Geri Dön

Hollow fiber membran biyoreaktörde aerobik şartlarda fenol giderimi

Removal of phenol under aerobic conditions in a hollow fiber membranebioreactor

  1. Tez No: 155568
  2. Yazar: HAKAN BUDAK
  3. Danışmanlar: Y.DOÇ.DR. ALPER NUHOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Fenol giderimi, biyoreaktör, membran, aerobik fenol giderimi, sürekli reaktör, Phenol removal, bioreactor, membrane, aerobic phenol degradation, continuous reactor
  7. Yıl: 2004
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Y. Lisans Tezi HOLLOW FİBER MEMBRANBİYOREAKTÖRDE AEROBİK ŞARTLARDA FENOL GİDERİMİ Hakan BUDAK Atatürk Üniversitesi Fen Bilimleri Enstitüsü Çevre Mühendisliği Anabilim Dalı Danışman: Yrd. Doç. Dr. Alper NUHOĞLU Önemli bir endüstriyel kirletici olan fenolün çapraz akışlı membranbiyoreaktörde arıtımı incelenmiştir. Aerobik şartlarda sürekli rejimde işletilen reaktör 1.9 L hacmindedir. Çalışmada kullanılan biyokütle Erzincan kenti Atıksu Arıtma Tesisi Havalandırma Havuzu'ndan getirilmiştir ve fenol içeren ortamda üretilmiştir. Çalışma boyunca sıcaklık 26±l°C'de, pH 6-7 civarında sabit tutulmuş ve çamur yaşı 20 gün olarak seçilmiştir. Reaktöre 0.36-7.2 g/gün aralığında değişen fenol yükleri uygulanmış ve uygulanan yüklemelere göre sistemden %51-99 arasında değişen fenol giderim verimleri elde edilmiştir. Mikroorganizma konsantrasyonlarının artan fenol konsantrasyonlarıyla değişimi izlenmiştir. 6.3 saat seçilen hidrolik bekleme süresi ve 0.72 g/gün'lük fenol yüklemesi için giderim verimi %99 bulunmuştur. Daha sonra hidrolik bekleme süresi 3.2 saate indirilmiş ve aynı fenol yüklemesine karşı giderim verimi incelenmiştir. 1460 mg/L AKM varlığında fenol konsantrasyonu 250 mg/L'ye çıkarılmış ve fenol giderimi %97 hesaplanmıştır. En yüksek yükleme değeri olan 7.2 g/gün (Fo^OO mg/L) fenol yüklemesine kadar AKM'de sürekli bir artış belirlenmiştir. Bu yükleme değerinden sonra çamur konsantrasyonunun birbirini izleyen iki gün düştüğü saptanmıştır. Fenol giderim verimi %53'e düştüğünde 7.2 g/günTük yükleme sonlandırılmıştır. 2004, 41 sayfa

Özet (Çeviri)

ABSTRACT Master Thesis REMOVAL OF PHENOL UNDER AEROBIC CONDITIONS IN A HOLLOW FIBER MEMBRANEBIOREACTOR Hakan BUDAK Atatürk University Graduate School of Natural Applied Sciences Department of Environmental Engineering Supervisor: Asst.Prof.Dr. Alper NUHO?LU The removal of an important industrial pollutant; phenol was investigated. The volume of reactor operated under aerobic conditions was 1.9 L. Biomass used in this study was taken from the aeration tank of Wastewater Treatment Plant of Erzincan city and acclimated to the medium including phenol. During the study temperature and pH was kept constant about 26±1°C and 6-7, respectively and solid retention time (SRT) was chosen as 20 days. Phenol loading rates changing between 0.36-7.2 g/day applied to the reactor and removal efficiencies varying between 51-99% was obtained corresponding to these loading rates. The change of MLSS with enhanced phenol concentrations was observed. For hydraulic retention time (HRT) of 6.3 h and 7.2 g/day phenol loading the removal rate was found as high as 99%. Then HRT was reduced to 3.2 h and the change of removal rate was determined against same phenol loading. Phenol concentration increased up to 250 mg/L for MLSS of 1460 mg/L and phenol removal rate was found 97%. Up to the highest loading rate of 7.2 g/day (Fq=500 mg/1), a continuous increase in MLSS was determined. After this loading rate it was seen that sludge concentration reduced in consecutive two days. When the phenol removal rate decreased to 53%, loading rate of 7.2 g/day was abandoned. 2004, 41 pages

Benzer Tezler

  1. Equilibrium studies on the reactive extraction of lactic acid from fermentation broth

    Laktik asidin fermantasyon ortamında reaktif özütlenmesi ile ilgili denge çalışmaları

    BAŞAK AÇAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2003

    Kimya MühendisliğiOrta Doğu Teknik Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF. DR. TÜRKER GÜRKAN

  2. Hemodiyaliz amaçlı poliakrilonitril membranlar hazırlanması

    Preparation of polyacrylonitrile membranes for hemodialysis application

    GAMZE BEHMENYAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Kimya Mühendisliğiİstanbul Teknik Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BİRGÜL TANTEKİN (ERSOLMAZ)

  3. Dye affinity hollow fibers for interferon separation

    İnterferon ayrılması için boya afinite hollow fiberler

    ELİF ERKAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2003

    KimyaHacettepe Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. ADİL DENİZLİ

  4. Membranlarla gaz ayırma

    Gas separation by membranes

    İSMAİL BÜLBÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    Kimya Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ.DR. BİRGÜL TANTEKİN ERSOLMAZ