Peri-implant mukozitis ve peri-implantitis tedavisinde kullanılan Er,Cr: YSGG ve diyot lazerlerin titanyum yüzeyler üzerine etkilerinin in vitro olarak değerlendirilmesi

In vitro evaluation of the effects of Er, Cr: YSGG, and diode lasers used in the treatment of peri-implant mucositis and peri-implantitis on titanium surfaces

  1. Tez No: 988875
  2. Yazar: MEHMET BÜYÜKTARAKCI
  3. Danışmanlar: PROF. DR. MÜKERREM HATİPOĞLU
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Akdeniz Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Periodontoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Peri-implant hastalık tedavisinde, Erbiyum, krom katkılı: itriyum, skandiyum, galyum, garnet (Er,Cr:YSGG) ve diyot lazer kullanımının titanyum(Ti) implant yüzeyi sıcaklık değişimi ve yüzey pürüzlülüğü üzerindeki etkisinin değerlendirilmesidir. Yöntem: Çalışmamızda silindir şeklinde üretilen, bir düz yüzeyinde lazer uygulaması yapılan ve diğer yüzeyinde termokupl yerleştirmek için yuva tasarlanmış Ti implant modelleri kullanılmıştır. Ti silindirleri sabitlemek için üç boyutlu yazıcıdan parmak desteği olan stant üretilmiştir. Standa sabitlenen Ti silindirlerin yuva kısmına termokupl sabitlenerek Er,Cr:YSGG (2780nm) lazer ve (20 ve 40 saniye; 1.5W, 2.5W ve 3.5W), diyot lazer (940nm) ile (20 ve 40 saniye; 0.8W, 1.3W ve 1.8W) kontak olarak uygulama yapılmıştır. Uygulama esnasında başlangıç ve bitiş sıcaklık değerleri kayıt altına alınmış, sıcaklık değişimleri hesaplanmıştır. Uygulama sonrası modeller, taramalı elektron mikroskobu(SEM) ve atomik güç mikroskobu(AFM) ile iki ve üç boyutlu olarak incelenmiştir. Bulgular: Titanyum silindirlerin ışınlama sırasındaki sıcaklık değişimleri değerlendirildiğinde, 40 saniye boyunca diyot lazerle uygulama yapılan silindirler, 20 saniye boyunca lazer uygulananlardan daha yüksek bulunmuştur. Er,Cr:YSGG ile muamele edilen silindirlerde sıcaklık bazı örneklerde azalırken, bazı örneklerde minimum düzeyde arttı. Profilometre değerleri (Ra) tüm gruplar için pürüzlülük açısından istatistiksel olarak anlamlı değildi. Bununla birlikte, SEM görüntüleri işlem görmüş yüzeylerde erime ve mikro gözenek sayısında artış olduğunu gözlenmiştir. Sonuç: Her iki lazer uygulamasında yüzey pürüzlülük değişiminde anlamlı bir fark bulunmadı. Diyot lazerin ek bir soğutma sistemi olmadan yüksek Watt'ta kullanımının eşik sıcaklık değerine yaklaştığı, Er,Cr:YSGG lazerin kullanımın ise sıcaklık değişimi açısından güvenli aralıkta kaldığı görüldü.

Özet (Çeviri)

Objective: To evaluate the effect of Er,Cr:YSGG and diode laser on titanium (Ti) implant surface temperature change and surface roughness in the treatment of peri-implant disease. Methods: In our study, Ti implant models produced in the form of cylinders, with laser application on one flat surface and a slot for thermocouple placement on the other surface were used. To fix the Ti cylinders, a stand with finger support was produced from a 3D printer. The thermocouple was fixed to the hollow part of the Ti cylinders fixed on the stand and the Er,Cr:YSGG (2780nm) laser and (20 and 40 seconds; 1.5W, 2.5W and 3.5W), Diode laser (940nm) (20 and 40 seconds; 0.8W, 1.3W and 1.8W) were applied as contact. During the application, initial and final temperature values were recorded, and temperature changes were calculated. After the application, the models were examined in two and three dimensions by scanning electron microscopy (SEM) and atomic force microscopy (AFM). Results: When the temperature changes of titanium cylinders during irradiation were evaluated, cylinders irradiated with a diode laser for 40 seconds were significantly higher than those irradiated for 20 seconds. In the Er,Cr:YSGG-treated cylinders, the temperature decreased in some samples and increased minimally in others. Profilometer values (Ra) were not statistically significant in terms of roughness for all groups. However, SEM images showed melting and an increase in the number of micropores on the treated surfaces. Conclusion: There was no significant difference in surface roughness in both laser applications. The use of a diode laser at high wattage without an additional cooling system approaches the threshold temperature, while the use of the Er,Cr:YSGG laser remained within the safe range in terms of temperature change.

Benzer Tezler

  1. Çukurova bölgesinde biyoklimatik veriler kullanılarak açık ve yeşil alan sistemlerinin belirlenmesi ilkeleri üzerinde bir araştırma

    A research on the determination of the principles in open and green spaces systems by using the bioclimatic data in Çukurova region

    MEHMET FARUK ALTUNKASA

    Doktora

    Türkçe

    Türkçe

    1987

    Çevre MühendisliğiÇukurova Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    DOÇ. DR. ERDOĞAN GÜLTEKİN

  2. Malignite ile tek gen mutasyonları ve kromozom düzensizliklerinin ilişkisi üzerine araştırmalar

    Investigations on the relationship between malignancy and a single gene mutation and chromosomal abnormalities

    M. NAİL ALP

    Doktora

    Türkçe

    Türkçe

    1983

    Tıbbi BiyolojiDicle Üniversitesi

    Tıbbi Biyoloji Ana Bilim Dalı

    DOÇ.DR. NURETTİN BAŞARAN