Geri Dön

Koklear implant kullanıcılarında spektral çözünürlük ile konuşma, uzaysal algı ve işitme kalitesinin değerlendirilmesi

Evaluation of spectral resolution and speech, spatial perception and hearing quality in cochlear implant users

  1. Tez No: 872391
  2. Yazar: SEVDA ÜSTÜNDAĞ
  3. Danışmanlar: DOÇ. DR. BETÜL ÇİÇEK ÇINAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Odyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Spektral çözünürlük becerisi fonksiyonel işitmenin pek çok yönüyle ilişkilidir ve bu beceri, koklear implant (Kİ) kullanıcılarında çeşitli faktörlerden kötü etkilenmektedir. Bu çalışmanın amacı, unilateral Kİ kullanıcıları ve bilateral normal işitmeye sahip olan bireylerin, Spektral – Temporal Modüle Dalgalanma Testi (SMDT) ile değerlendirilen spektral çözünürlük becerileri ile Konuşma, Uzaysal Algı ve İşitme Kalitesi (KUİK) Ölçeğinin 'Konuşma Algısı (KA)', 'Uzaysal Algı (UA)' ve 'İşitme Kalitesi (İK)' alt boyutları ve genel skorunu değerlendirmek ve objektif ve subjektif test sonuçları arasındaki ilişkiyi ortaya koymaktır. Çalışma grubuna en az 1 yıldır unilateral Kİ kullanan, kontrol grubuna ise bilateral normal işitmeye sahip 18-45 yaş aralığında toplam 40 birey katılmıştır. Gruplar arasında cinsiyet (p>0.05) ve yaş (p>0.05) bakımından anlamlı bir farklılık bulunmamaktadır. Çalışma ve kontrol grubundan elde edilen SMDT skoru ve KUİK ölçeğinin KA, UA, İK alt ölçekleri ve genel skorunda gruplar arasında istatistiksel olarak anlamlı bir fark olduğu (p<0.05) ve kontrol grubundan elde edilen skorların daha iyi olduğu bulunmuştur. Korelasyonel analize bakıldığında ise çalışma grubunun SMDT skoru ile KA (r=0.474, p<0.05), İK (r=0.576, p<0.05) ve genel skoru arasında (r=0.463, p<0.05) istatistiksel olarak anlamlı, pozitif ve orta düzey bir ilişki bulunurken UA skoru ile arasında (r=0.267, p>0.05) anlamlı bir ilişki bulunamamıştır. Kontrol grubunun SMDT skoru ile KA (r=0.539, p<0.05) ve İK skoru arasında (r=0.490, p<0.05) istatistiksel olarak anlamlı, pozitif yönlü ve orta düzey bir ilişki, UA (r=0.813, p<0.05) ve genel skoru arasında (r=0.819, p<0.05) ise istatistiksel olarak anlamlı, pozitif ve güçlü bir ilişki bulunmuştur. Sonuç olarak aşağıdan yukarıya girdi kalitesinin bir göstergesi olan spektral çözünürlük ile çalışma grubunun UA skoru dışında, KUİK ölçeğinin KA, UA, İK alt ölçekleri ve genel skoru arasında ilişki bulunmuştur.

Özet (Çeviri)

Spectral resolution ability is associated with many aspects of functional hearing and is adversely affected by various factors in cochlear implant (CI) users. The aim of this study was to evaluate the spectral resolution skills assessed by the Spectral – Temporally Modulated Ripple Test (SMRT) and the 'Speech Perception (SP)', 'Spatial Hearing (SH)' and 'Hearing Quality (HQ)' subscales of the Speech, Spatial and Qualities of Hearing Scale (SSQ) Scale and the overall score of unilateral CI users and individuals with bilateral normal hearing and to reveal the relationship between objective and subjective test results. A total of 40 individuals between the ages of 18-45 years who had been using unilateral CI for at least 1 year and had bilateral normal hearing participated in the study group. There is no significant difference between the groups in terms of gender (p>0.05) and age (p>0.05). It was found that there was a statistically significant difference (p<0.05) between the groups in the SMRT score obtained from the study and control groups and in the SP, SH, HQ subscales and general score of the SSQ scale and that the scores obtained from the control group were better. When correlational analysis was analyzed, a statistically significant, positive and moderate relationship was found between the SMRT score of the study group and SP (r=0.474, p<0.05), HQ (r=0.576, p<0.05) and general score (r=0.463, p<0.05), while no significant relationship was found with the SH score (r=0.267, p>0.05). A statistically significant, positive and moderate relationship was found between the SMRT score of the control group and the SP (r=0.539, p<0.05) and HQ scores (r=0.490, p<0.05), and a statistically significant, positive and strong relationship was found between the SH (r=0.813, p<0.05) and overall scores (r=0.819, p<0.05). As a result, a correlation was found between spectral resolution, which is an indicator of bottom-up input quality, and the SP, SH, HQ subscales and the overall score of the SSQ scale, except for the SH score of the study group.

Benzer Tezler

  1. Koklear implant kullanıcısı yetişkinlerde bellek işlevlerinin değerlendirilmesi ve spektral çözünürlük ile ilişkisinin incelenmesi

    Evaluation of memory functions in adult cochlear implant users and investigation of their relationship with spectral resolution

    SAFİYE SENA NALBANT

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Kulak Burun ve Boğazİstanbul Aydın Üniversitesi

    Odyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ŞENGÜL TERLEMEZ

  2. Koklear implant kullanıcılarında postoperatif intrakoklear elektrokokleografi bulgularının incelenmesi

    Evaluation of postoperative intracochlear electrocochleography results in cochlear implant recipients

    MERVE BAYRİ ULUKAN

    Doktora

    Türkçe

    Türkçe

    2023

    Kulak Burun ve BoğazMarmara Üniversitesi

    Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı

    PROF. DR. AYŞE AYÇA ÇİPRUT

  3. Yetişkin koklear implant kullanıcılarında gürültüde konuşmayı ayırt etme becerisinin spektral çözünürlük, zamansal çözünürlük ve melodik kontur tanıma becerileri ile ilişkisinin değerlendirilmesi

    Assessment of the relationship between speech discrimination in noise abilities and spectral resolution, temporal resolution and melodic contour identification abilities in adult cochlear implant users

    TÜRKAN ÖZLEM BAYÜLGEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET YARALI

  4. Koklear implant kullanıcılarında elektrot nöron arayüzeyinin spektral çözünürlük ve konuşma anlaşılırlığına etkisinin değerlendirilmesi

    Evaluation of the effect of electrode neuron interface on spectral resolution and speech intelligibility in cochlear implant users

    MERVE ÖZSES

    Doktora

    Türkçe

    Türkçe

    2024

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji Ana Bilim Dalı

    DOÇ. DR. BETÜL ÇİÇEK ÇINAR

  5. Koklear implant kullanan bireylerde spektral ve temporal çözünürlük becerilerinin araştırılması

    Investigation of spectral and temporal resolution skills in individuals using cochlear implants

    CANSU TOSYALI SALMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji Ana Bilim Dalı

    DOÇ. DR. MERVE BATUK