Geri Dön

مقایسه اعتبار روش های میکرولنفوسایتوتوکسیسیتی و فلوسایتومتری با PCR برای تشخیص آنتی ژن HLA-B27 در بیماران مبتلا به بیماران اسپوندیلیت آنکیلوزانت

Ankilozan spondilitli hastalarda HLA-B27 antijeninin saptanması için mikrolenfositotoksisite ve akış sitometri yöntemlerinin geçerliliğinin PCR ile karşılaştırılması

  1. Tez No: 900765
  2. Yazar: MAZDAK GANJALI KHANI HAKEMI
  3. Danışmanlar: Prof. Dr. MOHAMMAD HOSSEİN NİKNAM
  4. Tez Türü: Yüksek Lisans
  5. Konular: Romatoloji, Allerji ve İmmünoloji, Rheumatology, Allergy and Immunology
  6. Anahtar Kelimeler: HLA B27 antijeni, Spondilit-ankilozan, HLA B27 antigen, Spondylitis-ankylosing
  7. Yıl: 2002
  8. Dil: Farsça
  9. Üniversite: Tehran Unıversıty Of Medıcal Scıences
  10. Enstitü: Yurtdışı Enstitü
  11. Ana Bilim Dalı: İmmünoloji Ana Bilim Dalı
  12. Bilim Dalı: İmmünoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

İnsan doku adaptasyon kompleksi (MHC); organ nakli, kan transfüzyonu ve Abbott ret testinde oldukça önemli bir faktör olmasının yanı sıra farklı HLA antijenlerinin farklı hastalıklarla bağlantılı olmaları nedeni ile bireylerin hastalıklara yatkınlıklarının değerlendirilmesinde / saptanmasında değerli katkıları söz konusudur. Yapılan araştırma sonuçlarına göre HLA-B27 antijeninin varlığı ile başta Ankilozan spondilit olmak üzere Spondilo artropatiler ile çok yakın ilişkileri olduğunu ortaya koymuştur. HLA antijenin tespitinde / saptanmasında farklı yöntemler kullanılmaktadır. En yaygın kullanılan yöntemler; Mikrolenfo sitotoksisite, Flow sitometri ve PCR dir. Bu çalışmanın amacı HLA-B27 tayininde Mikrolenfo sitotoksisite ve Flow sitometri yöntemlerinin özgüllük / spesifite, hassasiyet / sensitivite, yalancı pozitiflik ve yalancı negatiflik değerlerinin standart altın / referans PCR yöntemi ile karşılaştırılmasıdır. İlk iki yöntem hücresel yüzeyde antijenin yapısını tespit etmektedir. Bu nedenle söz konusu yöntemlerde interferanslar nedeni ile yalancı pozitif ve / veya yalancı negatif sonuçlar elde edilebilir. Buna karşın PCR yöntemi gen sekansı tespitine dayalı olduğundan interferanslardan etkilenmeyip özgüllük / spesifite ve hassasiyet/sensitivite değerleri tamdır. Bu çalışmada 36 Ankilozan spondilit hasta kanı (hassasiyet / sensitivite tayini için yüksek ihtimal HLA-B27 pozitif popülasyon) ve 31 sağlıklı birey kanı (özgüllük / spesifite tayini için yüksek İhtimal HLA-B27 pozitif popülasyon) ayrı ayrı her 3 yöntemle test edildi. Mikrolenfo sitotoksisite ve Flow sitometri teslerde HLA-B27 antijenine karşı monoklonal antikor ve anti serumlar kullanılarak gerçekleştirildi. PCR testinde ise HLA-B27 geni 3 no.lu ekson özel bölgesi primerleri kullanılarak Allel spesifik PCR yöntemi kullanıldı. Çalışmanın sonuçlarına göre Mikrolenfo sitotoksisite yöntemi ile PCR tekniği karşılaştırıldığında sonuçların özgüllük / spesifite, hassasiyet/sensitivite, yalancı pozitiflik ve yalancı negatiflik değerleri sırasıyla %83,3-%100,%100 ve %88,1 olarak tespit edilmiştir. Flow sitometri yöntemi ile PCR tekniği karşılaştırıldığında sonuçların özgüllük/spesifite, hassasiyet / sensitivite, yalancı pozitiflik ve yalancı negatiflik değerleri sırasıyla %100 %94,6, %93,8 ve %100 olarak tespit edilmiştir. Öte yandan bu çalışma sonucunda PCR testi ile Ankilozan spondilit hastaların %69,4 'ünde HLA-B27 antijeni pozitif oldukları tespit edilmiştir. Yukarıda belirtilen sonuçlar dikkate alındığında Mikrolenfo sitotoksisite yöntemi ile karşılaştırıldığında Flow sitometrik yönetimlerinin daha güvenilir sonuçların elde edildiği, bu yöntemin standart Altın / referans PCR yöntemi ile aynı hassasiyet / sensitiviteye sahip olduğu, buna karşın ender olsa da yalancı pozitif sonuçlarının elde edildiği tespit edilmiştir. Ancak Flow sitometrik yönteminde kullanım ve yorumlama deneyiminin yükseltilmesi ile bu ve buna benzer olumsuzlukların giderilmesi de mümkündür.

