Geri Dön

Yüksek gerilim izolatörlerinde kirlenme atlamasının dinamik ark modeli

Dynamic arc modeling of pollution flashover of high voltage insulators

  1. Tez No: 96361
  2. Yazar: ZAFER AYDOĞMUŞ
  3. Danışmanlar: DOÇ.DR. MEHMET CEBECİ
  4. Tez Türü: Doktora
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: İzolatör, Sonlu Elemanlar Yöntemi, Kirlenme Atlaması, Atlama Denklemi, Dinamik Model, Dinamik modeller, Kirlilik, Yalıtım malzemeleri, Yüksek gerilim, Insulator, Finite Element Method, Pollution Flashover, Flashover Equation, Dynamic Model, Dynamic models, Pollution, Insulating materials, High voltage
  7. Yıl: 2000
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

II ÖZET DOKTORA TEZİ YÜKSEK GERİLİM İZOLATÖRLERİNDE KİRLENME ATLAMASININ DİNAMİK ARK MODELİ Zafer AYDOĞMUŞ Fırat Üniversitesi Fen Bilimleri Enstitüsü Elektrik-Elektronik Mühendisliği Anabilim Dalı 2000, Sayfa:92 Tüm dünyada elektrik enerjisine olan talebin artması, büyük miktarlarda elektrik gücünün uzak mesafelere iletilmesini zorunlu kılmıştır. Bunun sonucu olarak üretim ve iletimde yeni problemler ortaya çıkmıştır. İletim problemlerinin en önemlisi elektriksel izolasyonun sağlanmasıdır. Yüksek Gerilimde izolasyon amacıyla kullanılan izolatörlerin performansı, özellikle atmosferik kirlenmeler nedeniyle azalmakta ve iletim hatlarında işletme esnasında çeşitli arızalar meydana gelmektedir. Bu olumsuzluğu gidermek amacıyla, araştırmacılar tarafından çeşitli teknikler geliştirilmiş; ancak probleme kesin bir çözüm henüz bulunamamıştır. Bu çalışmada, Yüksek Gerilim İzolatörlerinde işletme süresince yüzeysel kirlenmelerden meydana gelen atlama olayı için yeni bir model geliştirilmiş; böylece problemin çözümüne" ve izolatörler üzerinde yapılan performansı iyileştirme çalışmalarına katkı sağlanması amaçlanmıştır. Bunun için önce atlama olayının fiziği ve bu konuda yapılan çalışmalar incelenmiştir. Sonra Sonlu Elemanlar Yöntemi kullanılarak, yüzeyi kir ile kaplı birIll izolatörde potansiyel ve alan dağılımları hesaplanmıştır. Hesaplanan bu değerlere göre, izolatör yüzeyi üzerinde kısmi deşarja neden olabilecek noktalar belirlenerek atlama kriterleri ile kontrol edilmiştir. Kısmi deşarj lann zamana bağlı olarak yayılması, kirli izolatör yüzeyinden kaçak akımın artması ve olayın yüzeysel atlama ile sonuçlanmasına neden olmaktadır. Bütün bu durumları göz önüne alan bir bilgisayar programı geliştirilmiştir. Program, problemi zaman ve iletkenlik değişimlerine bağlı olarak inceleyebilir. Program üzerinde yapılan çalışmalarla, izolatörlerin yüzeyi üzerindeki alan şiddeti değişimleri, arka seri kir direnci değişimleri ve atlama gerilimleri hesaplanarak grafikleri çizdirilmiş ve başka araştırmacıların sonuçlarıyla karşılaştınlmıştır.

Özet (Çeviri)

IV SUMMARY PhD Thesis DYNAMIC ARC MODELING OF POLLUTION FLASHOVER OF HIGH VOLTAGE INSULATORS Zafer AYDO?MUŞ Fırat University Graduate School of Natural and Applied Sciences Department of Electrical and Electronics Engineering 2000, Page:92 Increasing in demand of electrical energy in the world, transmission of large amount of electrical power to long distance has been necessary. As a result of this, new problems appear on both production and transmission. Most important problem on transmission is to satisfy electrical insulation. The performance of insulators used for insulation in high voltage decreases by atmospheric pollutions and some faults occur on the power line during operation. To remove this problem, some techniques has been developed by investigators, but a satisfactory solution has not been found yet. In this work, a new model has been developed to represent flashover phenomenon which occurs by means of surface pollution during operation conditions on high voltage insulators. By aiming, to solve this problem and to help contribute to the efforts for improving the performance. With this aim first, the physics of flashover phenomenon and studies on this subject were investigated. Then using Finite Element Method, potential and electricalfield distribution on a polluted insulator have been calculated. According to the calculated values, nodes which may cause discharges on insulator surface have been determined and controlled with flashover criteria. Propagation of time depended discharge causes on increase in the leakage current on insulator surface and results surface flashover. A computer program which considers all of this cases has been developed, The computer program can investigate the problem depend in both on the time and the conductivity variation. Electrical field strength variation on insulator surface, pollution resistance variations serial with arc and flashover voltages have been calculated and plotted. Then the results have been compared with other investigators results.

Benzer Tezler

  1. Sonlu elemanlar yöntemi yardımıyla yüksek gerilim izolatörlerinde yüzey alan dağılımının hesabı

    Computation of surface field distribution of high voltage insulators by the finite element method

    MEHMET ÇANAKÇI

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    Y.DOÇ.DR. MEHMET CEBECİ

  2. Yüksek gerilim izolatörlerinin kirlenme atlama davranışlarının sonlu elemanlar yöntemi yardımıyla belirlenmesi

    Determination of pollution flashover behaviour of high voltage insulators by the finite element method

    MUHSİN TUNAY GENÇOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ.DR. MEHMET CEBECİ

  3. Güç merkezi izolatörlerinde yüzey kaçak akımları için bir görüntü ve uyarı cihazının tasarımı

    Advancing of monitoring and alarm device for surface leakage currents an outdoor power plant insulators

    AHMET ŞENPINAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET CEBECİ

  4. Yüksek gerilim izolatörlerinin performansını belirlemese bir deneysel yöntem

    An experimental mehod to determine to performance of high voltage insulators

    ZEKERİYA ORAL YAĞDIRAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ.DR. MEHMET CEBECİ

  5. Na-feldspatin K-feldspattan flotasyonla ayrılmasında inorganik tuzların etki mekanizması

    Effect of inorganic salts on separation of Na-feldspar from K-feldspar by flotation

    CENGİZ DEMİR

    Doktora

    Türkçe

    Türkçe

    2001

    Maden Mühendisliği ve Madencilikİstanbul Teknik Üniversitesi

    PROF. DR. MEHMET SABRİ ÇELİK