Nanodot OSLD sisteminin dozimetrik karakteristiközelliklerinin klinik elektron ve foton demetleri içinincelenmesi
Investigation of the dosimetric characteristics of the nanodotOSLD system for clinical electron and photon beams
- Tez No: 1011190
- Danışmanlar: PROF. DR. MUSTAFA HİCABİ BÖLÜKDEMİR, DOÇ. DR. SERAP ÇATLI DİNÇ
- Tez Türü: Yüksek Lisans
- Konular: Radyasyon Onkolojisi, Fizik ve Fizik Mühendisliği, Radiation Oncology, Physics and Physics Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Nükleer Bilimler Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu tezin amacı Al2O3 kristalinin dozimetrik özelliklerinin ve in-vivo doz doğrulaması için klinik ortamda kullanılabilirliğinin araştırılmasıdır. Bu çalışma NanoDot OSLD'nin klinik ortamlarda güvenle kullanılabilmesi için gerekli olan temel performans testlerini ve potansiyel düzeltme faktörlerinin belirlenmesini kapsamaktadır. Bu kapsamda, farklı foton (6-25 MV) ve elektron (3-12 MeV) enerjileri kullanılarak sistemin; doz-cevap lineerliği, gantri açısı, alan boyutu, doz hızı, enerji ve kaynak-cilt mesafesi bağımlılığı ile sinyal sönümleme etkisi test edilmiştir. Ölçümler katı su ve balmumu fantomlar kullanılarak yapılmış ve sonuçlar microSTAR okuyucu ile değerlendirilmiştir. Sonuçlar, NanoDot OSLD'lerin 0-500 cGy klinik doz aralığında mükemmel bir lineerlik sergilediğini göstermiştir. Dozimetrelerin Gantri açısı, alan boyutu ve doz hızından önemli ölçüde etkilenmediği saptanmıştır. Bu özellikler, dozimetreyi Yoğunluk Ayarlı Radyoterapi gibi modern ve karmaşık tedavi teknikleri için uygun bir ölçüm aracı olduğu kanısına varılmıştır. Buna karşın sistemin foton ve elektron demetlerine karşı belirgin bir enerji bağımlılığı olduğu gözlenmiştir, bu durum farklı enerjilerde doğru doz ölçümü yapılabilmesi için enerjiye özel düzeltme faktörlerinin kullanımını gerekli kılmaktadır. Ayrıca 240 günlük takip sürecinin sonunda dozimetrelerde %6'dan daha az sinyal sönümlemesi tespit edilmiştir, bu sonuç sistemin yüksek kararlılığa sahip olduğunu ortaya koymaktadır. Sonuç olarak NanoDot OSLD sistemi klinik radyoterapi uygulamalarında güvenilir in-vivo dozimetri aracı olarak kullanılabilir.
Özet (Çeviri)
This thesis aims to investigate the dosimetric properties and clinical applicability of NanoDot optically stimulated luminescence dosimeters (OSLDs) containing Al₂O₃ crystals for invivo (patient-based) dose verification in clinical settings. This study encompasses the fundamental performance tests necessary for the safe use of NanoDot OSLDs and the evaluation of potential correction factors. In this context, the system's performance was tested for its dose-response linearity and its dependence on gantry angle, field size, dose rate, energy, and source-skin distance (SSD), as well as its signal fading effect, using various photon (6-25 MV) and electron (3-12 MeV) energies. Measurements were performed using solid water and wax phantoms, and the results were evaluated with a microSTAR reader. The results showed that NanoDot OSLDs exhibited excellent linearity in the 0-500 cGy clinical dose range. It was determined that the dosimeters were not significantly affected by gantry angle, field size, or dose rate. These characteristics led to the conclusion that the dosimeter is a suitable measurement tool for modern and complex treatment techniques such as Intensity Modulated Radiation Therapy (IMRT). However, a distinct energy dependence was observed for both photon and electron beams, necessitating the use of energy-specific correction factors for accurate dose measurement. Furthermore, less than 6% signal fading was detected in the dosimeters at the end of a 240-day follow-up period, demonstrating the system's high stability. In conclusion, this study confirms the usability of the NanoDot OSLD system as a reliable in-vivo dosimetry tool in clinical radiotherapy applications.
Benzer Tezler
- Localized plasmon-coupled semiconductor nanocrystal emitters for innovative device applications
Yenilikçi aygıt uygulamaları için lokal plazmon katkılı yarı iletken nanokristal ışıyıcılar
İBRAHİM MURAT SOĞANCI
Yüksek Lisans
İngilizce
2007
Elektrik ve Elektronik Mühendisliğiİhsan Doğramacı Bilkent ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. HİLMİ VOLKAN DEMİR
- InN nano parçacıkların gerçek zamanlı büyütülme kinetiği
Real-time kinetics of InN nanodot growth
BURCU TOYDEMİR
Yüksek Lisans
Türkçe
2011
Fizik ve Fizik MühendisliğiGebze Yüksek Teknoloji EnstitüsüFizik Ana Bilim Dalı
YRD. DOÇ. DR. LEYLA ÇOLAKEROL ARSLAN
- Investigation of the structural properties of silicene nanoribbons by molecular dynamics simulations
Moleküler dinamik benzetimi ile silisen nanoşeritlerin yapısal özelliklerinin incelenmesi
ALPER İNCE
Yüksek Lisans
İngilizce
2012
Fizik ve Fizik MühendisliğiOrta Doğu Teknik ÜniversitesiMikro ve Nanoteknoloji Ana Bilim Dalı (disiplinlerarası)
PROF. DR. ŞAKİR ERKOÇ
PROF. DR. MEHMET KADRİ AYDINOL
- Production of BaMeO3 doped YBCO superconducting thin films by TFA-MOD technique
BaMeO3 katkılı YBCO süperiletken ince filmlerin TFA-MOD yöntemi ile üretilmesi
MURAT BEKTAŞ
Yüksek Lisans
İngilizce
2012
Metalurji MühendisliğiDokuz Eylül ÜniversitesiMetalurji ve Malzeme Mühendisliği Ana Bilim Dalı
PROF. DR. ERDAL ÇELİK
- Çok katlı Ge,SiGe nanokristal oluşumu ve nanokristalli metal oksit yarıiletken kapasitör uygulaması
Fabrication of multilayer Ge, SiGe nanocrystals and it? s application in dot mos capacitor
BEKTAŞ AKYAZI
Yüksek Lisans
Türkçe
2011
Fizik ve Fizik MühendisliğiKırıkkale ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. SEDAT AĞAN