Farklı post-core materyalleri ve siman renkleri kullanılarak, in-cream ve IPS empress tam seramik restorasyonlardaki renk değişikliğinin incelenmesi
Effects of different post-core materials and colors of cement on the final color of in-cream and IPS empress ceramic restorations
- Tez No: 99545
- Danışmanlar: DOÇ.DR. FİLİZ KEYF
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Post-core, tam seramik, siman, renk, post-core, all ceramic, cement, color
- Yıl: 2001
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Belirtilmemiş.
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET Altunsoy, S., Farklı post-core materyalleri ve siman renkleri kullanılarak, In-Ceram ve IPS Empress tam seramik restorasyonlardaki renk değişikliğinin incelenmesi, Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü Protez (Diş) Programı Doktora Tezi, Ankara, 2001. Bu çalışmada, seramik (IPS Empress cosmoingot), krom-nikel (Cr-Ni) ve opak kaplanmış krom-nikel (Cr-Ni+opak) post-core materyalleri ve opak beyaz, beyaz, sarı ve kahverengi siman (Variolink II) renkleri kullanılarak, bunların tam seramik restorasyonların (In-Ceram, IPS Empress ve IPS Empress 2) sonuç rengine etkileri incelenmiştir. Post-core materyallerinden 14±0,5 mm çapında ve 1,5±0,05 mm kalınlığında her gruptan 10 adet olmak üzere toplam 30 adet disk hazırlanmıştır. Ayrıca 14±0,5 mm çapında ve 0,1±0,01 mm kalınlığında her gruptan 10 adet olmak üzere toplam 40 adet siman disk hazırlanmıştır. Tam seramik materyallerinden de posf-core'larla aynı çapta ve kalınlıkta birer adet disk hazırlanmıştır. Çalışmanın 1. bölümünde sonuç renge, post-core materyallerinin etkisi incelenmiştir. Her grupta bir adet siman rengi ve bir adet tam seramik sabit tutulmuş, 10 tane farklı post-core materyali çalışılmıştır. Bir adet post-core, bir adet siman ve bir adet tam seramik disk üst üste konularak, toplam 36 grup oluşturulmuş ve kolorimetre ile toplam 396 ölçüm yapılmıştır. Çalışmanın 2. bölümünde sonuç renge siman renginin etkisi incelenmiştir. Her grupta bir adet post-core ve bir adet tam seramik materyali sabit tutulmuş, her renkten 10 tane farklı renk siman ile çalışılmıştır. Bir adet post-core, bir adet siman ve bir adet tam seramik disk üst üste konularak toplam 36 grup oluşturulmuş ve kolorimetre ile toplam 363 ölçüm yapılmıştır. Her iki bölümde de dentin, post-core materyalinin yerine konularak kontrol örnekleri oluşturulmuş ve kolorimetrede ölçülmüştür. In-Ceram sistemi için her üç post-core materyali de klinik olarak kabul edilir sınırlardadır (AE<2). IPS Empress sistemi için, seramik post-core tüm siman renkleriyle, Cr-Ni+opak post-core ve Cr-Ni post-core sadece opak beyaz siman kullanıldığında klinik olarak kullanılabilir bulunmuştur (AE<2). IPS Empress 2 sistemi için, seramik post-core ve Cr-Ni+opak post-core tüm siman renklerinde, Cr-Ni post-core ise sadece opak beyaz siman kullanıldığında klinik olarak kullanılabilir bulunmuştur (AE<2). Siman renkleri ele alındığında; In-Ceram sistemi için, her dört renkte klinik olarak kabul edilir sınırlardadır (AE<2). IPS Empress sistemi için, sadece seramik post-core materyali kullanıldığı zaman, beyaz, sarı ve kahverengi simanlar klinik olarak kabul edilebilir bulunmuştur (AE<1). IPS Empress 2 sistemi için, seramik post-core ve Cr-Ni+opak post-core kullanıldığında bütün renkler, Cr-Ni post- core kullanıldığında ise sadece opak beyaz siman klinik olarak kabul edilir sınırlarda bulunmuştur (AE<2).
