çok yapraklı kolimatör arasındaki mesafenin değiştirilmesiyle elde edilen volumetrik ayarlı ark terapi planlarının karşılaştırılması

    Comparison of volumetric modulated arc therapy plans obtained by changing the distance between the skin and multi-leaf collimator (MLC) in left side breast cancer

    BERAT TUĞRUL UĞURLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Onkolojiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE BECERİR

  5. 3 boyutlu baskı teknolojisi kullanılarak hastaya özgün konturlarla oluşturulan fantom tasarımı ve üretimi ile mikro-çok yapraklı kolimatör tabanlı beyin ve başboyun yoğunluk ayarlı radyoterapi planlarının kalite kontrolü

    Quality control of micro-multileaf collimator based brain and head-and-neck intensity modulated radiotherapy plans with patient-specific phantom design and production using 3D printing technology

    SERCAN SUNEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    Fiziksel Tıp ve RehabilitasyonHacettepe Üniversitesi

    Radyoterapi Fiziği Bilim Dalı

    PROF. DR. HÜSNÜ FADIL AKYOL