Deri direnci değerlerinin hastalıklarda ön tanı aracı olarak kullanılması

The use of skin resistance values in the pre-diagnostic of disease

  1. Tez No: 246500
  2. Yazar: HAKAN GÜLHAN
  3. Danışmanlar: YRD. DOÇ. DR. EYYÜP GÜLBANDILAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Deri Direnci Ölçüm Aleti, SRR, Bel Ağrısı, VAS, Galvanik deri cevabı, Skin Resistance Measuring Instrument, SRR, Waist ache, the VAS, Galvanic skin response
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: Dumlupınar Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Hastalıkların tedavisinde erken teşhis çok önemlidir. Hastalığa bir isim koyabilmek için çeşitli tanı araçları kullanılmaktadır. Bu tanı araçları ya kan tahlilin de olduğu gibi enjeksiyonla ya da hastalıklı organdan parça alınarak teşhis yapılmaktadır. Burada en önemli konu yöntemin basitliği ve bilgi alınırken hastaya cerrahi müdahale gerektirmemesidir (non-invasive). Bu nedenle, tez çalışmasında non-invasive bir yöntem olan deri direnci ölçüm cihazının ve yazılımının geliştirmesi hedeflenmiştir.Geliştirilen cihazın ölçümlerinin kontrolü için değerleri bilinen dirençler üzerinden ölçümler yapılarak, kalibrasyon eğrileri çizilmiştir. DC gerilimde yapılan ölçümlerde %99.96 korelasyon bulunurken, AC gerilimde yapılan ölçümlerde %99.98 korelasyon bulunmuştur. Benzer korelasyon, cihazın seri portundan alınan direnç değerlerinin okunduğu bilgisayar yazılımında da görülmüştür.Geliştirilen cihaz, bel ağrılarının teşhisinde kullanılmıştır. Dumlupınar Üniversitesi Tıp Fakültesi Fizik Tedavi ve Rehabilitasyon birimine başvuran 2'si erkek, 1'i bayan toplam 3 hasta üzerinde deri direnci ölçümü yapılmıştır. Ayrıca bel ağrısı rahatsızlığı bulunmayan 4'ü erkek, 4'ü bayan 8 kişi kontrol gurubu olarak kullanılmıştır. Öncelikle hastaların visual analog skala (VAS) değerleri belirlenmiş ve aynı zamanda hastaların tedavi öncesi 1. ve 3. dakikalarda AC ve DC deri direnci değerleri ölçülmüştür. Tedavi sonrasında aynı hastaların tekrar deri direnci değerleri ölçülerek kayıt altına alınmıştır. Benzer ölçümler kontrol grubuna da yapılmıştır. Deney grubunun tedavi öncesi ve tedavi sonrası ölçümleri arasında fark gözlemlenemezken, deney grubu ile kontrol grubu ölçümleri arasında istatistiksel olarak anlamlı farklar bulunmuştur (P<0,05).Bu tez çalışmasıyla geliştirilen deri direnç ölçümü cihazı ve bilgisayar yazılımı teşhis amacıyla başarılı bir şekilde kullanılabilecektir. Ayrıca geliştirilen cihaz ve yazılım iç organlar üzerinde de direnç ölçümleri yaparak teşhis amacıyla kullanılabilecektir.

Özet (Çeviri)

In the treatment of diseases early diagnosis plays an important role. In order to identify the disease, various diagnosis tools are used. These diagnosis tools may identify the disease by blood sample test like injection or biopsy. The most important issue in this process is the simplicity of the method and does not necessitate any surgical operation e.g. being non-invasive. Therefore in this thesis, a tool and software is developed with the aim of measuring the skin resistance by using a non-invasive method.In order to test and verify the results of the developed tool, the values produced by the device are compared with the actual values. The measurements under the DC voltages are correlated to 99.96% and under the AC voltage measurements are correlated to 99.98%. Similar results are seen by the computer software.The device which has been developed is tested in the diagnosis of muscle pain. For this aim 2 men and 1 women in total of 3 patients? skin resistance measurement are performed at the Faculty of Medicine, Physical Therapy and Rehabilitation unit of Dumlupinar University. Also another group which does not have any muscle disorders consisting of 4 men and 4 women in total of 8 people was used as a control group. Initially, patients' visual analogue scale (VAS) values were determined before the treatment and meanwhile, AC and DC resistance values of the skin in the first and third minutes are measured. The measurements are carried out after the treatment on the same patients. The similar measurements are performed for the control group. Although no differences were observed between the measurements before and after treatment of the experiment group; the measurements of control and experiment group were found with statistical significance (P<0.05).In this thesis with the developed skin resistance measuring device and computer software, the diseases may successfully be diagnosed. The developed device and software may also be used on the internal organs for diagnosis purposes.

Benzer Tezler

  1. Prostat adenokarsinomlarında psa değerlerinin gleason skor ve klinik evre ile ilişkisi

    The relation between psa and gleason score and clinical phase in prostate adenocarsinoma

    HACI HASAN ESEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2005

    PatolojiSelçuk Üniversitesi

    Patoloji Ana Bilim Dalı

    PROF.DR. MUSTAFA CİHAT AVUNDUK

  2. Hidradenitis suppurativa hastalarında aterosklerozun karotis ve femoral arter intima-media kalınlığı ile değerlendirilmesi

    Evaluation of atherosclerosis by carotid and femoral artery intima-media thickness in patients with hidradenitis suppurativa

    İREM DİLEM ÖZCANLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    DermatolojiSağlık Bilimleri Üniversitesi

    Deri ve Zührevi Hastalıklar Ana Bilim Dalı

    PROF. DR. FİLİZ CEBECİ KAHRAMAN

  3. Modeling of magnetic nanoparticle concentration from CT images for cancer therapy using hyperthermia

    Hipertermi ile kanser tedavisi için manyetik nanoparçacıkların konsantrasyonlarının bilgisayarlı tomografi kullanılarak modellenmesi

    RASTIN ALABAF

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Biyomühendislikİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. İSA YILDIRIM

  4. Liken planuslu hastalarda kardiyovasküler riskin belirlenmesi

    Determination of cardiovascular risk in patiens with lichen planus

    KÜBRA YÜCE ATAMULU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    DermatolojiErciyes Üniversitesi

    Deri ve Zührevi Hastalıklar Ana Bilim Dalı

    PROF. DR. AYTEN FERAHBAŞ

  5. Kalp yetmezliğin hepatik ve renal doppler bulguları

    Finding of renal and hepatic doppler in heart failure

    SÜLEYMAN HİLMİ KONAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Radyoloji ve Nükleer TıpHarran Üniversitesi

    Radyoloji Ana Bilim Dalı

    YRD. DOÇ. DR. SEMA YILDIZ