Geri Dön

Yoğuşmayan korozif gazların jeotermal buhardan alınması için tasarlanan yoğuşturma/kaynatma modelli ısı değiştirgeçleri (reboilerler) üzerine teorik ve deneysel incelemeler

Theoretical and experimental investigations on condensation/boiling modelled heat exchangers (reboilers) designed for removal of noncondensable gases from geothermal steam

  1. Tez No: 96455
  2. Yazar: GÜLDEN GÜNERHAN (GÖKÇEN)
  3. Danışmanlar: DOÇ. DR. MUHAMMED ELTEZ
  4. Tez Türü: Doktora
  5. Konular: Enerji, Energy
  6. Anahtar Kelimeler: Jeotermal enerji, yoğuşmayan gazlar, reboiler, Kızıldere, Türkiye, Güneş enerjisi, Isı değiştiriciler, Geothermal power plant, noncondensable gas, upstream reboilers, Kızıldere, Turkey, Solar energy, Heat exchangers, Geothermal energy, Noncondensible gases
  7. Yıl: 2000
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Güneş Enerjisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET YOĞUŞMAYAN KOROZİF GAZLARIN JEOTERMAL BUHARDAN ALINMASI İÇİN TASARLANAN YOĞUŞTURMA/KAYNATMA MODELLİ ISI DEĞİŞTİRGEÇLERİ (REBOİLERLER) ÜZERİNE TEORİK VE DENEYSEL İNCELEMELER GÖKÇEN GÜNERHAN, Gülden Doktora Tezi, Güneş Enerjisi Anabilim Dalı Tez Danışmanı : Doç.Dr. Muhammed ELTEZ Şubat 2000, 260 sayfa Bu çalışmanın amacı, Kızıldere jeotermal sahası özelinde yüksek yoğuşmayan gaz oranma (CO2, H2S, NH3, N2, CH4, vb.) sahip jeotermal sahalarda gaz kompresörlerinden kaynaklanan parazitik yükleri azaltma ve güç üretimini arttırma olanaklarını araştırmaktır. Kızıldere jeotermal sahasında yoğuşmayan gaz oranı, ağırlıkça buharın % 10-20 'si arasında kuyudan kuyuya değişiklik gösterir. Bu miktardaki yoğuşmayan gazı kondenserden almak için kullanılan gaz kompresörleri santralde üretilen brüt enerjinin %18.3'ünü kullanırlar. Çalışmada, Kızıldere jeotermal santralı gaz alma sistemine alternatif olarak türbin öncesi reboiler sistemleri incelenmiştir. İlk aşamada bir düşey borulu tip reboiler dizayn edilmiş ve teorik çalışma sonunda, yoğuşmayan gaz oranı arttıkça gövde tarafı ısı transfer katsayısının hızla azaldığı görülmüştür. Bu nedenle, literatürde de belirtildiği gibi yoğuşmayan gaz oranı % 12- 15 'in üzerindeki sahalar için direkt temaslı reboiler sistemlerinin Kızıldere sahası için incelenmesi önerilmiştir. İkinci aşama olarak 380 W'lik bir direkt temaslı tip reboiler dizayn ve imal edilerek 3 ay süreyle Kızıldere jeotermal sahasında test edilmiştir. Temel testlerde %72.2-98.8 yoğuşmayan gaz ayırma verimi elde edilmiştir.

Özet (Çeviri)

VI ABSTRACT THEORETICAL AND EXPERIMENTAL INVESTIGATIONS ON CONDENSATION/BOILING MODELLED HEAT EXCHANGERS (REBOILERS) DESIGNED FOR REMOVAL OF NONCONDENSABLE GASES FROM GEOTHERMAL STEAM GOKCEN GUNERHAN, Gulden Ph.D. in Solar Energy Supervisor: Assoc. Prof. Dr. Muhammed ELTEZ February 2000, 260 pages The aim of this study is to investigate the posibilities increasing power generation capacity and reducing the parasitic load by gas compressors of geothermal power plants which use geothermal steam containing high level of noncondensable gases (NCG's) (such as C02, H2S, NH3, N2, CH4, He and H2) like Kızıldere geothermal power plant. Kızıldere geothermal field contains NCG's as high as 10-20% by weight of steam. This amount of NCG's are being extracted from the condenser by gas compressors that consume about 18.3% of the total power production of the plant In this work, upstream reboiler systems are investigated as an alternative to conventional gas extraction systems for Kızıldere geothermal power plant. A vertical tube type reboiler has been designed and it is found that, as NCG content increases, the condensation heat transfer coefficient reduces steeply. The investigation of direct contact reboilers for fields that contain high levels of NCG (>12-15% by weight of steam) is recommended. The next step was to design a direct contact reboiler and test in the Kızıldere geothermal field. A bench scale unit which has a capacity of 380 W is constructed and tested for 3 months. The tests are carried out with a gas removal efficiency of 72.2-98.8% for various reboiler pressures.

Benzer Tezler

  1. Düşey borularda su buharının yoğunlaşmasına yoğuşmayan gazların tesiri

    The Effect of the non-condensable gases on the condensation of steam in the vertical pipes

    İSAK KOTCİOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Makine MühendisliğiGazi Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    DOÇ.DR. A. YÜCEL UYAREL

  2. Yatay borularda su buharı ve su buharı-yoğuşmayan gaz (hava) karışımının film yoluyla yoğuşmasının incelenmesi

    Başlık çevirisi yok

    NECDET ALTINTOP

    Doktora

    Türkçe

    Türkçe

    1989

    Makine MühendisliğiSelçuk Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. AKBAY TUĞAN GÖKÇE

  3. Helezon borulu metal yoğuşma yüzeyli sera tipi damıtıcı

    Başlık çevirisi yok

    KURTULUŞ BORAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Makine MühendisliğiGazi Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    Y.DOÇ.DR. ALİ YÜCEL UYAREL

  4. Buhar tesisatlarındaki enerji tasarrufu çalışmalarında kondenstopların rolü

    The Effect of steam traps in the energy saving applications about the steam systems

    EMRE ÇETİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    Makine MühendisliğiYıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. OLCAY KINCAY