Özet (Çeviri)

Human tissue adaptation complex (MHC); In addition to being a very important factor in organ transplantation, blood transfusion and Abbott rejection test, it also makes valuable contributions to the evaluation / determination of individuals' predisposition to diseases due to the association of different HLA antigens with different diseases. According to the results of the research, it has been revealed that the presence of HLA-B27 antigen is very closely related to Spondyloarthropathies, especially Ankylosing spondylitis. Different methods are used in the detection of HLA antigen. The most commonly used methods are Microlymphocyte cytotoxicity, Flow cytometry and PCR. The aim of this study is to compare the specificity, sensitivity, false positivity and false negativity values ​​of Microlymphocyte cytotoxicity and Flow cytometry methods in the determination of HLA-B27 with the standard gold / reference PCR method. The first two methods detect the structure of the antigen on the cellular surface. Therefore, false positive and / or false negative results can be obtained due to interferences in these methods. On the other hand, since the PCR method is based on gene sequence detection, it is not affected by interferences and its specificity and sensitivity values ​​are full. In this study, 36 Ankylosing spondylitis patient blood (high probability HLA-B27 positive population for sensitivity determination) and 31 healthy individual blood (high probability HLA-B27 positive population for specificity determination) were tested separately with each of the 3 methods. Microlymphocytotoxicity and Flow cytometry tests were performed using monoclonal antibodies and antisera against HLA-B27 antigen. In the PCR test, Allele specific PCR method was used using primers of HLA-B27 gene exon 3 special region. According to the results of the study, when the microlympho cytotoxicity method was compared with the PCR technique, the specificity/specificity, sensitivity, false positivity and false negativity values ​​of the results were determined as 83.3%-100%, 100% and 88.1%, respectively. When the flow cytometry method was compared with the PCR technique, the specificity/specificity, sensitivity, false positivity and false negativity values ​​of the results were determined as 100%, 94.6%, 93.8% and 100%, respectively. On the other hand, as a result of this study, it was determined that 69.4% of Ankylosing spondylitis patients were HLA-B27 antigen positive with the PCR test. Considering the above mentioned results, it has been determined that Flow cytometric methods provide more reliable results compared to the Microlymph cytotoxicity method, that this method has the same sensitivity / sensitivity as the standard Gold / reference PCR method, but that false positive results are obtained, although rare. However, it is possible to eliminate these and similar negativities by increasing the experience of using and interpreting the Flow cytometric method.

Benzer Tezler

  1. مقایسه سبک های دلبستگی، شیوه های حل تعارض و هیجان خواهی در مردان با و بدون گرایش به خیانت زناشویی

    Evlilik dışı ilişki eğilimine sahip ve sahip olmayan erkeklerde bağlanma stilleri, çatışma çözme yöntemleri ve heyecan arayışının karşılaştırılması

    SIAMAK KHOSHAGHIDEH

    Yüksek Lisans

    Farsça

    Farsça

    2022

    PsikolojiIran Unıversıty Of Medıcal Scıences

    Psikoloji Ana Bilim Dalı

    DR. ABBAS ABOLGHASEMI

  2. مقایسه سختی موثر تیر و ستون در تحلیل قابهای بتنی مسلح با ضرایب پیشنهادی آیین نامه ها

    Betonarme çerçevelerin analizinde kiriş ve kolonların efektif rijitliklerinin yönetmeliklerde önerilen katsayılarla karşılaştırılması

    REZA SALEH AHARI

    Yüksek Lisans

    Farsça

    Farsça

    2009

    İnşaat MühendisliğiIslamıc Azad Unıversıty

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. MOHAMMAD ALİ LOTFOLLAHİ

  3. تحلیل و مقایسه شیوه های آموزش زبان فارسی در ترکیه و ایران و تالش برای بهسازی آن

    Analysis and comparison of Persian language teaching methods in Turkey and Iran and efforts to improve it

    BÜLENT AKDAĞ

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Eğitim ve ÖğretimUnıversıty Of Tehran

    DR. ABDOLREZA SEİF

    DR. OMİD MAJD