Geri Dön

Deri endüstrisi atık sularındaki kromun mikrobial yolla uzaklaştırılması

Removal of chromium from leather industry waste water by using microbial mass

  1. Tez No: 131378
  2. Yazar: NUR KOÇBERBER
  3. Danışmanlar: PROF. DR. GÖNÜL DÖNMEZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyoloji, Biology
  6. Anahtar Kelimeler: Krom, biyobirikim, mikroorganizma, atıksu, deri endüstrisi, Atık su, Endüstriyel atıklar, Mikroorganizmalar, Chromium, bioaccumulation, microorganism, waste water, leather industry, Industrial wastes, Microorganisms
  7. Yıl: 2003
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Yüksek Lisans Tezi DERİ ENDÜSTRİSİ ATKSULARINDAKİ KROMUN MİKROBİYEL YOLLA UZAKLAŞTIRILMASI NnrKOÇBERBER Ankara Üniversitesi Fen Bilimleri Enstitüsü Biyoloji Anabilim Dab Danışman: Prof. Dr. Gönül DÖNMEZ Krom ve tuz içeren deri endüstrisi atıksulannuı arıtımında kullanım potansiyeline sahip karışık ve saf kültürlerin elde edildiği tez çalışmasında, krom ve tuz içeren ortamlarda mikroorganizmaların krom biyobirikim kapasitelerine farklı besiyerlerinin, pH değerlerinin, NaCI ve Cr(VI) konsantrasyonlarının etkisi incelenmiştir. Karışık kültürlerle Aktif Çamur( AÇ), Nutrient Broth(NB) ve Melash(M) besiyerlerinde yapılan denemelerde CrÇVT) biyobirikim verimi pH 8'de % 4 (w/v) NaCI ve yaklaşık 50 ppm CrCVI) konsantrasyonunda M besiyerinde % 99.1, NB besiyerinde % 89.0 ve AÇ besiyerinde % 35.0 olarak belirlenmiştir. Yaklaşık 100 ppm CtÇVT) ve % 0, 2, 4 ve 6 (w/v) NaCI içerefi pH'ı 7, 8 ve 9'a ayarlanan NB ve M besiyerlerinde denenen tüm tuz konsantrasyonlarında NB besiyerinde pH 9'da en yüksek Cr(Vr) biyobirikimi elde edilirken, M besiyerinde % 2 ve 6 (w/v) NaCI konsantrasyonlarında pH 8'de, % 4 (w/v) NaCI konsantrasyonunda ise pH 9'da en yüksek biyobirikim elde edilmiştir. Artan konsantrasyonlarda CrÇVT) içeren (~ 25-300 ppm) NB besiyerinde en yüksek CrÇVT) biyobirikimi pH 9'da % 4 NaCI konsantrasyonunda, pH 7 ve 8'de ise % 6 (w/v) NaCI konsantrasyonunda belirlenmiştir. Yaklaşık 25>-500 ppm CrCVT) içeren M besiyerinde pH 8'de % 4 (w/v) NaCI konsantrasyonunda pH 7 ye 9'da ise % 6 (w/v) NaCI konsantrasyonunda karışık kültür yüksek oranda CrÇVT) biyobirikimi yapmıştır. NB besiyerinde karışık kültürlerin yaklaşık 300 ppm CrÇVT) konsantrasyonundan daha yüksek konsantrasyonlarda gelişmediği belirlenmiştir. NB besiyeri ile yapılan çalışmalarda yaklaşık 300 ppm CrÇVT) konsantrasyonunda % 2 (w/v) NaCI içeren besiyerinde pH 9'da % 27.6; % 4 (w/v) NaCI içeren besiyerinde pH 9'da % 39.9 ve % 6 Çw/v) NaCI içeren besiyerinde ise pH 8'dö % 4İ3 verimle ÇrÇVT) biyobirikimi elde edilmiştir. Yaklaşık 500 ppm CrÇVT) ve % 2 (w/v) NaCI içeren İVİ besiyerinde pH 8'de (% 77.4), % 4 Çw/v) NaCI içeren besiyerinde pH 8'de (% 100.0) ve % 6 (w/v) NaCI içeren besiyerinde pH 9'da Ç%90.6) CrÇVT) biyobirikimi en yüksek değerlere ulaşmıştır. Karışık kültürlerden izole edilen beş saf kültürle NB ve M besiyeri ile yapılan çalışmalarda 98.9 ppm CrÇVT) içeren M besiyerinde ÇpH 8, % 4 Çw/v) NaCI) % 99.3 verimle CrÇVT) biyobirikimi yapan bir saf kültür elde edilmiştir. Bu kültürle farklı tuz ve CrÇVT) konsantrasyonlannda M besiyerinde yapılan denemelerde % 2 (w/v) NaCI konsantrasyonunda (pH 8) 43 1.0 ppm CrÇVT) konsantrasyonunda % 99.7; % 4 Çw/v) NaCI konsantrasyonunda (pH 9) 527.6 ppm CrÇVT) konsantrasyonunda % 99.7 ve % 6 Çw/v) NaCI konsantrasyonunda (pH 8) 456.3 ppm CrÇVT) konsantrasyonunda % 79.8 verimle CrÇVT) biyobirikiminin olduğu bulunmuştur. 2003, 59 sayfa

