Bir ticari bina iklimlendirme sistemine entegre edilmiş buz depolama sisteminin enerji verimliliği için optimum şartların araştırılması

Investigation of optimum conditions for energy efficiency of ice storage system integrated with air conditioning system for a commercial building

  1. Tez No: 987407
  2. Yazar: ENES HÜSEYİN ERGÜN
  3. Danışmanlar: PROF. DR. SALİH COŞKUN
  4. Tez Türü: Doktora
  5. Konular: Makine Mühendisliği, Enerji, Mechanical Engineering, Energy
  6. Anahtar Kelimeler: Hibrit soğutma, Isı enerjisi, Soğutma enerjisi, Termal enerji, Ticari enerji, Hybrid cooling, Heat energy, Cooling energy, Thermal energy, Commercial energy
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Bursa Uludağ Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışma, ticari binaların iklimlendirme sistemlerinin yaz aylarındaki pik saatlerde yol açtığı yüksek enerji tüketimi ve işletme maliyetleri sorununu, Buz Depolama Sisteminin (BDS) enerji verimliliği ve optimum çalışma şartları bağlamında araştırmaktadır. Metodoloji, özgün olarak tasarlanmış deney düzeneği üzerinde gerçekleştirilen deneysel analizler ile bir TRNSYS simülasyon modelinin oluşturulması ve optimizasyon çalışmalarını içermektedir. Deneysel aşamada, sistem 8 saatlik gece şarjı stratejisiyle test edilmiştir. Termal analizler, BDS'nin 7,70 kWh termal enerji depoladığını ve düşük ortam sıcaklığından faydalanarak 1,42(±0,06) gibi yüksek bir şarj Performans Katsayısı (COP) ile çalıştığını göstermiştir. Deşarj verimliliği %67,5(±%2,4) olarak tespit edilmiş ve enerji kayıplarının büyük çoğunluğunun yetersiz tank yalıtımından kaynaklandığı hesaplanmıştır. Ekonomik açıdan, BDS stratejisinin, aynı soğutma işini pahalı gündüz tarifesiyle yapmaya kıyasla %20 işletme maliyeti avantajı sağladığı hesaplanmıştır. TRNSYS modelinin soğutma analizleri, BDS'nin kontrol stratejilerinin maliyet üzerindeki kritik etkisini göstermiştir. Tam Depolama, yükü geceye kaydırarak en düşük maliyete (1.118,70 TL) ulaşmış ve tasarruf sağlamıştır. Buna karşın, Hibrit/Kısmi Depolama, yetersiz kapasite nedeniyle gündüz soğutmaya geçiş yapmış, 7.000 kJ/h pik güç çekerek en yüksek maliyetli senaryo (1.994,02 TL) olarak tespit edilmiştir. TRNSYS ile Tam Depolama sistemi üzerinde yapılan optimizasyon çalışmaları, BDS'nin ekonomik potansiyelini maksimize eden nicel şartları belirlemiştir. En düşük işletme maliyetini sağlayan optimum tank hacmi 4,98 m3 olarak belirlenmiştir. İşletme koşulları için ise 100 kg/h pompa debisi en uygun işletme şartı olarak tespit edilmiştir. Sonuç olarak, BDS'nin ekonomik avantajının sürdürülebilmesi için Tam Depolama stratejisi ve belirlenen nicel boyutlandırma şartlarına uyulması, Hibrit sistemler için ise maliyet piklerini önlemek amacıyla Talep Sınırlama kontrol mekanizmalarının entegre edilmesi gerekmektedir.

Özet (Çeviri)

This study investigates high energy consumption and operating costs caused by commercial building HVAC systems during peak summer hours, focusing on the energy efficiency and operating conditions of Ice Thermal Energy Storage (ITES) systems. The methodology includes experimental analyses on a custom design and TRNSYS simulation modeling with optimization. Experimentally, the system was tested with an 8-hour night charging strategy. Thermal analyses showed the ITES stored 7.70 kWh with a high charging Coefficient of Performance (COP) of 1.42(±0.06), utilizing low ambient temperatures. Discharge efficiency was 67.5%(±2.4%), with major losses attributed to insufficient tank insulation. Economically, the ITES strategy provided a 20% operational cost advantage compared to expensive daytime tariffs. TRNSYS cooling analyses demonstrated the critical impact of control strategies on cost.“Full Storage”achieved the lowest cost (1,118.70 TL) by shifting the load to nighttime. Conversely,“Hybrid/Partial Storage”was the highest cost scenario (1,994.02 TL) due to insufficient capacity leading to daytime peak power draws (7,000 kJ/h). TRNSYS optimization on the Full Storage system determined quantitative conditions maximizing economic potential. The optimum tank volume for lowest operating cost was 4.98 m³, with an optimum pump flow rate of 100 kg/h. Consequently, sustaining economic advantages requires adhering to the Full Storage strategy and determined sizing conditions, while Hybrid systems need Demand Limiting controls to avoid cost peaks.

Benzer Tezler

  1. Theoretical modeling of the energy efficiency of a shopping mall

    Bir alışveriş merkezinin enerji verimliliğinin teorik modellenmesi

    HAMZA ABUALESS

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    EnerjiAtatürk Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. KADİR BİLEN

  2. Binalarda termal enerji depolama ile yapılan enerji tasarrufu

    The energy savings in buildings with a thermal energy storage

    TÜRKAY YEŞİLKAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Makine MühendisliğiYıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. DERYA BURCU TÜMER ÖZKAN

  3. Bina otomasyon sistemleri

    Building automotion systems

    MUSTAFA MURAT GENLİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    Elektrik ve Elektronik MühendisliğiYıldız Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. OSMAN KILIÇ

  4. Yaklaşık sıfır enerji konseptli binalar için gerçek zamanlı enerji optimizasyonu fizibilitesi

    Real-time energy optimization feasibility for nearly zero energy buildings (NZEB) concept

    HACER GEDİZ TAŞKIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    EnerjiAkdeniz Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HAMZA FEZA CARLAK

  5. Toplam inşaat alanı yirmibin metrekareden büyük ticari yapılarda kojenerasyon sisteminin alternatif sistemlerle enerji ve bina maliyeti açısından karşılaştırılması

    Energy consumption and cost analysis comparison of cogeneration system with alternative systems for commercial buildings which have construction area more than twentythousand metersquare

    ALPERDENİZ AYDOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    Makine MühendisliğiGazi Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. MECİT SİVRİOĞLU