Geri Dön

Saçılan ışınlara etki eden faktörlerin Monte Carlo yöntemi ile incelenmesi

Investigation of the factors effecting the scattered radiations by the Monte Carlo method

  1. Tez No: 83441
  2. Yazar: MİNE BAHÇECİ
  3. Danışmanlar: DOÇ. DR. DOĞAN BOR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Monte Carlo, saçılmış radyasyon, saçılma kesri, birikim faktörü, Monte Carlo Yöntemi, Saçılma, Monte Carlo, scattered radiations, scatter fraction, build-up factor 11, Monte Carlo Method, Scattering
  7. Yıl: 1999
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Yüksek Lisans Tezi SAÇILAN IŞINLARA ETKİ EDEN FAKTÖRLERİN MONTE CARLO YÖNTEMİ ile İNCELENMESİ Mine BAHÇECİ Ankara Üniversitesi Fen Bilimleri Enstitüsü Fizik Mühendisliği Anabilim Dalı Danışman : Doç. Dr. Doğan BOR Jüri Üyeleri : Prof. Dr. Sedat IŞDX Doç. Dr. Doğan BOR Doç. Dr. Haluk MUTLU Tanısal radyoloji uygulamalarında görüntü kalitesini etkileyen en önemli parametrelerden bir tanesi saçılan ışınlardır. Bu ışınların miktarı X-ışını enerjisine ve tetkik edilen ortamın fiziksel özelliklerine göre değişiklik gösterir. Bu tezde farklı enerjideki X-ışınlarının değişik materyallerdeki etkileşmelerinin benzeşimi Monte Carlo Tekniği kullanılarak gerçekleştirilmiştir. Dedektöre ulaşan saçılan ışınların miktarına bu değişkenlerin etkisi incelenmiş ve genel bir analitik ifade türetilmiştir. 1999, 83 sayfa

Özet (Çeviri)

ABSTRACT Master Thesis INVESTIGATION of the FACTORS EFFECTING the SCATTERED RADIATIONS by the MONTE CARLO METHOD Mine BAHÇECİ Ankara University Graduate School of Natural and Aplied Sciences Department of Engineering Physics Supervisor : Assoc. Prof. Dr. Doğan BOR Jury : Prof. Dr. Sedat IŞIK Assoc. Prof. Dr. Doğan BOR Assoc. Prof. Dr. Haluk MUTLU One of the most important parameter which degrades the image quality in Diagnostic Radiology applications is the presence of scattered radiation. The amount of scatter shows considerable variotion with the energy of the X-rays and as well as with the physical composition of the medium under investigation. In this thesis, interaction of X- rays with different materials in simulated using Monte Carlo Technique. The effect of these variables to the amount of scattered radiation reaching to the dedector is investigated and analitical expression was derived. 1999, 83 pages

Benzer Tezler

  1. Investigation of mottung in radiography of directionally solidified ni-based alloy gas turbine blades

    Yönlü katılaşmış Ni-bazlı gaz türbin kanatçıklarının radyografisinde mottlingin incelenmesi

    HACER AYGÜN

    Doktora

    İngilizce

    İngilizce

    1996

    Metalurji MühendisliğiOrta Doğu Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. EKREM SELÇUK

  2. Gamma transmisyon yöntemiyle görüntülemede ışınlama geometrisinin görüntü kalitesine etkisi

    Başlık çevirisi yok

    NERMİN KÜÇER (AKŞENER)

    Yüksek Lisans

    Türkçe

    Türkçe

    1992

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. ALİ GİRGİN

  3. Anizotrop dielektrik bir tabakadan düzlemsel elektromagnetik dalgaların saçılması

    Başlık çevirisi yok

    ARSLAN YAZICI

    Yüksek Lisans

    Türkçe

    Türkçe

    1990

    Elektrik ve Elektronik MühendisliğiÇukurova Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. A. HAMİT SERBEST