Tam ark implant üstü restorasyonlar için farklı üretim teknolojisine sahip üç boyutlu yazıcılarla üretilen reçine modellerin doğruluk ve hassasiyetlerinin karşılaştırılması

Comparison of accuracy and precision of resin models fabricated using different 3D printing technologies for full-arch implant-supported restorations

  1. Tez No: 959777
  2. Yazar: GONCA ÖZER
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MUHAMMET ÇAĞLAR BURSA
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: implant üstü restorasyon, dental model üretimi, üç boyutlu yazıcılar, eklemeli üretim teknolojisi, implant-supported restoration, dental model fabrication, three-dimensional printers, additive manufacturing technology
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: İstanbul Aydın Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Son yıllarda diş hekimliği alanındaki dijital dönüşümün önemli bir parçası olan üç boyutlu yazıcı teknolojileri, karmaşık anatomik yapıların hassas üretimini mümkün kılarak, özellikle implant destekli rehabilitasyonların planlama ve üretim süreçlerinde önemli bir araç haline gelmiştir.Bu alanda vat fotopolimerizasyon esaslı yazıcı sistemleri oldukça yaygın olarak kullanılmaktadır. Ancak bu üretim çeşitliliğinin, modellerin doğruluğu üzerindeki etkisi hâlâ tartışmalıdır. Bu çalışmada, tam dişsiz ve 4 adet kemik seviyesi implant (Bioinfinity,UMG, Türkiye) bulunan epoksi modelden elde edilen referans alçı model endüstriyel optik tarayıcı (Solutionix C500,Medit,Kore) ile dijitalize edildi.Ardından tasarımı yapılan model DLP (S), MSLA (U), LCD (H) şeklinde üç farklı vat fotopolimerizasyon teknolojisine sahip yazıcı ile aynı fotopolimer reçine (PowerResin,3bfab, Türkiye) kullanılarak üretildi (n=45) . Üretilen modellerden elde edilen STL dosyaları, Geomagic Control X (v2022, 3D Systems, ABD) yazılımı aracılığıyla referans STL verisiyle karşılaştırıldı. Karşılaştırmalar, karekök ortalama karesi (RMS) değerleri, üç boyutlu renk haritaları, implantlar arası mesafe ölçümü (DİM), implantlar arası açısal değişimler (ADEV) ve bireysel implant açısal değişimleri (ANG) parametrelerine esasen yapıldı. Aynı zamanda, klinik olarak kritik öneme sahip olan üretim hassasiyeti de bu veriler doğrultusunda analiz edildi. İstatistiksel analizler NCSS 2007 (Kaysville, Utah, USA) yazılımı ile gerçekleştirildi; Shapiro-Wilk testi, one-way ANOVA ve tukey testleri uygulandı. Çalışmada RMS ölçümünde gruplar arasında anlamlı farklılıklar gözlendi . H grubunun RMS değeri diğer gruplara göre anlamlı düzeyde daha düşük bulundu (p<0.001). DİM ölçümlerinde belli bölgelerde anlamlı farklılıklar saptandı (p<0.001). Bu bölgelerde U grubunun değerleri, diğer gruplara kıyasla anlamlı düzeyde daha düşük bulundu. ADEV ölçümlerinde belli bölgeler arasında anlamlı fark olduğu görüldü (p<0.001). ADEV1 dışında U grubunun değerleri daha düşük bulundu. Çalışmada ANG ölçümlerinde gruplar arasında anlamlı farklılıklar tespit edildi (p<0.001). Bu ölçümlerde U grubunun değerleri, S ve H gruplarına göre istatistiksel olarak anlamlı düzeyde daha düşük bulundu. Hassasiyet analizlerinde RMS, DİM1, DİM2 ve ANG2 ölçümlerinde gruplar arasında istatistiksel olarak anlamlı farklılıklar saptandı. U grubunun RMS (p=0.011), DİM2 (p=0.007) ve ANG2 (p=0.038) değerlerinin, diğer gruplara kıyasla anlamlı düzeyde daha düşük olduğu görüldü.Bu da U grubunun üretim hassasiyetinin diğer gruplara göre daha yüksek olduğunu gösterdi. H grubu yüzey doğruluğunda en iyi sonucu verirken, U grubu mesafe ve açısal ölçümlerde daha doğru ve öngörülebilir sonuçlar sundu. Elde edilen bulgular, üretim teknolojisinin model doğruluğu üzerinde çok yönlü etkiler oluşturduğunu ve hiçbir teknolojinin tüm parametrelerde üstünlük sağlayamadığını ortaya koydu. Açısal ve doğrusal sapmaların son derece önemli olduğu implant üstü restorasyonları için model elde edilmesi konusunda üç boyutlu yazıcıların kullanımının hala gelişmesi gereken yönleri olduğu sonucuna varıldı.

