3 boyutlu baskı teknolojisi kullanılarak hastaya özgün konturlarla oluşturulan fantom tasarımı ve üretimi ile mikro-çok yapraklı kolimatör tabanlı beyin ve başboyun yoğunluk ayarlı radyoterapi planlarının kalite kontrolü
Quality control of micro-multileaf collimator based brain and head-and-neck intensity modulated radiotherapy plans with patient-specific phantom design and production using 3D printing technology
- Tez No: 478916
- Danışmanlar: PROF. DR. HÜSNÜ FADIL AKYOL
- Tez Türü: Yüksek Lisans
- Konular: Fiziksel Tıp ve Rehabilitasyon, Onkoloji, Radyoloji ve Nükleer Tıp, Physical Medicine and Rehabilitation, Oncology, Radiology and Nuclear Medicine
- Anahtar Kelimeler: Hastaya özgü YART KK, 3B Baskılama, KK Fantom, PLA, Kafa ve boyun neoplazmları, Neoplazmlar, Polilaktik asit, Radyasyon, Radyasyon dozajı, Radyoterapi, Tomografi-emisyon-bilgisayarlı, Üç boyutlu yazıcı, Patient-Specific IMRT QA, 3D Printing, QA Phantom, PLA, Head and neck neoplasms, Neoplasms, Polylactic acid, Radiation, Radiation dosage, Radiotherapy, Tomography-emission-computed, Three dimensional printer
- Yıl: 2017
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Radyoterapi Fiziği Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
SUNEL, S. 3 Boyutlu Baskı Teknolojisi Kullanılarak Hastaya Özgün Konturlarla Oluşturulan Fantom Tasarımı Ve Üretimi İle Mikro-Çok Yapraklı Kolimatör Tabanlı Beyin Ve Başboyun Yoğunluk Ayarlı Radyoterapi Planlarının Kalite Kontrolü. Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü Radyoterapi Fiziği Programı Yüksek Lisans Tezi, Ankara, 2017. Radyoterapide hasta tabanlı kalite kontrol (KK) işlemleri uygulanan tedavinin doğruluğu açısından büyük önem taşımaktadır. Bu çalışma kapsamında ise 3B baskı teknolojisi kullanılarak hastanın yüzey formuna sahip doku eşdeğeri fantomlar üretilip, standart KK yöntemlerine alternatif getirilmesi ve uygulanacak yöntemin kliniklerde hastaya özel YART KK'nde yaygın olarak kullanılması amaçlanmaktadır. Bu amaçla tasarlanan çalışmanın metodolojisinin ana hatları şu şekilde özetlenebilir: (i) Seçilen baş-boyun hastaların tedavisi için çekilmiş olan bilgisayarlı tomografi (BT) görüntülerinin çalışma bilgisayarına aktarılması, (ii) Bu BT'lerin“3D Slicer programı”na aktarılması ve hastanın dış yüzey formuna sahip modellemenin bilgisayar ortamında hazırlanması, (iii) Modellemenin parçalarının 3B yazıcıya aktarılması ve fantomun dış kabuğunun basımı, (iv) Dış kabukların içinin parafin mum malzeme ile doldurulması, (v) Modelin BT çekimi ve tedavi planlama sisteminde (TPS) doz hesabı, (vi) EBT3 filmlerin fantomun kesit aralarına yerleştirilerek mikro-ÇYK tabanlı YART tedavi planlarının Novalis cihazında ışınlanması, (vii) EBT3 film ve TPS'den elde edilen 2 boyutlu doz dağılımlarının gama analizi şeklindedir. Altı hastaya ait tedavi planlarının gama analizinde %3 doz farkı (DF) ve 3 mm doz mesafe uyumu (DMU), %3 DF ve 5mm DMU, %5 DF ve 3mm DMU son olarak da %5 DF ve %5 DMU kriterleri kullanılmıştır. %3/3mm kriterli gama analizinde film kenarlarındaki deformasyonlardan kaynaklı doz düşüşü dışında doz dağılımının istenen sınırlar içerisinde olduğu gözlemlenmiştir. %5/5mm kriteri kullanıldığında ise EBT3 film ile TPS verisinin uyumu ortalama olarak %95,7 (en yüksek %96.4 ve en düşük % 93.4) bulunmuştur. Başarı için eşik değeri %90 olarak kabul edilmiştir. Çalışmamız sonucunda 3B baskılama teknolojisi ile üretilen baş-boyun fantomlarının hastaya özel kalite kontrol işlemlerinde kullanılabilirliğini gösterilmiştir. Üretim aşamalarını hızlandıracak yeni teknolojilerle birlikte hasta yüzey kontur bilgisini içeren bu tür fantom uygulamaları radyoterapi merkezlerinde rutinde kullanıma başlanabilecektir.
