Farklı açılanmalara sahip titanyum tabanlı dayanak destekli köprü restorasyonların uzun dönem kullanım sonrası tork kayıplarının incelenmesi

Investigation of torque losses in titanium-base abutment–supported fixed dental prostheses with different angulations after long-term simulated use

  1. Tez No: 985511
  2. Yazar: MEHMET SALİH SAMUK
  3. Danışmanlar: PROF. DR. ÇAĞRI URAL
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı, farklı açılarda yerleştirilmiş titanyum tabanlı dayanak destekli implant üstü köprü restorasyonlarında, uzun dönem kullanımı taklit edecek şekilde uygulanan dinamik yükleme sonrası tork kayıp değerlerini in-vitro olarak değerlendirmek ve karşılaştırmaktır. Materyal ve Metot: Çalışmada iki ayrı hasta senaryosuna uygun şekilde (n=10) toplam 24 örnek hazırlandı. Çapı 4.1 mm, boyu 10 mm olan implantlar epoksi rezine yerleştirildi ve 3 mm'lik kemik rezorpsiyonu simüle edilecek biçimde konumlandırıldı. Örneklerin yarısı paralel (0°), yarısı 15° açılı olacak şekilde planlandı. Her implant için titanyum tabanlı dayanak üzerine dijital iş akışı ile üretilmiş üç üyeli, vida tutuculu monolitik zirkonyum restorasyonlar hazırlandı. Tüm vidalar 30 N·cm ile sıkıldı ve başlangıç gevşeme torku (GTD1) kaydedildi. Çiğneme simülatöründe yaklaşık 50 N, 1.6 Hz ve 240.000 döngü uygulandı; ardından GTD2 ölçüldü. Daha sonra vidalar yeniden torklandı ve GTD3 kaydedildi. Kesit analizi amacıyla 4 test örneği ayrılmış; bunların 2'si dinamik yükleme öncesinde, 2'si ise dinamik yükleme sonrasında seçilmiştir. Bulgular: Dinamik yükleme sonrası tüm gruplarda gevşeme torku değerlerinde anlamlı azalma gözlenmiştir (p<0.05). Açılı (15°) ve paralel (0°) restorasyonlar arasında tork kaybı açısından anlamlı fark bulunmamıştır (p>0.05). Yeniden torklama sonrasında (GTD3) gruplar arasında fark görülmemiştir (p>0.05). Test süresince hiçbir örnekte vida/restorasyon kırığı, tam vida gevşemesi veya köprü desimantasyonu görülmemiştir. Sonuç: Dinamik yükleme sonrasında örneklerin tamamının tork değerlerinde anlamlı bir düşüş meydana gelmiştir. Açılı ve paralel yerleşimli restorasyonlar arasında tork kaybı açısından istatistiksel olarak anlamlı bir fark bulunmamışken , esas farklılaşma implantın bölgesel konumuna (premolar–molar) göre gerçekleşmiştir. Yeniden torklama işlemi, ön yük kaybını telafi ederek gruplar arası mevcut farklılıkları büyük ölçüde ortadan kaldırmıştır.

Özet (Çeviri)

Aim: The purpose of this study is to evaluate and compare, in vitro, the torque loss values after dynamic loading simulating long-term use in titanium-base abutment–supported implant fixed dental prostheses placed at different angulations. Materials and Methods: Twenty-four specimens were prepared based on two clinical scenarios (n = 10 ). Implants (4.1 mm × 10 mm) were embedded in epoxy resin blocks and positioned to simulate 3 mm of crestal bone loss. Twelve specimens were aligned parallel (0°) and twelve at a 15° angulation. For each implant, a three-unit, screw-retained monolithic zirconia restoration was fabricated via a digital workflow on a titanium-base abutment and luted with resin-based cement. Abutment screws were tightened to 30 N·cm, and the baseline reverse torque (GTD1) was recorded. The specimens were then subjected to 240,000 cycles in a chewing simulator (50 N, 1.6 Hz), after which GTD2 was measured. Subsequently, all screws were retightened to 30 N·cm and GTD3 was recorded. A total of 4 test specimens were allocated for sectioning, with 2 before dynamic loading and 2 after dynamic loading Results: After dynamic loading, a significant reduction in reverse torque values was observed in all groups (p<0.05). No significant difference in torque loss was found between angled (15°) and parallel (0°) restorations (p>0.05). Following retightening (GTD3), no difference was detected among the groups (p>0.05). Throughout the test period, no screw/restoration fracture, complete screw loosening, or prosthesis debonding was observed Conclusion: Dynamic loading led to a significant reduction in torque in all specimens. No statistically significant difference in torque loss was found between angled and parallel implant placements, whereas the primary differentiation was associated with regional location (premolar vs molar). Retightening compensated for preload loss and largely neutralized existing intergroup differences.

Benzer Tezler

  1. Assessment of hard tıssue densıty around dental ımplants usıng conventıonal radıographs

    Dental implantlar çevresindeki sert doku densitesinin konvensiyonel radyograflar ile incelenmesi

    WAEL ALSHAIBANI

    Doktora

    İngilizce

    İngilizce

    2010

    Diş HekimliğiGazi Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. NUR MOLLAOĞLU

  2. Farklı tipteki kapaklı lingual ortodonti braketleri ile nikel titanyum ve paslanmaz çelik teller arasındaki sürtünme dirençlerinin in vitro olarak değerlendirilmesi

    In vitro evaluation of frictional resistance between different self ligating lingual brackets and nickel titanium and stainless steel archwires

    GÜLŞİLAY SAYAR

    Doktora

    Türkçe

    Türkçe

    2010

    Diş Hekimliğiİstanbul Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. YILDIZ ÖZTÜRK ORTAN

  3. Beş farklı ortodontik braket tipinin paslanmaz çelik ve beta titanyum ark teli materyalleriyle ortaya çıkardıkları sürtünme kuvvetlerinin incelenmesi

    Evaluation of frictional forces released by five different bracket materials when used in combination with stainles steel and beta titanium archwires

    BERNA YÜZBAŞ

    Doktora

    Türkçe

    Türkçe

    2007

    Diş HekimliğiYeditepe Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF.DR. TÜLİN ARUN

  4. Farklı ligasyon sistemlerinin oluşturduğu sürtünme kuvvetlerinin karşılaştırılmalı olarak incelenmesi

    In vitro comparison of static frictional forces of 6 different ligation types in dry and wet state

    AHU ÇİĞDEM TABAKOĞLU

    Doktora

    Türkçe

    Türkçe

    2007

    Diş HekimliğiYeditepe Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF.DR. TÜLİN ARUN

  5. Farklı estetik braketler ile farklı ark teli kombinasyonları arasında oluşan sürtünme dirençlerinin in vitro olarak değerlendirilmesi

    A comparative in vitro study of frictional resistances between different esthetic brackets and different orthodontic archwires

    AYŞENUR BATU GÜNEY

    Doktora

    Türkçe

    Türkçe

    2017

    Diş Hekimliğiİstanbul Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. GÜLNAZ MARŞAN