Tek üye implant restorasyonlarda farklı yüzey bitirme işlemlerinin üç boyutlu baskı ile üretilen kalıcı kronların klinik başarısına etkisinin araştırılması
Evaluation of the effect of different surface finishing procedures on the clinical success of definitive crowns fabricated by 3D printing in single crown implant restorations
- Tez No: 905255
- Danışmanlar: PROF. DR. MİNE DÜNDAR ÇÖMLEKOĞLU
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2024
- Dil: Türkçe
- Üniversite: Ege Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çalışmamızda 3D baskılı seramik dolduruculu kalıcı reçine kronların fonksiyon ve estetik kaybı olmadan ağızda kalabilme yeteneğini araştırmak, farklı yüzey bitirme işlemlerinin restorasyonların klinik başarısındaki etkisini incelemek, implant-dayanak-kron bileşkesini değerlendirmek ve kronların zamana bağlı oklüzal aşınma potansiyelini incelenmek amaçlanmıştır. Ayrıca implant cerrahisi sırasında yerleştirilen iyileşme başlıklarının osseointegrasyon sonrası tersine tork değerleri değerlendirilmiştir. Restorasyonların yarısına (n=20) mekanik parlatma, diğer yarısına (n=20) glazür yüzey işlemi uygulanmıştır. Çalışma iki aşamada planlanmıştır. Cerrahi Aşama: 30 hastaya 40 adet konik bağlantılı implant yerleştirildi. Operasyon sırasında 15 Ncm tork değeriyle iyileşme başlıkları takıldı. 16 haftalık osseointegrasyon sonrası iyileşme başlıklarının tersine tork değerleri ölçülüp yükleme protokolleri başlatıldı. Protetik aşama: Dijital ölçüler ağız içi optik tarayıcı kullanılarak kaydedildi. Her hastaya özel laboratuvarda tasarlanan restorasyonlar, 3D baskılı kalıcı hibrid reçine materyaliyle üretildi. Restorasyonların yarısına (n=20) üretim sonrasında mekanik, diğer yarısına (n=20) glazür yüzey işlemi uygulandı. Restorasyonlar 30 Ncm tork değeriyle ağız içerisine vida ile sabitlendi. Restorasyonların klinik başarıları; Modifiye USPHS, Modifiye FDI ve implant-dayanak (abutment)-kron bileşkesi kriterlerine göre değerlendirilerek (0:başlangıç, 6. ay) kaydedilen verilere istatistiksel analiz uygulandı. Mekanik cilalanmış ve glazür uygulanmış kronların yüzey pürüzlülüğü ölçümleri taşınabilir profilometre kullanılarak kaydedildi. Ayrıca, dijital görüntüler optik tarama cihazı yardımıyla görüntü çakıştırma programına aktarılarak, kronların çiğneyici yüzeylerindeki zamana bağlı aşınma miktarı ölçülüp analiz edildi. İyileşme başlıklarının tork değerleri ölçümleri arasında istatistiksel olarak anlamlı fark bulunmuştur (p<0.05). Başlangıç tork değerleri tersine tork değerlerinden daha yüksektir. Ortalama tersine tork değeri (ortalama ± s.s. = 7,7±4,93) şeklindedir. İmplant-dayanak (abutment)-kron bileşkesine ilişkin kriterlerin karşılaştırılmasında istatistiksel analiz yapılmıştır. Analizlerde istatistiksel olarak anlamlı fark bulunmuştur (p<0,05). Kriterlerin çoğunlukla değişmediği; değişen kriterlerin ise M-materyal (kron) kırığı olduğu görülmüştür. Çalışma grupları ve yüzeyler için yapılan analizler sonucunda tüm pürüzlülük ölçümlerinde zamana göre istatistiksel olarak anlamlı farklılıklar gözlenmiştir (p<0,05). Tüm ölçümlerde pürüzlülüğün zamanla arttığı gözlenmiştir. Çalışma grupları için yapılan analizlerde iki grupta da yüzeye göre pürüzlülük değişim miktarları arasında istatistiksel olarak anlamlı farklılıklar gözlenmemiştir (p>0,05). Yüzeyler için yapılan analizlerde, çalışma gruplarına göre 6. aydaki vestibül yüzey pürüzlülüğü ölçümleri arasında istatistiksel olarak anlamlı fark bulunmuştur (p<0.05). Glazür cila grubunun ölçümleri mekanik cila grubunun ölçümlerinden daha yüksektir. Çalışma gruplarına göre 6. aydaki aproksimal ve oklüzal yüzey pürüzlülük ölçümleri arasında ve tüm yüzeylerin başlangıç pürüzlülük ölçümleri arasında istatistiksel olarak anlamlı fark elde edilmemiştir (p>0.05) Analizler sonucunda, çalışma gruplarına göre oklüzal aşınma ölçümleri arasında istatistiksel olarak anlamlı fark elde edilmemiştir (p>0.05). Yüzey pürüzlülüğü ile oklüzal aşınma ölçümleri arasında tüm zamanlarda ve gruplarda istatistiksel olarak anlamlı ilişkiler elde edilmemiştir (p>0.05). Modifiye USPHS kriterlerinin glazür ve mekanik cila gruplarında başlangıçta ve 6. ay sonunda benzer seviyelerde olduğu görülmüştür. Modifiye FDI kriterlerinin başlangıçta glazür ve mekanik cila gruplarında benzer seviyelerde olduğu görülmüştür. 