Geri Dön

Otolog dolgu maddesi olarak plazmanın jel formunun (Plazmajel) kırışıklıklara uygulandıktan sonra süreye göre etkinlik ve toleransının değerlendirilmesi

Evaluation of efficiency and tolerance of gel form of plasma (Plasmagel), following application in facial wrinkles

  1. Tez No: 243130
  2. Yazar: HANDE AKINCI
  3. Danışmanlar: PROF. DR. NİLGÜN ATAKAN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Dermatoloji, Dermatology
  6. Anahtar Kelimeler: otolog, dolgu maddesi, plazma, autologous, filler, plasma
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Dermatoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Plazmajel kişinin kendi kanından hazırlanan otolog dolgu maddesidir. Bu çalışmanın amacı yüz kırışıklıklarında Plazmajel'in süreye göre etkinlik ve toleransını değerlendirmektir. Çalışmamıza toplam 30 kadın gönüllü katıldı. Gönüllüler uygulama öncesi 15 kişilik iki gruba ayrıldı. Birinci gruba 1 kez, ikinci gruba ise 1 ay arayla 2 kez uygulama yapıldı. Gönüllülerin uygulama öncesi ve sonrası, 1. ve 3. aylarda fotoğrafları çekildi. Uygulamadan 1 ay ve 3 ay sonraki değerlendirme için ?Plazmajel'in Süreye Göre Etkinlik Skoru? oluşturuldu. Bu skora göre, ?etkinlik kayboldu?= < %10, ?etkinlik azalarak devam ediyor?= % 10-49, ?etkinlik belirgin olarak devam ediyor?= % 50-100 şeklinde derecelendirildi. Kırışıklık bölgeleri ?Fitzpatrick Kırışıklık Skalası'na? göre hafif, orta, derin şeklinde sınıflandırıldı. Çekilen fotoğraflar karşılaştırılarak iki araştırmacı tarafından yapılan değerlendirme sonuçlarının ortalamaları alındı. Ayrıca ?Gönüllü Anket Formu? gönüllüler tarafından dolduruldu. Çalışma sonuçlarına göre, gönüllülerin yaş ortalaması 48.87±4.55 yıldı. Birinci uygulamadan 1 ay sonraki değerlendirmede 16 gönüllüde (% 53.3) Plazmajel'in etkinliği % 1-49 oranında, ikinci gruba yapılan ikinci uygulamadan 1 ay sonraki değerlendirmede, 9 gönüllüde (% 60) etkinliğin % 1-49 oranında, 5 gönüllüde (% 33.3) etkinliğin % 50-100 oranında devamlılık gösterdiği saptandı. Grup 2'nin ikinci uygulamasından 3 ay sonraki değerlendirmesinde 5 gönüllüde (% 33.3) etkinlik %1-49 oranında devam ederken, grup 1'in 3 ay sonraki değerlendirmesinde etkinliğin kaybolduğu gözlendi. Grup 1 ve 2'nin süreye göre uygulama etkinlikleri karşılaştırıldığında istatistiksel olarak anlamlı fark bulundu (p<0.05). Plazmajel uygulanan bölgelerden glabella ve nazolabial oluk için kırışıklık derinliği ile süreye göre uygulama etkinliğinin karşılaştırılmasında istatistiksel bir fark saptanmadı (p>0.05). Anket sonuçlarına göre, gönüllülerin %94.4'ü Plazmajel'i güvenilir buldukları için tercih etmekteydi. Bu sonuçlara göre Plazmajel güvenilir bir üründür, ikinci uygulama etkinliği arttırmaktadır.

