Geri Dön

Yapay zeka analiz destekli kapalı ortam hava kalitesinin sağlık üzerine etkilerinin araştırılması

Artificial intelligence analysis supported investigation of the effects of indoor air quality on health

  1. Tez No: 886505
  2. Yazar: YUSUF BEKTAŞ
  3. Danışmanlar: DOÇ. DR. SELÇUK SARIKOÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Mühendislik Bilimleri, Engineering Sciences
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Amasya Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Teknoloji ve İnovasyon Yönetimi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Okullarda iç mekan hava kirleticileriyle ilişkili sağlık etkileri içinde, solunum yolu enfeksiyonları (SYE) riskinde artış ve Hasta Bina Sendromu (HBS) önemli yer tutmaktadır. Bu çalışmada bir lisede iç hava kalitesinin solunum yolu enfeksiyonları insidansı, hasta bina sendromu, devamsızlıklar üzerine etkisinin belirlenmesi ve iç mekanların hava kalite indeksinin tahmin edilebilmesi amacıyla hava kalitesi ölçüm sistemi tasarımı ve sensörlerden elde edilen veriler ile yapay zekaya dayalı model olarak bir derin öğrenme ağı geliştirilmesi amaçlanmıştır. Kesitsel tipteki bu çalışmanın evrenini Samsun'da bir lisede öğrenim gören 774 lise öğrencisi oluşturdu. Veri toplama işlemi 28/11/2022-16/06/2023 tarihleri arasında gerçekleştirildi. Basit rastgele yöntem kullanılarak iki adet atölye sınıfı seçildi ve toplamda 118 gün iş günü boyunca karbondioksit (CO2), sıcaklık, nem ve partiküler madde (PM) ölçümleri, bu çalışma kapsamında yazılımı ve elektronik tasarımı özel hazırlanmış hava kalitesi ölçüm sistemi ile yapıldı. Ölçümlerin tamamlanmasını takiben öğrencilere yönelik olarak anket formu uygulandı. Anketin ilk bölümünde araştırmacılar tarafından hazırlanan sosyodemografik veri formu ve SYE geçirme durumuna ilişkin soru formu, ikinci bölümünde ise HBS belirtilerinin saptanması amacıyla MM 060 NA School ölçeği yer aldı. Anket bilgilerinin yanı sıra örnekleme alınan öğrencilerin devamsızlık bilgileri temin edildi. Toplam 79 öğrenci arasında HBS prevalansı %8,9, en az bir defa SYE geçirdiğini belirten kişi sayısı 14 (%17,7) olarak belirlendi. Okulun genelinde senelik ortalama bağıl nem için %47,6, sıcaklık için 24,8°C, CO2 için 1433,7 ppm, PM1 için 15,1 μg/m3, PM2.5 için 22,3 μg/m3, PM10 için 31,1 μg/m3 olarak ölçüldü. Yapılan lojistik regresyon analizinde, sigara içmenin SYE geçirme riskini 8,0 kat arttırdığı belirlendi. Nem ve sıcaklık dışındaki tüm iç ortam hava kalitesi değişkenleriyle, raporlu devamsızlıklar arasında düşük derecede pozitif yönde korelasyon belirlendi. CO2 ve PM2.5'un limiti aştığı günleri takip eden günlerde raporlu devamsızlıkların daha yüksek olduğu görüldü. Yapay zekaya dayalı tahmin modelleri ile ilgili olarak, LSTM'de daha düşük hata oranları elde edildi ve her iki veri seti için de %81,25'lik doğruluk oranını elde edildi. İç ortam hava kalitesinin SYE ve HBS gelişimi üzerine anlamlı bir etkisi bulunamamış ancak CO2 ve PM artışının, raporlu devamsızlıkları düşük düzeyde arttırdığı gözlenmiştir. Etkin havalandırmanın sağlanması için otomatik bir şekilde devreye giren iklimlendirme teknolojilerinin kullanımı hayata geçirilebilir.

