Geri Dön

Çeşitli kök kanalı dolgu materyallerinin sitotoksik etkileri

Cytotoxic effects of different root canal filling materials

  1. Tez No: 86423
  2. Yazar: HANDAN ODABAŞI
  3. Danışmanlar: PROF. DR. SELMİN AŞÇI
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Endodonti, Kök kanal dolgu materyalleri, Sitotoksisite, Endodontics, Root canal filling materials, Cytotoxicity
  7. Yıl: 1999
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada dört farklı kök kanalı dolgu materyalinin (“Ketac- Endo”,“AH-26”,“Endomethasone”,“Sealapex”) L-Straın hücre kültürleri üzerinde oluşturdukları sitotoksik etkilerin değerlendirilmesi amaçlanmıştır. Hücrelerin sitotoksitesinin belirlenmesinde, Miliporlu filtre ve 3H-Timidin(TdR) otoradyografi olmak üzere iki farklı yöntem kullamlmıştır. Aseptik koşullarda; üretici firmaların önerileri doğrultusunda hazırlanan materyaller; 5 mm. çapında, 4 mm. kalınlığındaki polietilen halkalar içerisine yerleştirilmiştir. Materyaller, taze karıştırılmasını takiben ve 24 saat, 48 saat, 7 gün (168 saat) 37 °CMe %100 nemli ortamda bekletildikten sonra incelenmiştir. Bunu takiben, materyaller 0.2 mm.'lik porlu membran üzerine yerleştirilerek hücrelere uygulanmıştır. Daha sonra, petri kuyucukları 24 saat süreyle inkübe edilmiştir. înkübasyon süresi sonunda; toplam hücre sayısı ve hücre canlılık oram belirlenmiştir. Hücrelerde oluşan DNA sentezi devamlılığını belirleyebilmek amacıyla 3H-TdR otoradyografi yöntemi kullamlmıştır. 124Çalışmadan elde edilen bulgulara göre; * Taze karıştırılmış materyallerin uygulandıkları gruplarda tüm materyaller sitotoksik etki oluşturmuştur. * Taze karıştırılmış materyallerin sitotoksik etkilerinin; materyallerin bekletilme süreleri ile azaldığı belirlenmiştir. * Materyallerin her bir zaman aralığındaki sitotoksik etkileri; birbirlerine kıyasla istatistiksel olarak farklılık göstermiştir (p<0.05). Sadece,“AH-26”ve“Endomethasone”un hücre canlılık oranlan incelemesinde 24 ve 48 saatlik değerler istatistiksel olarak anlamlı bıılunamamıştır (p>0.05). * Tüm materyaller içerisinde, taze karıştırılmış materyallerin bulunduğu gruplarda en az sitotoksik etkiyi“Ketac-Endo”nun gösterdiği belirlenmiştir. Bunu azalan miktarlarda“AH-26”ve“Endomethasone”takip etmiştir. En sitotoksik materyal olarak“Sealapex”belirlenmiştir. Materyallerin bekletilme süreleri ile elde edilen sitotoksik etkilerin azalarak devam ettiği gözlenmiştir. * Her iki yöntemden elde edilen bulguların uyum göstererek, birbirlerini destekledikleri belirlenmiştir. Bu sonucun; çalışmanın güvenilirliğim arttırdığı görüşündeyiz. 125

Özet (Çeviri)

Q NUMMARY- The purpose of this study was evaluate the cytotoxycity of foıır root canal sealers (“Ketac-Endo”,“AH-26”,“Endomethasone”,“Sealapex”) on L-Strain cell cultures. The cytotoxycity was determined with two different methods as milipore filter and 3H-Thymidine (3H-TdR) autoradiography. Under aseptic conditions; the sealers were prepared according to the manufacturer's directions, after than placed into polyethylen rings (5 mm. diameter, 4 mm. length). The materials were evaluated as freshly mixed and after sett for 24 h, 48 h, 7 days (168 h) at 37 °C and % 100 humidity. Then, materials placed onto 0.2 mm. pore sizes membran filter. After then, petri dishes incubated for 24 hour in the incubator. After incubation; total cell count and cell viability were determined. For evaluation of DNA synthesis of cells were used 3H-TdR autoradiography method. In this study, the results showed that; * Freshly prepared materials found more cytotoxic than others.* Cytotoxic effects of materials showed that decrease due to setting time. * All time periods, cytotoxic effects of materials showed that statistically different. But“AH-26”and“Endomethasone”in the cellviability test, 24h and 48h time periods showed no significant difference statistically. * Freshly applied“Ketac-Endo”showed minimal cytotoxic effects to other materials. In this grup“Sealapex”found more cytotoxic. * In this study, similar values obtained with different evaluation methods. This fact showed that the results of this study was reliable. 127

Benzer Tezler

  1. İntrakoronal ağartma işlemlerinin in vitro ve in vivo olarak değerlendirilmesi

    Başlık çevirisi yok

    UMUT TUNGA

    Doktora

    Türkçe

    Türkçe

    1998

    Diş HekimliğiAnkara Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    DOÇ. DR. BADE SONAT

  2. Çeşitli endodontik materyallerin kemik içi implantasyonu ile biyokompatibilitelerinin ve doku yanıtlarının histopatolojik olarak araştırılması

    Histopatological evaluation of the biocompatibility and tissue response reactions of various endodontic materials by intraosseous implantation in rats

    MUZAFFER EMİR DİNÇOL

    Doktora

    Türkçe

    Türkçe

    2001

    Diş Hekimliğiİstanbul Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF.DR. RAİF ERİŞEN

  3. An Investigation of mechanical behavior of teeth by using various dental materials

    Çeşitli diş malzemelerinin mekanik davranışlarının incelenmesi

    MUSTAFA TOPARLI

    Doktora

    İngilizce

    İngilizce

    1996

    Makine MühendisliğiDokuz Eylül Üniversitesi

    PROF.DR. TEVFİK AKSOY

  4. Kök kanallarında oluşan“smear tabakası”nın temizlenmesinin histolojik olarak incelenmesi

    Başlık çevirisi yok

    FARUK HAZNEDAROĞLU

    Doktora

    Türkçe

    Türkçe

    1991

    Diş Hekimliğiİstanbul Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF.DR. ŞÜKRÜ ŞİRİN