Özet (Çeviri)

In recent years, three-dimensional printer technologies, which constitute a significant part of the digital transformation in the field of dentistry, have become an essential tool in the planning and manufacturing processes of implant-supported rehabilitations by enabling the precise fabrication of complex anatomical structures. In this domain, printer systems based on vat photopolymerization are widely utilized. However, the impact of this diversity in production technologies on the accuracy of the models remains a matter of debate. In this study, a reference gypsum model was obtained from an epoxy model representing edentulous jaw with four bone-level implants (Bioinfinity, UMG, Turkey), and digitized using an industrial optical scanner (Solutionix C500, Medit, Korea). The designed model was subsequently fabricated using three different vat photopolymerization technologies—DLP (S), MSLA (U), and LCD (H)—with the same photopolymer resin (PowerResin, 3bfab, Turkey) (n=45). The STL files obtained from the fabricated models were compared with the reference STL data using Geomagic Control X software (v2022, 3D Systems, USA). The comparisons were based on root mean square (RMS) error values, three-dimensional color mapping, inter-implant distance measurements (DİM), inter-implant angular deviations (ADEV), and individual implant angular deviations (ANG). Additionally, production precision, which is of critical clinical importance, was analyzed based on these parameters. Statistical analyses were performed using NCSS 2007 software (Kaysville, Utah, USA), applying the Shapiro-Wilk test, one-way ANOVA, and Tukey post hoc tests. The study revealed statistically significant differences among groups in RMS measurements. The RMS value of the H group was found to be significantly lower than those of the other groups (p<0.001). In DİM measurements, statistically significant differences were detected in certain regions (p<0.001). In these regions, the values in the U group were significantly lower compared to other groups. ADEV measurements also demonstrated significant differences among specific regions (p<0.001). Except for ADEV1, the values of the U group were found to be lower. ANG measurements revealed statistically significant differences among groups (p<0.001), with the U group presenting significantly lower values compared to the S and H groups. In precision analyses, statistically significant differences among groups were found in RMS, DİM1, DİM2, and ANG2 measurements. The values of the U group for RMS (p=0.011), DİM2 (p=0.007), and ANG2 (p=0.038) were significantly lower compared to the other groups. These findings indicated that the U group exhibited higher production precision than the others. While the H group yielded the best results in terms of surface accuracy, the U group produced more accurate and predictable outcomes in terms of distance and angular measurements. The findings suggest that the printing technology exerts multifactorial effects on model accuracy and that no single technology demonstrates superiority across all parameters. It was concluded that although 3D printers offer promise in producing models for implant-supported restorations—where angular and linear deviations are of utmost importance—there remain aspects that require further development.

Benzer Tezler

  1. Sivas'ta kadınların işgücüne katılım farklılıkları

    Başlık çevirisi yok

    BİNNUR ERCEM

    Yüksek Lisans

    Türkçe

    Türkçe

    1984

    SosyolojiCumhuriyet Üniversitesi

    Kurumlar Sosyolojisi Ana Bilim Dalı

    YRD. DOÇ. DR. FARUK KOCACIK

  2. Batı tesirine kadar Osmanlı mimarisinde estetik kriterler

    Başlık çevirisi yok

    LEYLA BAYDAR

    Doktora

    Türkçe

    Türkçe

    1986

    MimarlıkGazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. HALUK KARAMAĞARALI

  3. Sivas yöresinde akraba evliliği yapan ve yapmayan çiftlerde dermatoglifik benzerlikler

    Similarities of dermataoglyphies among individval of married relatives and married couples not related to each other in Sivas region

    Y. SELMA SÜNGÜ

    Yüksek Lisans

    Türkçe

    Türkçe

    1984

    Tıbbi BiyolojiCumhuriyet Üniversitesi

    Tıbbi Biyoloji ve Genetik Ana Bilim Dalı

    YRD. DOÇ. DR. İLHAN SEZGİN

  4. Laktat dehidrogenaz tayini için klinik kullanıma uygun yöntem araştırması

    The investigation of a suitable method for the determination of lactate dehidrogenase in routine analysis

    SEVTAP BAKIR ÇETİNTARAKÇI

    Yüksek Lisans

    Türkçe

    Türkçe

    1984

    BiyokimyaCumhuriyet Üniversitesi

    Biyokimya Ana Bilim Dalı

    YRD. DOÇ. DR. AHMET AKER

  5. Eksternal etmoidektomiler

    Başlık çevirisi yok

    ERCÜMENT AKMAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Kulak Burun ve BoğazGazi Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    PROF.DR. NECMETTİN AKYILDIZ