Farklı tedavi planlama algoritmaları kullanılarak yapılan yoğunluk ayarlı radyoterapi planlarının karşılaştırılması ve kalite kontrollerinin yapılması
Comparing and quality assurance of intensity modulated radiotherapy plans which are calculated with different treatment planning algorithms
- Tez No: 282316
- Danışmanlar: PROF. DR. FADIL AKYOL
- Tez Türü: Yüksek Lisans
- Konular: Onkoloji, Fizik ve Fizik Mühendisliği, Oncology, Physics and Physics Engineering
- Anahtar Kelimeler: Algoritma modelleme, Algoritmalar, Gama ışınları, Radyasyon dozajı, Radyasyon-iyonizan, Radyoterapi, Radyoterapi-bilgisayar yardımlı, Tedavi, Algorithm modelling, Algorithms, Gamma rays, Radiation dosage, Radiation-ionizing, Radiotherapy, Radiotherapy-computer assisted, Treatment
- Yıl: 2011
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
- Bilim Dalı: Radyoterapi Fiziği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Radyoterapide reçetelendirilen dozu hedef hacme yüksek hassasiyetle vermek büyük önem taşımaktadır. Doz dağılımlarının doğru öngörülebilmesi için tedavi planlama algoritmalarının radyasyonun doku içindeki davranışını iyi modellemesi gerekmektedir. Bu tez çalışmasında Eclipse TPS'de kullanılan Kalem Demet Evrişim Algoritması (KDEA) ve Analitik Anizotropik Algoritma (AAA) ile yapılan yoğunluk ayarlı radyoterapi (YART) planlarının karşılaştırılması ve kalite kontrollerinin (KK) yapılması amaçlanmıştır. ?Alderson Radiation Therapy? (ART) fantomun farklı bölgelerine algoritmaların davranışlarını gözlemlemek amacıyla hedef hacimler, kritik yapılar çizilmiş ve 6 MV foton enerjisinde YART planları yapılmıştır. Planlar KDEA ve AAA ile hesaplanmış ve karşılaştırılmıştır. YART planları ışınlanarak elektronik portal görüntüleme sistemi ile elde edilen portal görüntüler gama analizi ile incelenmiştir. Planların kalite kontrolleri (KK) su eşdeğeri ve heterojen fantomlarda iyon odası ve radyokromik film ölçümleri ile yapılmıştır. Radyokromik film ölçümlerinden elde edilen iki boyutlu (2B) doz dağılımları gama analizi ile incelenmiştir. Çalışmamız YART planlarında AAA'nın özellikle düşük yoğunlukta heterojenitelerin varlığında KDEA'na göre daha doğru sonuç verdiğini göstermektedir. Vücudun düşük yoğunlukta heterojenite içeren bölgelerinde yapılan YART planlarında AAA'nın tercih edilmesi gerektiği düşüncesindeyiz. Yapılan incelemelerde KDEA ve AAA'nın alan kenarlarındaki radyasyon davranışını yeteri kadar iyi modelleyemediği gözlemlenmiştir. Bu nedenle klinik uygulamalarda YART planlarının KK'nün nokta doz ölçen dozimetreler yerine radyokromik film dozimetre gibi 2B doz ölçen sistemler kullanılarak yapılması gerektiği düşüncesindeyiz.
Özet (Çeviri)
In Radiotherapy delivering the prescribed dose to the target volume accurately has a great importance. Treatment planning algorithms should model the behavior of radiation in the tissue well to predict dose distribution precisely. The aim of this study is to compare and make quality assurance (QA) tests of Intensity Modulated Radiotherapy (IMRT) plans which are calculated with Anisotropic Analytical Algorithm (AAA) and Pencil Beam Convolution (PBC) algorithm used in Eclipse TPS. To analyze behaviors of these algorithms target volumes, critical structures were drawn in the different regions of ?Alderson Radiation Therapy? (ART) phantom and IMRT plans were done with using 6 MV photon energy. After these plans were calculated with PBC and AAA, they were compared to each other. Portal images which were acquired by using electronic portal imaging device (EPID) were evaluated with gamma analysis. Quality assurance tests of IMRT plans were also performed by using water equivalent and heterogeneous phantoms, ion chambers and radiochromic films. Two dimensional (2D) dose distributions were evaluated with gamma analysis. Our study shows that AAA is more accurate than PBC particularly in heterogeneous mediums which contain low density materials. One should prefer AAA to PBC in IMRT calculations done in heterogeneous regions of human body. In the analysis of IMRT plans we observed that both PBC and AAA couldn?t model good enough radiation behavior in the edge of treatment fields. Therefore, QA of IMRT plans should be performed in clinical cases by using 2D dosimeters like radiochromic films instead of dosimeters which measure point dose.
Benzer Tezler
- Akciğer tümörlerinde yoğunluk ayarlı ark radyoterapi tekniği kullanılarak iki farklı optimizasyon algoritmasının doz dağılımına etkisinin incelenmesi
Investigation of two different doses distribution optimization algorithm in lung tumors using with intensity modulated arc radiotherapy technique
GÖRKEM ÇEVİKBAŞ
Yüksek Lisans
Türkçe
2016
Onkolojiİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
PROF. DR. HATİCE BİLGE BECERİR
- Volümetrik ark radyoterapi (VMAT) tedavilerinin hesaplanması sırasında kullanılan farklı optimizasyon yöntemlerinin karşılaştırılması
Comparison of different optimization methods used during calculation of volumetric modulated arc radiotherapy (VMAT) treatments
TUTKU ÇAĞATAY ÇARGA
Yüksek Lisans
Türkçe
2018
OnkolojiAcıbadem Mehmet Ali Aydınlar ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. MELTEM SERİN
- Yüksek enerjili x-ışını demetlerinde (6-15MV sanal kama filtreli alanlarda dozimetri parametrelerinin ölçülmesi ve tedavi planlama sistemindeki verilerle karşılaştırılması
Under high energy x-ray beams (6-15MV, the measurements of the dosimetric parameters of the fields with virtual wedges and the comparison with the datas gained from the treatment planning system
SEZGİ TURAN
Yüksek Lisans
Türkçe
2011
Fizik ve Fizik Mühendisliğiİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
PROF. DR. HATİCE BİLGE
- Fantomda, doku içine yerleştirilen protez malzemesinin eksternal ışın tedavisinde doza etkisinin farklı doz hesaplama algoritmaları ve dozimetri ile karşılaştırılması
The effect of prosthesis implant materials on doses in external beam treatment comparison with different dose calculation algorithms and dosimetry in phantom model
DOĞUKAN AKÇAY
Yüksek Lisans
Türkçe
2013
Fizik ve Fizik MühendisliğiDokuz Eylül ÜniversitesiMedikal Fizik Ana Bilim Dalı
YRD. DOÇ. DR. KADİR AKGÜNGÖR
PROF. DR. FADİME AKMAN
- Medikal lineer hızlandırıcıdaki dozimetrik ve mekanik özellikler ile tedavi planlamasında kullanılan algoritmaların hasta dozlarına etkisi
Mechanical and dosimetric propertis of medical linear acceleators and effeccts of using treatment planning algorithms on patients dose
UFUK YAZICI
Yüksek Lisans
Türkçe
2015
Fizik ve Fizik MühendisliğiRecep Tayyip Erdoğan ÜniversitesiFizik Ana Bilim Dalı
YRD. DOÇ. DR. NİLAY AKÇAY