Geri Dön

Tamamıyla katı-hal kompozit kalsiyum seçici elektrot ve potansiyometrik davranışı

All solid-state composite calcium selective electrode and its potentionmetric performances

  1. Tez No: 155044
  2. Yazar: NEZAKET SARIBOĞA
  3. Danışmanlar: Y.DOÇ.DR. ADEM ASAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: İyon-Seçici Elektrot, Katı-Hal Elektrot, Kompozit elektrot, kalsiyum iyonofor IV, ETH 5234, Ion-Selective Electrode, Solid-State Electrode, Composite Electrode, Ca ionophore IV, ETH 5234
  7. Yıl: 2004
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

11 TAMAMIYLA KATI-HAL KOMPOZİT KALSİYUM SEÇİCİ ELEKTROT VE POTANSİYOMETRİK DAVRANIŞI ÖZET Bu çalışmada kalsiyum iyonofor IV (ETH 5234, N,N-Dicyclohexyl-N',N'-dioctadecyl- diglycolic daimide; N,N-Dicyclohexyl-N'-N'-dioctadecyl-3-oxapentanediamide) aktif maddesi kullanılarak tamamıyla katı-hal kompozit kalsiyum iyon-seçici elektrot hazırlandı. Elektrodun potansiyometrik performanslan bilgisayarlı bir ölçüm sisteminde araştırıldı. Hazırlanan bütünüyle katı hal kompozit kalsiyum iyon-seçici elektrodun ana iyon çözeltisine karşı her 1 0 kat konsantrasyon değişimi için 24 mV potansiyel değişimi gösterdiği, cevap zamanının oldukça kısa (yaklaşık 10 s) ve kullanım süresinin uzun (en az 8-10 hafta) olduğu belirlendi. Hazırlanan elektrot Ixl0_1-lxl0“5 mol.L”1 konsantrasyon aralığında ana iyon çözeltisine karşı doğrusal davranış sergilemekteydi. Elektrodun ana iyon yamnda girişim yapan iyonlara karşı seçicilik katsayıları“ayrı çözelti metodu”ile hesaplandı ve kalsiyum iyonofor IV ile hazırlanan elektrodun özellikle Ca2+ iyonuna karşı oldukça seçici olduğu sonucuna varıldı. Ayrıca, geliştirilen elektrot, akış-enjeksiyon analiz (Fi A) sisteminde dedektör olarak kullanılarak çeşitli süt ve yoğurt örneklerindeki Ca2+ iyonunun tayini başarıyla gerçekleştirildi.

Özet (Çeviri)

Ill ALL SOLID-STATE COMPOSITE CALCIUM SELECTIVE ELECTRODE AND ITS POTENTIOMETRIC PERFORMANCES ABSTRACT In this work, a solid-state composite calcium ion-selective electrode was prepared by using calcium ionophore IV (ETH 5234, N,N-Dicyclohexyl-N',N'-dioctadecyl-diglycolic daimide;N,N-Dicyclohexyl-N'-N'-dioctadecyl-3-oxapentanediamide). The potentiometric performance characteristics of the electrode was examined with a computerized measuring system. The prepared electrode almost exhibited 24 mV potential difference per decade, short response times (approximately 10 s), long life times (at least 8-10 week), a linear response between 1.10“1-1.10”5 mol.L“1 solutions against main ion. Selective cofficients of the electrodes for againts interfering ions were calculated by ”separate solution method" and while electrodes prepared with calcium ionophore IV compound showed very high selectivity toward Ca2+ ion. Besides, prepared electrode, used as dedector in flow-injection analyse (FIA) system in some milk and yogurt samples successfully.

Benzer Tezler

  1. Mammografi ve ultrasonografinin meme kanseri tanısında yeri

    Başlık çevirisi yok

    CEBBAR ÇALIŞKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Genel CerrahiGata

    Genel Cerrahi Ana Bilim Dalı

  2. Matris lie grupları üzerine

    Başlık çevirisi yok

    RIFAT GÜNEŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Matematikİnönü Üniversitesi

    Matematik Ana Bilim Dalı

    YRD. DOÇ. DR. NURİ KURUOĞLU

  3. Balıkesir tavukçuluk işletmelerinin yapısal özellikleri üzerinde bir inceleme

    Başlık çevirisi yok

    MEHMET TOSUN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    ZiraatEge Üniversitesi

    Zootekni Ana Bilim Dalı

  4. Kemalpaşa etlik piliç işletmelerinin teknik ve ekonomik yönden incelenmesi

    Başlık çevirisi yok

    HAYRİ TUNA YÜKSELEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    ZiraatEge Üniversitesi

    Zootekni Ana Bilim Dalı

    DOÇ. DR. ÇETİN KOÇAK