Geri Dön

İmplant yerleşim derinliğinin, posterior diş varlığının ve farklı tarama stratejilerinin dijital ölçü doğruluğu ve hassasiyeti üzerine etkisi

The impact of implant placement depth, posterior tooth presence and scanning strategies on accuracy and precision of partial edentulism

  1. Tez No: 932201
  2. Yazar: BÜŞRA BOZDOĞAN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ ESRA TALAY ÇEVLİK, DOÇ. DR. MEHMET ESAD GÜVEN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dijital ölçü doğruluğu, İmplant yerleşim derinliği, Kısmi dişsizlik, Tarama stratejisi, Digital impression accuracy, Implant placement depth, Partial edentulism, Scanning strategy
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Aydın Adnan Menderes Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Farklı implant yerleşim derinliklerine sahip kısmi dişsiz üst çene modellerinin farklı tarama stratejileri ile elde edilen tarama verilerinin doğruluğunu ve hassasiyetini değerlendirmektir. Gereç ve Yöntem: Kennedy sınıf II, modifikasyon I kısmi dişsizliğini taklit eden iki poliüretan üst çene modelinde (M1, M2) implantlar iki farklı derinlikte (1 mm, 3 mm) yerleştirilmiştir. Ağız içi tarayıcı ile dört farklı stratejisi (S1, S2 (okluzal-bukkal-palatinal); S3, S4 (zigzag)) uygulanarak elde edilen seksen veri seti, laboratuvar tarayıcısı ile elde edilen referans tarama verileri ile hizalanmıştır. Kare ortalamaların karekökü (RMS), doğrusal, z ekseninden doğrusal, açısal ve implantlar arası mesafe sapma analizleri yapılmış, istatistiksel değerlendirmelerde 2×4 faktöriyel ANOVA ve Bonferroni testi ile korelasyon analizleri kullanılmıştır. Bulgular: Tarama stratejileri Model 1'de tüm model RMS ve 16 RMS üzerinde, Model 2'de tüm model RMS, 16 ve 26 RMS değerlerinde anlamlı fark tespit edilmiştir (p<0,05). 16 ve 24 numaralı implantların doğrusal sapmaları modeller arasında farklılık göstermiştir (p<0,05). RMS ile doğrusal sapma arasında pozitif korelasyon vardır (p<0,05). Tarama stratejilerinin açısal sapmalar üzerinde anlamlı etkisi bulunmazken, 14-24 ve 16-26 implantlar arası mesafe sapma değerlerinde S1 ve S4 arasında anlamlı fark gözlenmiştir (p<0,05) Sonuçlar: İmplant yerleşim derinliği ve tarama stratejileri, dijital ölçü doğruluğunu etkileyen faktörlerdir. Daha derin implantlarda daha yüksek RMS değerleri bulunmuştur. Posterior diş varlığı tarama doğruluğunu artırmıştır. Okluzal-bukkal-palatinal tarama stratejileri, zigzag tarama stratejilerinden daha yüksek doğruluk sağlamıştır. Klinik uygulamalarda ölçü doğruluğunu optimize etmek için uygun strateji seçimi önemlidir.

Özet (Çeviri)

Aim: To evaluate the accuracy and precision of scan data obtained from partially edentulous maxillary models with different implant placement depths using different scanning strategies. Materials and Methods: Implants were placed at two different depths (1 mm, 3 mm) in two polyurethane maxillary models (M1, M2) simulating Kennedy Class II, modification I partial edentulism. A total of eighty datasets were obtained by applying four different scanning strategies (S1, S2 (occlusal-buccal-palatal); S3, S4 (zigzag)) using an intraoral scanner, and these datasets were aligned with reference scan data obtained using a laboratory scanner. Analyses of root mean square (RMS), linear, z-axis linear, angular, and inter-implant distance deviations were performed, and statistical evaluations were conducted using 2×4 factorial ANOVA, Bonferroni post-hoc tests, and correlation analyses. Results: Scanning strategies showed significant differences in all-model RMS and 16 RMS in Model 1, and in all-model RMS, 16 RMS, and 26 RMS in Model 2 (p<0.05). Linear deviations of implants 16 and 24 differed significantly between the models (p<0.05). A positive correlation was observed between RMS and linear deviation (p<0.05). While scanning strategies had no significant effect on angular deviations, a significant difference was observed between S1 and S4 in inter-implant distance deviations for implants 14-24 and 16-26 (p<0.05). Conclusion: Implant placement depth and scanning strategies are factors that affect the accuracy of digital impression. Greater RMS values were observed in association with deeper implant placements. The presence of posterior teeth improved scanning accuracy. Occlusal-buccal-palatal scanning strategies provided higher accuracy compared to zigzag scanning strategies. Selecting the appropriate strategy is important for optimizing impression accuracy in clinical applications.

Benzer Tezler

  1. Comparıson of bıoactıvıtıes of Ti6Al4V ımplants after multıple surface treatments

    Çoklu yüzey işlemleri uygulanan Ti6Al4V implantların biyoaktivitelerinin karşılaştırılması

    NEŞE BENAY SEKEN

    Yüksek Lisans

    İngilizce

    İngilizce

    2025

    Mühendislik Bilimleriİstanbul Teknik Üniversitesi

    Nanobilim ve Nanomühendislik Ana Bilim Dalı

    PROF. DR. NİLGÜN BAYDOĞAN

  2. Maksilla anterior bölgede immediyat implant yerleştirilmesi ile ilişkili kemik greftlemesi ihtiyacının konik ışınlı bilgisayarlı tomografi ile değerlendirilmesi

    Evaluation of the need for bone grafting associated with immediate implant placement in the maxillary anterior region using cone beam computed tomography

    MİNE ŞENKAL KAŞIKÇI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiKocaeli Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. BERKAY TOKUÇ

  3. Development of mirna biomarkers for the differentiation between gingivitis and periodontitis: A pilot study

    Gingivitis ve periodontitis ayrımı için mirna biyobelirteçlerinin geliştirilmesi: Pilot çalışma

    DHAFIR LATIEF FAYADH FAYADH

    Doktora

    İngilizce

    İngilizce

    2023

    BiyokimyaSüleyman Demirel Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CALAPOĞLU

  4. Dental İmplant Destekli Protezlerde İmplant Sayısının Ve Yerleşim Şeklinin Sonlu Elemanlar Metoduyla Analizi

    Effect of implant number and implant position on stress distribution in implant retained overdenture prothesis

    TOLGA TOPKAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Makine MühendisliğiFırat Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MURAT YAVUZ SOLMAZ

  5. Farklı altyapılı implant destekli protezlerde kanat yerleşimi ve uzunluğunun stres dağılımına etkisinin sonlu elemanlar analizi ile değerlendirilmesi

    Evaluation of the effect of cantilever placement and length on stress distribution in implant supported prostheses with different frameworks via finite element analysis

    ŞAFAK TANYERİ

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. VOLKAN TURP