6. ayda Modifiye FDI kriterlerinden okluzal kontur/aşınma düzeyleri ve aproksimal anatomik form düzeylerinin mekanik cila grubunda daha düşük oranda başarısız olduğu tespit edilmiştir. 6. aydaki diğer Modifiye FDI kriterlerinin glazür ve mekanik cila gruplarında benzer seviyelerde olduğu görülmüştür. Çalışmamızda bu değerlendirmeler incelendiğinde yüzey bitirme işlemleri arasında anlamlı farklılıklar tespit edilmemiştir. 3D baskılı kalıcı hibrid reçine restorasyonların tek üye implant üstü protezlerde rutin materyal olarak tercih edilebilmesi için daha uzun süreli ve çok sayıda klinik araştırmaya gereksinim vardır.
Özet (Çeviri)
In our study, the ability of 3D printed ceramic-filled permanent resin crowns' survival without loss of function and aesthetics, the effect of different surface finishing processes on the clinical success of the restorations, the implant-abutment-crown junction and time-dependent occlusal wear potential of the crowns were examined. In addition, the anti-torque values of the healing caps placed during implant surgery after osseointegration were evaluated. Half of the restorations (n=20) underwent mechanical polishing and the other half (n=20) glaze surface treatment. The study was planned in two phases. Surgical Phase: 40 implants with conical connection were placed in 30 patients. Healing caps with a torque value of 15 Ncm were attached during the operation. After 16 weeks of osseointegration, reverse torque values of the healing caps were measured and loading protocols were initiated. Prosthetic stage: Digital impressions were recorded using an intraoral optical scanner. Restorations designed in the laboratory for each patient were fabricated with a 3D printed permanent hybrid resin material. Half of the restorations (n=20) were mechanically polished and the other half (n=20) were glazed after fabrication. The restorations were fixed with screws in the mouth with a torque value of 30 Ncm. The clinical success of the restorations was evaluated according to Modified USPHS, Modified FDI and implant-abutment-crown junction criteria (0: initial, 6 months) and statistical analyses were performed. Surface roughness measurements of mechanically polished and glazed crowns were recorded using a portable profilometer. In addition, digital images were transferred to an image registration programme using an optical scanning device and the amount of wear on the chewing surfaces of the crowns was measured and statistically analysed. A significant difference was found between the torque values of the healing caps (p<0.05). Initial torque values were higher than the anti-torque values. The mean anti-torque value was (mean ± s.s. = 7.7±4.93). The implant-abutment-crown junction criteria were compared and significant differences were observed (p<0.05) in that, the criteria were mostly unchanged except for M-material (crown) fracture. As a result of the analyses performed for the study groups and surfaces, significant differences were observed in all time-related roughness measurements (p<0.05). The roughness increased in time in all measurements. For the study groups, no significant differences were observed between the amounts of roughness according to the surface treatments in both groups (p>0.05). For the surfaces, a significant difference was found between