İmplant üstü monolitik zirkonya restorasyonların kalınlığının sonuç rengi üzerindeki etkisinin incelenmesi
Examining the effect of the thickness of implant-supported monolithic zirconia restorations on the result color
- Tez No: 868598
- Danışmanlar: DOÇ. DR. KAAN YERLİYURT
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantlar, Dental protez-implant destekli, Dental implants, Dental prosthesis-implant supported
- Yıl: 2024
- Dil: Türkçe
- Üniversite: Tokat Gaziosmanpaşa Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çalışmamızın amacı; implant üstü monolitik zirkonyum (MZ) tasarımlarda üstyapının farklı kalınlık ve doygunluklarda olmasının sonuç renge etkisini değerlendirmektir. Çalışmamızda süper translüsenside A1 ve A2 renklerinde MZ bloklar (VITA YZ ST Multicolor Super Translucent Zirconia,Bad Säckingen, Germany) kullanıldı. 3 boyutlu yazıcı (ELEGOO Saturn 3 Ultra 12K MSLA 3D Yazıcı, Shenzhen, China) ile tasarlanan ve vhf K5 freze makinesi (Ammerbuch, Almanya) ile 1 mm, 1.5 mm, 2 mm kalınlığında A1 ve A2 renklerinde veneer örnekler elde edildi (n=10). Kolorimetre cihazı ile veneerlerin L0*, a0*, b0* değerleri; dayanak ile birlikte veneerlerin L1*, a1*, b1* değerlerleri ölçüldü. Renk farklılıkları; (∆E00*) hesaplandı. 2-yönlü ANOVA ve Eşleştirilmiş Örneklem T-Test ile istatistikleri yapıldı (P˂0.05). Kalınlıklara göre kıyaslandığında L*, a*, b* ve ∆E00* değerleri arasında anlamlı farklılıklar tespit edildi (P<0.05). Tüm gruplarda titanyum altyapı ile birlikte L*, a*, b* değerlerinde anlamlı azalma görüldü. Ölçümler Titanyum altyapı ile yapıldığında üstyapının artık daha koyu, daha yeşil ve daha mavi olduğu ölçüldü. Doygunluklara göre kıyaslandığında A1 ve A2 grupları arasında L* değerinde anlamlı bir faklılık bulunamadı. a* değerinde tüm gruplarda anlamlı bir farklılık bulundu (P˂0.05). b* değerinde ise 1 mm ve 1.5 mm kalınlıklarda anlamlı farklılıklar bulundu (P˂0.05). 2 mm kalınlıkta anlamlı bir fark bulunamadı. ∆E00* değerinde ise tüm gruplar için doygunluk farkının sonuç renge etkisinde anlamlı bir sonuç bulunamadı. Sonuç rengin kalınlık ile doğru orantılı şekilde etkilendiği sonucu ortaya çıkmıştır. Kalınlığın artması ile sonuç renk asıl istenilen renge yaklaşmıştır. Ancak doygunluğun değişmesi her ne kadar a* ve b* değerlerine etki etse de istenilen sonuç renge ulaşmada anlamlı bir sonuç vermemiştir.
Özet (Çeviri)
Our study's objective was to assess how various superstructure thicknesses and saturations affected the final color of implant-supported monolithic zirconium (MZ) designs. In our study, super translucent MZ blocks (VITA YZ ST Multicolor Super Translucent Zirconia, Bad Säckingen, Germany) in A1 and A2 colors were used. Samples were designed with a 3D printer (ELEGOO Saturn 3 Ultra 12K MSLA 3D Printer, Shenzhen, China) and 1 mm, 1.5 mm, 2 mm thick samples in A1 and A2 colors were obtained with a vhf K5 milling machine (Ammerbuch, Germany) (n = 10). L0*, a0*, b0* values of veneers with colorimeter device; L1*, a1*, b1*values of the veneers along with the abutments were measured. Color differences; (∆E00*) was calculated. Statistics were performed by 2-way ANOVA and Paired Sample T-Test (P˂0.001). When compared according to thickness, significant differences were detected between L*, a*, b* and ∆E00* values (P<0.001). A decrease in L*, a*, b* values was observed in all groups with titanium infrastructure. It was measured that with the installation of the titanium substructure, the superstructure was now darker, greener and bluer. The L* value between the A1 and A2 groups did not significantly differ when evaluated using saturations. All groups' a* values showed a significant difference (P<0.001). There were notable variations in the b* value between the thicknesses of 1 mm and 1.5 mm (P˂0.001). No significant difference was found at 2 mm thickness. At ∆E00* value, no significant result was found in the effect of saturation difference on the result color for all groups. The result shows that the color is affected directly proportional to the thickness. As the thickness increased, the result color approached the actual desired color. However, although changing the saturation affected the a* and b* values, it did not give a significant result in achieving the desired color.
Benzer Tezler
- CAD-CAM materyalleri ile üretilen implant üstü restorasyonların farklı siman aralıklarındaki stres dağılımlarının karşılaştırılması
Comparison of stress distributions in different cement thicknesses of implant- retained fixed restorations produced with current CAD-CAM materials
RAZİYE YILDIZ
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. AYŞE GÖZDE TÜRK
- Bruksizmi olan hastalarda implant üstü sabit protezler için farklı implant çapı, sayısı ve üst yapı kalınlıkları varyasyonlarının implant ve çevre dokularında oluşturduğu stres dağılımının sonlu elemanlar stres analizi yöntemiyle değerlendirilmesi
In vitro evaluation of implant and peri-implant tissues different implant diameter, number and upper structure thickness variations for implant supported fixed prosthes regarding distribution by finite elemantal analysis method in patients with bruxism
YAKUP KANTACİ
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiDicle ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. SABİHA ZELAL ÜLKÜ
- İmplant üstü monolitik zirkonya restorasyonlarında farklı açılı abutment ve farklı siman türlerinin kırılma dayanımına etkisi
Effect of different abutment angulations and luting agents on the fracture resistance of implant-supported monolithic zirconia restorations
ÖZGE YILDIZ
Diş Hekimliği Uzmanlık
Türkçe
2026
Diş HekimliğiAnkara Yıldırım Beyazıt ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. MAHMUT SERTAÇ ÖZDOĞAN
- İmplant üstü simante edilen monolitik zirkonya ve metal destekli porselen kronlarda vida erişim deliği açılmasının kron direncine etkisi
Effect of screw access hole on fracture strength of implant supported cement-retained monolithic zirconia and metal supported porcelain crowns
ZEYNEP İLAYDA KONUKÇU KURNAZ
Diş Hekimliği Uzmanlık
Türkçe
2023
Diş HekimliğiAnkara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SEMİH BERKSUN
- Farklı sinterleme parametrelerinin ti-basedayanak üstü monolitik zirkonya restorasyonların kırılma dayanımlarına etkisinin incelenmesi
Effect of different sintering parameters on the fracture strenght of ti-base supported monolithic zirconia restorations
MUSTAFA KAANALP ERGÜL
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiGaziantep ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. FATİH SARI