Özet (Çeviri)
SUNEL, S. Quality control of micro-multileaf collimator based brain and head-and-neck intensity modulated radiotherapy plans with patient-specific phantom design and production using 3D printing technology. Hacettepe University Institute of Health Sciences, MSc. Thesis in Radiotherapy Physics Program, Ankara, 2017. Patient-specific quality assurance is necessary to enhance the treatment accuracy in radiotherapy facilities In this study, it is aimed to propose an alternative method to standard QA procedures by producing tissue-equivalent phantoms in the form of patient surface using 3D printing technology and thus, with time, this methods will be commonly preferred for patient-specific QA in radiotherapy clinics. The outlines of the methodology of the study designed with the aims can be summarized as: (i) Transferring the CT images of selected Head&Neck patients to workstation, (ii) Transporting the CT images to 3D Slicer software and then preparing the model with the form of patient surface in computer environment, (iii) Transporting the parts of models to 3D printer and printing the crusts of the phantom, (iv) Filling the crusts with paraffin wax, (v) Taking the CT images of model and calculating the doses in the treatment planning system (TPS), (vi) Delivering the micro-MLC based IMRT treatment plans in Novalis unit by placing the EBT3 films between the phantom slices, (vii) performing the gama analysis of 2D dose distributions acquired from EBT3 film and TPS. In the gama analyses of treatment plannings of six head&neck patients, the four sets of criteria were used: 3% dose difference (DD) & 3 mm Distance to Agreement (DTA), 3% DD & 5 mm DTA, 5% DD & 3 mm DTA, and 5% DD & 5 mm DTA. In the analysis with 3mm/3% criteria, it is observed that the dose distributions were agreed except for the dose reduction at the edge of the films induced from the deformation. When 5mm/5% criteria were chosen, the agreements between dose distributions of EBT3 film and TPS were found to be 95,7% in average (max. 96,4% and min. 93,4%). The threshold for success was accepted as 90%. Consequently, our study showed that the head&neck phantoms produced with 3D printing technology can be used for patient specific QA. By means of new technologies that accelerate the production process, 3D phantom applications including surface contour of patients can be routinely used in radiotherapy facilities.
Benzer Tezler
- Reduction of dental anxiety in children using virtual reality
Çocuklarda dental kaygının sanal gerçeklik ile azaltılması
FATMA BETÜL GÜREŞ
Yüksek Lisans
İngilizce
2021
Bilim ve Teknolojiİstanbul Teknik ÜniversitesiOyun ve Etkileşim Teknolojileri Ana Bilim Dalı (disiplinlerarası)
YRD. DOÇ. GÖKHAN İNCE
- Propolis katkılı sodyum aljinat doku iskelelerinin üç boyutlu baskı teknolojisi kullanılarak üretimi, karakterizasyonu ve antibakteriyel aktivitesinin incelenmesi
Fabrication, characterization and investigation of antibacterial activity of propolis-substituted sodium alginate tissue scaffolds using three dimensional printing technology
KÜBRA ARANCI ÇİFTÇİ
Yüksek Lisans
Türkçe
2020
BiyomühendislikYıldız Teknik ÜniversitesiBiyomühendislik Ana Bilim Dalı
DOÇ. DR. CEM BÜLENT ÜSTÜNDAĞ
DOÇ. DR. MUHAMMET UZUN
- Üç boyutlu baskı teknolojisi kullanılarak oluşturulan scalp fantomunda lateral foton elektron ve volümetrik ark tedavi modellerinin farklı dozimetrik yöntemler aracılığıyla değerlendirilmesi
Evalution of diferent dosimetric methods of lateral photon electron and volumetric arc treatment models in scalp phantom created using three dimensional printig technology
ÖZGE LAÇİN
Yüksek Lisans
Türkçe
2023
Fizik ve Fizik MühendisliğiAnkara Yıldırım Beyazıt ÜniversitesiRadyoloji Ana Bilim Dalı
PROF. DR. AYTUNÇ ATEŞ
DR. ÖĞR. ÜYESİ TAHA ERDOĞAN
- Mobil telefon kullanımına bağlı oluşan 900-1800 mhz radyo frekans dalgalarının meydana getirdiği elektromanyetik alanın iliak kanat kemik mineral yoğunluğuna etkisi
The effect of electromagnetic fields on bone mineral density of iliac bone produced by 900-1800 mhz radio frequency waves dependent on cellular phone usage
BEŞİR ANDAÇ AKSOY
Tıpta Uzmanlık
Türkçe
2006
Ortopedi ve TravmatolojiSüleyman Demirel ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF.DR. NEVRES HÜRRİYET AYDOĞAN
- Canlı vericili karaciğer nakli öncesinde,verici adaylarının karaciğer hacmi ve anatomik yapılarının bilgisayarlı tomografi verilerinden yararlanılarak elde edilen 3 boyutlu yazıcı modeli ile değerlendirilmesi
Evaluation of liver anatomical structure and volume of living donor liver transplantation candidates by way of prototipe that manufactured with 3 dimensional printer via utilizing computed tomography data before living donor liver transplantation
BELMA NALBANT
Yüksek Lisans
Türkçe
2017
Sağlık EğitimiDokuz Eylül ÜniversitesiTranslasyonel Tıp Ana Bilim Dalı
PROF. DR. İBRAHİM KEMAL ASTARCIOĞLU
ÖĞR. GÖR. TUFAN EGELİ