Özet (Çeviri)

ABSTRACT Master thesis REMOVAL OF CHROMIUM FROM LEATHER INDUSTRY WASTE WATER BY USING MICROBIAL BIOMASS NurKOÇBERBER Ankara University Graduate School of Naturel and Applied Sciences Department of Biology Supervisor: Prof. Dr. Gönül DÖNMEZ The thesis in which mixed and pure cultures that have a potential to be used in the treatment of leather industry waste water containing chromium and salt are obtained, the effects of different media, pH values, concentrations of NaCI and Cr(Vi) to the chromium bioaccumulation capacity of the microorganisms in media containing chromium and salt are examined. In the trials made with Active Sludge{AS), Nutrient Broth(NB) and MolassesÇM) media with mixed cultures, the bioaccumulation yield was determined as 99.1 % in M medium, 89.0 % in NB medium and 35.0 % in AS medium at pH 8, 4 % (w/v) NaCI and approximately 50 ppm Cr(VI) concentration. In NB and M medium which was examined in all salt concentrations, in NB medium containing approximately 100 ppm Cr(VI) and 0, 2, 4 and 6 % (w/v) NaCI with pH 7, 8 and 9, the highest Cr(VT) bioaccumulation was obtained, but oil the other hand in M medium containing 2 % (w/v) and 6 % (w/v) NaCI at pH 8 and 4 % (w/v) of NaCI concentrations at pH 9 was yielded the highest Cr(VI) bioaccumulation. In NB medium containing increasing concentrations of Cr(VT) the highest Cr(VI) bioaccumulation at pH 9 was determined at 4 % (w/v) NaCI concentration, but at pH 7 and 8 the highest bioaccumulation was determined at 6 % (w/v) NaCI concentration. In M medium containing approximately 25- 500 ppm Cr(Vr), high Cr(VI) bioaccumulation at pH 8 with 4 % (w/v) NaCI concentration and at pH 7 and 9 with 6 % (w/v) NaCI concentration was obtained by mixed culture. In NB medium containing chromium concentrations approximately higher than 300 ppm, no growth observed with mixed cultures. In the studies performed with NB medium containing approximately 30Û ppm Cr(VT), at 2 % (w/v) NaCI, pH 9 27.6 % Cr(VI) bioaccumulation; at 6 % (w/v) NaCI, pH 8 43.3 % Cr(VI) bioaccumulation is obtained. In M media containing approximately 50Ö ppm Cr(VT), at 2 % (w/v) NaCI, pH 8 (77.4 %), at 4 % (w/v) NaCI, pH 8 (100 %), arid at 6 % (w/v) NaCI, pH 9 (90.6 %) Cr(VI) bioaccumulation reached to the highest values. In studies performed with five pure cultures isolated from mixed cultures in NB and M media, a pure culture which bioaccumulates with 99.3 % yield in M medium containing 98.9 ppm Cr(VI) (4 % (w/v) NaCI at pH 8) was obtained. In experiments with M medium with different salt and Cr(VI) Concentrations, the media having 2 % (w/v) NaCI (pH 8) and 431.0 ppm Cr(VI), bioaccumulation was 99.7 %; at 4 % (w/v) NaCI (pH 9) and 527.6 ppm Cr(VT) it was 99.7 % and at 6 % (w/v) NaCI (pH 8) and 456.3 ppm Cr(VI) it was 79.8 %. 2003, 59 Pages

Benzer Tezler

  1. Deri sanayii atık sularından kromun doğal zeolit (Klinoptilolit) yardımıyla adsorbsiyon yöntemi kullanılarak giderimi

    The Removal of chromium from leather industry waste waters by adsorbsion method using natural zeolite (Clinoptilolite)

    REMZİ TOPRAK

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Çevre MühendisliğiHacettepe Üniversitesi

    Çevre Bilimleri Ana Bilim Dalı

    PROF. DR. İSMAİL GİRGİN

  2. Deri endüstrisi atık sularında magnezyum amonyum fosfat çöktürmesinin biyolojik arıtılabilirliğe etkisi

    Magnesium ammonium phosphate precipitation in tannery wastewaters and its effect on biological tretability

    GÜLSÜM EMEL ZENGİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. OCAY TÜNAY

  3. Deri atık suyunun biyolojik arıtımında rol oynayan bazı mikroorganizmaların saptanması

    Başlık çevirisi yok

    NURCAN ALTUNKAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    1990

    MikrobiyolojiEge Üniversitesi

    Biyoloji Ana Bilim Dalı

    PROF. DR. SANVER EKMEKÇİ

  4. Deri endüstrisi atık sularında magnezyum amonyum fosfat çöktürmesi ile azot giderimi

    Nitrogen removal magnesium amonyum phosphote preciprtotion in tannery wastewater

    MEHMET ŞÜKRÜ ÇETİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. OKAY TÜNAY

  5. Deri endüstrisi arıtılmış atıksularındaki KOİ'nin ozon oksidasyonu ile giderimi

    COD removal in biological treatment effluent of tannery wastewater by ozone oxidation

    ZAİM BERKER YELMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. OLCAY TÜNAY