the vestibular surface roughness measurements at the 6th month according to the study groups (p<0.05). The measurements of the glazed group were higher than the measurements of the mechanical polishing group. There were no significant differences between the aproximal and occlusal surface roughness measurements at 6 months and between the initial roughness measurements of all surfaces according to the study groups (p>0.05). As a result of the analyses, no significant differences were obtained between occlusal wear measurements according to the study groups (p>0.05). No significant relationships were obtained between surface roughness and occlusal wear measurements at all times and groups (p>0.05). Modified USPHS criteria were found to be at similar levels in the glazed and mechanical polishing groups at baseline and at the end of 6th months. Modified FDI criteria were found to be at similar levels in glazed and mechanical polishing groups at baseline. At 6 months, the Modified FDI criteria of occlusal wear levels and aproximal anatomical form levels were found to fail at a lower rate in the mechanical polishing group. At the 6th month, other Modified FDI criteria were found to be at similar levels in the glazed and mechanical polishing groups. Overall, no significant differences were found between the surface finishing processes. Further long term clinical research is required in the preference of 3D printed permanent hybrid resin restorations as a definitive restorative material in single-unit implant-retained prostheses.
Benzer Tezler
- Poli-eter-eter-keton (PEEK) ve poli-eter-keton-keton (PEKK) ile üretilmiş altyapılarda konnektör kalınlığının kırılma direncine etkisinin değerlendirilmesi
Evaluation of the effect of connector thickness on fracture strength in framework manufactured with poly-ether-ether-ketone (PEEK) and poly-ether-ketone-ketone (PEKK)
FULYA BÜLTE
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiHatay Mustafa Kemal ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. MUSTAFA ZORTUK
- Tekrarlanan fırınlama işleminin zirkonya kronların marjinal uyum ve optik özelliklerine etkisinin araştırılması
Investigation of the effect of repeated firing on the marginal fit and optical properties of zirconia crowns
AYŞEGÜL ÜÇDAL ASLAN
Diş Hekimliği Uzmanlık
Türkçe
2024
Diş HekimliğiUşak ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. BENGİSU YILDIRIM
- Mandibular posterior bölgede farklı üst yapı materyalleri ile restore edilmiş kısa implant destekli tek üye restorasyonlarda stres dağılımının sonlu eleman analizi yöntemi ile incelenmesi
Evaluation of stress distribution in short dental implants with different superstructure materials: A finite element analysis
BUSE KARATAY ŞİBAL
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. GÜLCAN COŞKUN AKAR
- Üst çene üç implant üstü beş üye restorasyonlarda; farklı implant materyali, lokalizasyonu ve abutment yüksekliklerinin; implant, abutment, restorasyonlar ve çevre dokular üzerindeki stres dağılımının sonlu elemanlar stres analizi ile değerlendirilmesi
Five members over three upper implant restorations; different implant material, localization and abutment heights; evaluation of stress distribution on implant, abutment, restorations and environmental tissues with finite element stress analysis
MEHMET EMEKLİ
Diş Hekimliği Uzmanlık
Türkçe
2020
Diş HekimliğiFırat ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ TAHİR KARAMAN
- CAD-CAM materyalleri ile üretilen implant üstü restorasyonların farklı siman aralıklarındaki stres dağılımlarının karşılaştırılması
Comparison of stress distributions in different cement thicknesses of implant- retained fixed restorations produced with current CAD-CAM materials
RAZİYE YILDIZ
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. AYŞE GÖZDE TÜRK