Özet (Çeviri)

Among the health effects associated with indoor air pollutants in schools, the increased risk of respiratory tract infections (RTI) and Sick Building Syndrome (SBS) have an important place. This study aimed to determine the effect of indoor air quality on the incidence of respiratory tract infections, sick building syndrome, and absenteeism in a high school, to design an air quality measurement system to estimate the air quality index of indoor spaces, to develop a deep learning network as an artificial intelligence-based model with data obtained from sensors. Two workshop classes were selected using the simple random method. During a total of 118 working days, carbon dioxide (CO2), temperature, humidity and particulate matter (PM) were measured with an air quality measurement system whose software and electronic design were specially prepared for this study. Following the completion of the measurements, a survey form was administered to the students. The first part of the survey included the sociodemographic data form and the questionnaire regarding RTI prepared by the researchers, and the second part included the MM 060 NA School scale to detect SBS symptoms. In addition to the survey information, absenteeism information of the sampled students was provided. Among a total of 79 students, the prevalence of SBS was 8.9%, and the number of people who stated that they had RTI at least once was 14 (17.7%). The annual average values across the school were measured as 47.6% for relative humidity, 24.8°C for temperature, 1433.7 ppm for CO2, 15.1 μg/m3 for PM1, 22.3 μg/m3 for PM2.5, and 31.1 μg/m3 for PM10. In the logistic regression analysis, it was determined that smoking increased the risk of having an RTI by 8.0 times. A low positive correlation was determined between illness-related absences and all indoor air quality variables except humidity and temperature. It was observed that absences due to illness were higher in the days following the days when CO2 and PM2.5 exceeded the limit. Regarding AI-based prediction models, lower error rates were achieved in LSTM, achieving an accuracy rate of 81.25% for both datasets. No significant effect of indoor air quality on the development of RTI and SBS was found, but it was observed that the increase in CO2 and PM increased sickness-related absences at a low level.

Benzer Tezler

  1. Energy efficiency and security of rıs-aided communication networks

    Ris-tabanli haberleşme ağlarinda enerji verimliliği ve güvenlik

    HAKAN ALAKOCA

    Doktora

    İngilizce

    İngilizce

    2025

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Bilişim Uygulamaları Ana Bilim Dalı

    PROF. DR. LÜTFİYE DURAK ATA

  2. Index modulation based designs, error performance and physical layer security analyses for unmanned aerial vehicle networks

    İnsansız hava aracı ağları için indis modülasyonu tabanlı tasarımlar, hata performansı ve fiziksel katman güvenlik analizleri

    AYŞE BETÜL BÜYÜKŞAR

    Doktora

    İngilizce

    İngilizce

    2024

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    PROF. DR. İBRAHİM ALTUNBAŞ

  3. Buğdayda farklı melezleme teknikleri kullanarak tohum tutma oranının saptanılması

    Başlık çevirisi yok

    İSMAİL TÜZÜN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    ZiraatUludağ Üniversitesi

    Tarla Bitkileri Ana Bilim Dalı

    PROF. DR. HALİS RUHİ EKİNGEN

  4. Sivas yöresinde akraba evliliği yapan ve yapmayan çiftlerde dermatoglifik benzerlikler

    Similarities of dermataoglyphies among individval of married relatives and married couples not related to each other in Sivas region

    Y. SELMA SÜNGÜ

    Yüksek Lisans

    Türkçe

    Türkçe

    1984

    Tıbbi BiyolojiCumhuriyet Üniversitesi

    Tıbbi Biyoloji ve Genetik Ana Bilim Dalı

    YRD. DOÇ. DR. İLHAN SEZGİN

  5. Akaryakıtla çalışan endüstriyel tav fırınlarında yanma, sıcaklık ve basıncın optimum kontrolu

    Optimum control of combustion temperature and pressure in industrial tempering furnaces working with fuel-oil

    MEHMET EROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Makine MühendisliğiGazi Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. YÜCEL ERCAN