Aerobik selektörlü aktif çamur sisteminde ağır metal giderimi
Heavy metal removal in aerobic selector activated sludge
- Tez No: 95246
- Danışmanlar: Y.DOÇ.DR. UFUK ALKAN
- Tez Türü: Yüksek Lisans
- Konular: Çevre Mühendisliği, Environmental Engineering
- Anahtar Kelimeler: aerobik seçici, aktif çamur, adsorpsiyon, metal giderimi, bakır, krom (VI), hücre dışı polimer, biyosorpsiyon, Ağır metaller, Krom, aerobic selector, activated sludge, adsorption, metal removal, copper, hexavalent chromium, extracellular polymer, biosorption, Heavy metals, Chromium
- Yıl: 2000
- Dil: Türkçe
- Üniversite: Uludağ Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın temel amacı, aktif çamur sistemlerine ilave edilen aerobik seçicilerin, ağır metal biyosorpsiyonunu teşvik ederek ağır metal giderim verimini arttırıp arttırmadığım araştırmaktır. Laboratuvar ölçekli aktif çamur sistemlerinden alman çamurla kesikli sorpsiyon deneyleri yapılmıştır. Elde edilen sonuçlar, aerobik seçicili aktif çamur sisteminin klasik aktif çamur sisteminden daha fazla ağır metal giderme kapasitesine sahip olduğunu göstermiştir. Her iki sistemden alınan aktif çamurun bakıra, krom (VI)' dan daha yüksek bir eğilim gösterdiği tespit edilmiştir. Aktif çamurda ortalama giderim verimleri, Cu için %74, Cr (VI) için ise %37 oranında gerçekleşmiştir. Aktif çamurun metal adsorpsiyonlan Freundlich izotermine göre düzenlenmiştir. Metal gideriminin büyük kısmının ilk 15-30 dakikada gerçekleştiği, denge durumuna ise 3-8 saatte ulaştığı tespit edilmiştir. Freundlich izotermleri, aerobik seçicili sistemin adsorpsiyon kapasitesinin Cu+2 için %15, Cr (VI) için ise %30 oranında klasik sistemden daha yüksek olduğunu göstermiştir. Ayrıca kesikli deneylerden elde edilen sonuçlar, adsorpsiyonun pH değişimlerinden doğrudan etkilendiğini ve bu etkinin Cu+2 ve Cr (VI) metalleri için ters etki yaptıklarım göstermiştir.
Özet (Çeviri)
The overall objective of this study was to determine whether the installation of an aerobic selector enhanced biosorption of heavy metals, thus increasing the removal efficiency of the activated sludge system. Batch sorption experiments were conducted using sludge harvested from the continuous Lab-scale activated sludge systems. The results indicated that the selector sludge had a greater capacity of metal adsorption compared to that of the conventional system sludge. Affinities of metals for activated sludge from both systems were found to be greater for Cu than that of Cr (VI). Average removal efficiencies by activated sludge appeared to be 74% and 37 % for Cu+2 and Cr (VI), respectively. Adsorptions of metals by activated sludge were fitted to Freundlich equilibrium isotherm. The majority of metal uptake occurred within the first 15-30 minutes and equilibrium was attained in 3-8 hours. Freundlich isotherms suggested that the adsorption capacity of selector system sludge in comparison to conventional system sludge was 15 % and 30 % greater for Cu+2 and Cr (VI), respectively. The results of the batch experiments also showed that adsorptions of Cu+2 and Cr (VI) were pH dependent; the effect being reverse for the two metals examined.
Benzer Tezler
- Atık suların mikrobiyolojik yolla arıtılması
Wastewater treatment by microbiological methods
HÜLYA S. BÖKE
Yüksek Lisans
Türkçe
1988
Çevre MühendisliğiOndokuz Mayıs ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
DOÇ. DR. HANİFE BÜYÜKGÜNGÖR
- Effects of continuous and interval running programs on aerobic and anaerobic capacities of highschoolboys aged 14-16 years
Başlık çevirisi yok
ÖMER ŞENEL
Yüksek Lisans
İngilizce
1991
SporOrta Doğu Teknik ÜniversitesiBeden Eğitimi ve Spor Ana Bilim Dalı
DOÇ. DR. KEMAL TAMER
- Hentbolde fizyolojik faktörler“aerobik güç, anaerobik güç ve vücut kompozisyonu ile antrenman ilişkisi”
Physiological factors in handball "the effect of training on aerobic power, anaerobic power and body composition
İLHAN ERKAN