Özet (Çeviri)

Plasmagel is an injectable autologous soft tissue filler, extracted from one?s own blood. The aim of this study is to evaluate efficiency and tolerance of Plasmagel regarding duration of application. Thirty women volunteers were included in the study, aged 40-60 years (mean 48.8 ? 4.5 years). The patients divided into two goups before application. Plasmagel was applied once in the first group and twice in the second group at first and third month after application. Before and after the applications digital photographs of the whole group were taken. ?Efficiency score of Plasmagel regarding duration of application? was set in order to evaluate the efficiency at first and third month of application. The score was defined as; ?disappearence of efficiency = < 10 %, decreased efficiency = 10-49 %, significantly efficient = 50-100 %?. Areas of wrinkles were scored as shallow, medium and deep according to the ? Fitzpatrick Wrinkles Scale?. Photographs were evaluated independently by two researcher and average of the scores were recorded. Volunteers were asked to fill the ?Volunteers Questionnaire Forms?. The study revealed that at the first month of application, the efficiency was 10-49 % in 16 of 30 volunteers. However, in the second group who had application time points 1 and 3 months, efficiency score was 10-49 % ve 50-100 % in 9 volunteers ( 60 %) and 5 volunteers (33.3 %) respectively. Evaluation 3 months after the second application of group 2, it was shown that efficiency still continued 10-49 % in 5 volunteers (33.3 %) whereas efficiency disappeared totally in the first group at the same time point. A statistically significant difference (p<0.05) was detected when the scores of two group were compared. However, no statistically difference (p>0.05)was found regarding the wrinkle width and efficiency scores of wrinkle areas (glabella versus nasolabial sulcus). Based on the questionnaire records 94.4 % of the volunteers have declared that Plasmagel is safe and they prefer to use. We conclude that Plasmagel is a safe product and second application increases efficiency.

Benzer Tezler

  1. OTOLOG PLAZMA JELİN GÜVENLİ VE UCUZ BİR DERMAL DOLGU MATERYALİ OLARAK KULLANIMININ GÜNDEME GETİRİLMESİ: SIÇAN MODELİNDE TİCARİ HYARULONİK ASİT BAZLI DERMAL DOLGULAR VE OTOLOG YAĞ GREFTİ İLE KARŞILAŞTIRILMASI

    THE EVALUATION OF THE USE OF OTOLOG PLASMA GEL AS A SAFE AND CHEAPER DERMAL FILLING MATERIAL: COMPARISON WITH COMMERCIAL HYARULONIC ACID BASED DERMAL FILLINGS AND OTOLOG FAT GRAFT IN THE RAT MODEL

    OĞUZ ATAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    Plastik ve Rekonstrüktif CerrahiSağlık Bilimleri Üniversitesi

    Plastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı

    DOÇ. DR. NEZİH SUNGUR

  2. Alıcı sahaya preoperatif uygulanacak mikroporasyon tekniğinin yağ grefti sağkalımına etkisi

    The effect of preoperative microporation of the recipient site on fat graft survival

    BİLLUR SEZGİN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Plastik ve Rekonstrüktif CerrahiGazi Üniversitesi

    Plastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı

    DOÇ. DR. SELAHATTİN ÖZMEN

  3. Otolog kondüsyonel serumun sıçanlardaki yağ grefti yaşayabilirliğine etkisinin plateletten zengin plazma – yağ grefti kombinasyonu ile kontrollü karşılaştırılması

    Controlled comparison of the effects of autologous conditioned serum (ACS) and platelet-rich plasma (PRP) on the fat graft survival in rats

    GÖKAY BAYKARA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    Plastik ve Rekonstrüktif CerrahiSağlık Bilimleri Üniversitesi

    Plastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı

    DOÇ. DR. NEZİH SUNGUR

  4. Yüzdeki atrofik nedbe ve yaşlanmaya bağlı kırışıklıkların tedavisinde otolog fibroblast kullanımı

    Clinical application of autologous fibroblasts for the treatment of facial rhytids anddermal depressions

    BURCU ÇELET ÖZDEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2005

    Plastik ve Rekonstrüktif Cerrahiİstanbul Üniversitesi

    Plastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı

    PROF.DR. ATİLLA ARINCA