Özet (Çeviri)
VI ABSTRACT Altunsoy, S., Effects of different post-core materials and colors of cement on the final color of In-Ceram and IPS Empress ceramic restorations, Hacettepe University Health Sciences Institue PhD Thesis in Prosthetic Dentistry, Ankara, 2001. In this study, the effects of ceramic (IPS Empress cosmo Ingot), chromium-nickel (Cr-Ni) and ceramic opaque sinterized on chromium-nickel (Cr-Ni+opaque) post-core materials and different colored (opaque white, white, yellow and brown) cements (Variolink II) on final color of all-ceramics materials (In-Ceram, IPS Empress and IPS Empress 2) were investigated. Three groups of post-cores (ceramic, Cr-Ni and Cr-Ni+opaque), 10 samples per each group, were prepared as discs 14+0,5 mm in diameter and 1,5+0,05 mm in thickness. Additionally, a total of 40 cement samples, 10 per each group (opaque white, white, yellow and brown) were prepared as discs 14±0,05 mm in diameter and 0,1 ±0,01 mm in thickness. One sample of four different dental ceramics (In-Ceram, IPS Empress and IPS Empress 2) was prepared as discs in similar dimensions. In the first part of the study, the effect of post-core materials was evaluated on the final color. In each group, while one cement color and one all ceramic material remained constant, 10 different post- core materials were studied. A total of 36 groups were established, in which each group contained a post-core, a resin cement and a ceramic disc. The color configurations were assessed with 396 measures with a colorimeter per each group. In second part of the study, the effect of cement color was evaluated on final color. In each group, while one post-core and one all ceramic materials remained constant, 10 different cement colors were studied. A total of 36 groups were established, in which each group contained a post-core, a resin cement and a ceramic disc. The color configurations were assessed with 363 measures with a colorimeter per each group. In both parts of the study dentin was placed instead of post-core materials as for control samples and measured with a colorimeter. In the evaluation of post-core materials; For the In-Ceram system, all three post-core materials were found to be within clinically acceptable limits (AE<2). For the IPS Empress system, the ceramic post-core was found to be clinically acceptable with all colors and both Cr-Ni+opaque and Cr-Ni post-cores were acceptable only with opaque white cement (AE<2). In IPS Empress 2 system, ceramic and Cr-Ni+opaque post-core were found to be clinically suitable for all cement colors, whereas Cr-Ni post-core was suitable for only opaque white cement (AE<2). In the evaluation of cement colors; For In-Ceram system, all four colors were within clinically acceptable limits (AE<2). In IPS Empress system, when only ceramic post-core material was used, white, yellow and brown cements were found to be clinically acceptable (AE<1). For IPS Empress 2 system, all colors for ceramic and Cr-Ni+opaque post-core were clinically acceptable but only opaque white cement for Cr-Ni post-core were found to be acceptable clinically (AE<2).
Benzer Tezler
- Farklı ferrule seviyelerinde amalgam ve kompozit rezin core uygulanmış endodontik tedavili dişlerin sıkışma-kesme kuvvetine karşı direncinin incelenmesi
The Determination of the resistance of amalgam and composite core applied endodontic treatment in different ferrule effects against compressive-shear forces
MUSTAFA KALKAN
Doktora
Türkçe
1998
Diş HekimliğiSelçuk ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. BÜLENT KESİM
- Farklı endodontik post sistemlerinin dirençlerinin in vitro olarak incelenmesi
In vitro evaluation of fracture strengths for different endodontic post
FARUK TANER DİLMENER
Doktora
Türkçe
2000
Diş HekimliğiMarmara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. TURAN BİŞKİN
PROF. DR. HALUK KESKİN
- Endodontik tedavili dişlerde uygulanan fabrikasyon ve döküm post tasarımlarında çiğneme kuvvetlerinin oluşturduğu gerilimlerin sonlu elemanlar stres analizi yöntemiyle incelenmesi
Finite element stres analysis of effect of prefabricated and cast post and core systems on stress distribution generated by chewing forces in endodontically treated teeth
AYŞE DİDEM MUMCU
Doktora
Türkçe
1998
Diş HekimliğiGazi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. YAVUZ BURGAZ
- Üç farklı post-core sisteminin in vitro şartlarda sıkışma-kesme kuvvetlerine dayanımlarının incelenmesi
Investigation of shear-compressive strenghts of there different post-core systems in in-vitro conditions
HAKAN AKAN
Doktora
Türkçe
2000
Diş HekimliğiSelçuk ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. BÜLENT KESİM
- Oblik kuvvet karşısında iki farklı post-kor sisteminin gösterdiği direncin ve kök kırığının incelenmesi
Başlık çevirisi yok
MURAT ESKİTAŞÇIOĞLU