Geri Dön

Erzincan kenti evsel atıksularının karakterizasyonu ve atıksu arıtma tesisinin GPS-X Bilgisayar programı kullanılarak modellenmesi

Domestic Wastewater characterization of Erzincan city and modelling of Wastewater treatment plant by using GPS-X computer software

  1. Tez No: 96372
  2. Yazar: ALPER NUHOĞLU
  3. Danışmanlar: PROF. DR. BÜLENT KESKİNLER, PROF. DR. MEHMET KARPUZCU
  4. Tez Türü: Doktora
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Aktif çamur, Atık su, Atık su arıtma, Bilgisayar programları, Denitrifikasyon, Erzincan, Evsel atık su, Matematiksel modelleme, Nitrifikasyon, Activated sludge, Waste water, Waste water treatment, Computer programs, Denitrification, Erzincan, Domestic sewage, Mathematical modelling, Nitrification
  7. Yıl: 2000
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Erzincan Kenti Atıksu Arıtma Tesisin' de yürütülen bu çalışma dört ana kademede gerçekleştirilmiştir. İlk olarak tesisin mevcut işletme stratejisi ve arıtma performansı değerlendirilmiş ve iyi işletilmediği sonucuna varılmıştır. İkinci kademede Erzincan kenti evsel atıksuları karbonlu ve azotlu maddelere göre karakterize edilmiş ve giriş suyunda ölçülen parametrelerin ortalama değerleri şu şekilde bulunmuştur ; TKOİ : 430 mg/L, ÇKOİ : 233mg/L, Sı : 45.8 mg/L, Ss :86.7 mg/L, Xs : 161.7mg/L, N03-N :0.36 mg/L, NH4-N : 32 mg/L, çözünmüş organik N :11 mg/L, toplam N :43 mg/L ve AKM :199 mg/L. İncelenen periyotta çeşitli parametrelere göre tesisin arıtım performansı şu şekildedir ; TKOİ giderme verimi %80-87, ÇKOİ giderme oram %73-89, TN giderim oranının %6.6-36.8 ve NH4-N giderme veriminin %87.3-95.4 arasında olduğu belirlenmiştir. Çalışmanın üçüncü kısmında GPS-X bilgisayar programı kullanılarak mevcut tesis matematiksel olarak modellenmiş ve ölçülen değerlerle modelin hesapladığı değerler arasında iyi bir uyum olduğu tespit edilmiştir. Modelde biyokinetik reaksiyonlar için IAWQ Çalışma Grubu İNo'lu modeli, çöktürme havuzu için katmanlı çöktürücü modeli kullanılmıştır. Çalışmanın son aşaması olan çeşitli senaryoların model ile denenmesi durumunda çıkış suyu kalitesinin nasıl etkilendiği tespit edilmiş ve tesiste uygun işletme şartlarında çıkış suyu TN konsantrasyonun 15 mg/L seviyelerine ineceği hesaplanmıştır. Ayrıca taşlan durumu ve ani organik yüklemeler durumunda tesiste otomatik kontrol sistemlerinin kullanılmasıyla (P.I.D) tesis performansının arttırılabileceği görülmüştür.

Özet (Çeviri)

SUMMARY There are four major steps in this study in which it was performed at the Erzincan City Wastewater Treatment Plant. Firstly, current operational strategies and treatment performance were evaluated for the plant and it was concluded that the plant was poorly operated. At the second stage, domestic wastewater of Erzincan City were characterized for carbonaceous and nitrogenous substances,and the average values of parameters measured in influent were found as follows; TCOD :430 mg/L, SCOD : 233, Si :45.8 mg/L, Ss 86.7 mg/L and Xs : 161.7 mg/L., N03-N :0.36 mg/L, NH4-N : 32 mg/L, dissolved organic N :11 mg/L, Total N :43 mg/L and SS :199 mg/L. During the field study period, removal rates for TCOD was varied between 80-87 %, SCOD removal rates varied between 73-89%, TN removal rates varied between 6.6-36.8% and NH4-N removal rates varied between 87.3-95.4%. As a third stage of the study, treatment plant was modelled mathematically by using GPS-X computer software and for various parameters it was observed that there was a good agreement between measured and computed values. In mathematical modelling, IAWQ Task Group Model Nol was used for biochemical reactions and layered settler model was chosen for final settling tank At the last stage, the simulation of various scenarios on model, the way which the effluent quality would be effected was evaluated and it was calculated that the effluent TN concentration would be decreased to 15 mg/L under suitable operating conditions. And for the scenarios such as stormwater experience and sudden organic loads, it was calculated that the treatment plant performance would be increased by using automatic controllers (P.I.D. controllers).

Benzer Tezler

  1. Çapraz akışlı membran biyoreaktördedenitrifikasyon prosesi

    Başlık çevirisi yok

    ALPER NUHOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Çevre MühendisliğiAtatürk Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BÜLENT KESKİNLER

  2. Planlama sorunları açısından Erzincan`ın şehir coğrafyası

    Die plannungsproblem hinsichtlich die stadtgeographie von Erzincan

    M. SAMET ALTINBİLEK

    Doktora

    Türkçe

    Türkçe

    1997

    CoğrafyaAtatürk Üniversitesi

    Coğrafya Ana Bilim Dalı

    PROF. DR. HAYATİ DOĞANAY

  3. Erzincan il sınırları içindeki kına ezgilerinin incelenmesi

    Başlık çevirisi yok

    GÜLTEKİN EKE

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Halk Bilimi (Folklor)İstanbul Teknik Üniversitesi

    DOÇ. ŞENEL ÖNALDI

  4. Alpköy (Kemah-Erzincan) yöresinin jeolojik ve tektonik özellikleri

    Başlık çevirisi yok

    SÜHA ÖZDEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1992

    Jeoloji MühendisliğiCumhuriyet Üniversitesi

    Jeoloji Ana Bilim Dalı

  5. Erzurum`da ehram

    Başlık çevirisi yok

    ADEM ÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    El SanatlarıAtatürk Üniversitesi

    Geleneksel Türk El Sanatları Ana Bilim Dalı

    YRD. DOÇ. DR. ÖMÜR KOÇ