Su fantomu kullanılarak Co-60 radyoizotop kaynağı ile dış ışınlama şartları için farklı vücut bölgelerine ilişkin doz tayini
Dose determination for different body parts at Co-60 irradiation by using water phantom
- Tez No: 83087
- Danışmanlar: PROF. DR. A. BERİL TUĞRUL
- Tez Türü: Yüksek Lisans
- Konular: Nükleer Mühendislik, Nuclear Engineering
- Anahtar Kelimeler: Kobalt, Radyasyon, Radyoizotoplar, Radyometri, Su fantomu, Cobalt, Radiation, Radioisotopes, Radiometry, Water phantom
- Yıl: 1999
- Dil: Türkçe
- Üniversite: İstanbul Teknik Üniversitesi
- Enstitü: Nükleer Bilimler Enstitüsü
- Ana Bilim Dalı: Nükleer Mühendislik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
SU FANTOMÜ KULLANILARAK Co-60 RADYOİZOTOP KAYNAĞI İLE DIŞ IŞINLAMA ŞARTLARI İÇİN FARKLI VÜCUT BÖLGELERİNE İLİŞKİN DOZ TAYİNİ ÖZET Radyoizotopların farklı alanlarda kullanılmaya başlanması ile birlikte, radyolojik güvenlik ve dozimetri önem kazanmıştır. Burada üzerinde durulması gereken husus; iyonizan radyasyonların çevre, radyasyon çalışanları ve hastaya olabilecek etkileridir. Bu amaçla, özellikle deneysel çalışmaların yapılması gerekmektedir. însan üzerinde deney yapmanın zorluğu nedeni ile çoğu kez, insan eşdeğeri bir malzeme ile, bir başka deyişle, fantom ile çalışma tercih edilmektedir. Su fantomu ise literatürde benzer çalışmalar için önerilen yaygın kullanımlı bir fantom çeşididir. Biçimsel yönden ise, fantomlar çoğu kez, silindirik veya kübik olarak seçilmektedir. Bu çalışmada; farklı su fantomlan kullanılarak radyasyon çalışanları ve nükleer tıp uygulamaları için farklı vücut bölgelerinin, dış ışınlama şartlarında maruz kalabileceği dozların tayini hedeflenmiştir. Farklı vücut bölgesi olarak, baş, boyun, gövde, kol, uyluk ve baldır seçilmiştir. Radyasyon kaynağı olarak, gama aktif Co-60 radyoizotop kaynağı seçilmiştir. Böylelikle, radyasyon çahşanlannca ve nükleer tıp uygulamalarında sıkça kullanılan, yüksek enerjili bir gama radyoizotop kaynakla çalışılmıştır. Dış ışınlama şartları, farklı şekillerde oluşturulmuştur. Bu dış ışınlama şartları oluşturulurken radyasyonla çalışma sırasında karşılaşılabilecek durumlar göz önüne alınarak farklı ışınlama geometrileri oluşturulmuştur. Böylelikle, 5 farklı geometride deneysel çalışmalar gerçeklenmiştir. Deneysel sonuçlar grafik olarak verilmiş, birbirleriyle mukayeseli olarak da değerlendirilmiştir. Ayrıca, teorik hesaplama yöntemi ile de doz hesaplaması yoluna gidilmiş ve bulunan sonuçlar, deneysel sonuçlarla mukayeseli olarak değerlendirilmiştir. Böylelikle, radyasyon çalışanları ve nükleer tıp uygulamaları için önem arzeden bir konuda deneysel çalışmalar yapılmış ve elde edilen sonuçların birbiri ile uyumluluğu gösterilmiştir. Bir başka deyişle, nükleer uygulamalarda sıkça kullanılan bir gama radyoizotop kaynağı olan Co-60 radyoizotopu için farklı dış ışınlama şartlarında deneysel çalışmalar gerçeklenebilmiştir. X111
Özet (Çeviri)
DOSE DETERMINATION FOR DIFFERENT BODY PARTS AT Co-60 IRRADIATION BY USING WATER PHANTOM SUMMARY Radiological safety and dosimetry put forward by using radioisotopes in the different topics. Hence, harmful effects of the ionised radiation on environment, radiation workers and patients. For this purpose, experimental studies must be observed. It is preferred that using a phantom due to hard to study on a man experimentally. Water phantom is a widespread phantom that is suggested for the similar experimental studies in the literatures. Phantoms are used cylindrical or cubic form frequently. In this study, search for dose levels for the different body sections of radiation workers and patients, by using water phantoms. Head, neck, body, arm, thigh and calf of the leg are selected as body sections. Co-60 gamma radioisotope is selected as a radiation source. So, a widespread and high energy gamma source is used for the nuclear applications. External irradiation conditions are designed in different positions according to the realistic cases. Therefore, the experiments are observed in 5 different geometry. Experimental results are given in graphics and evaluated comparatively. Moreover, the theoretical calculation has been done and compared with the experimental results. Therefore, experimental studies which are important for the radiation workers and nuclear medicine, have been done and shown that there are the harmonise of the results. So, it can be realised for the different external irradiation for the Co-60 gamma radioisotope source that is used in nuclear applications frequently. XIV
Benzer Tezler
- Ortogonal radyasyon alanları içeren baş-boyun tümörlerinin, asimetrik kolime edilmiş CO-60 ve 4MV (X) ışınları ile tedavisinde set-up hatalarının birleşim bölgesine etkisi
The Effect of set-up mistakes at the adjacent field junctions in the treatment of head and neck tumors with orthogonal radiation fields at C=-60 which collimated asymmetrically 4 MV X-ray beams
HALİL KÜÇÜCÜK
Yüksek Lisans
Türkçe
1999
Onkolojiİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
DOÇ. DR. HATİCE BİLGE
- Gamma Knife'ın fiziksel ve dozimetrik parametrelerinin incelenmesi
Assessing physical and dosimeteric parameters of Gamma Knife
ZEYNEP ÖZEN İŞBAKAN
Yüksek Lisans
Türkçe
1999
Biyofizikİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
DOÇ. DR. HATİCE BİLGE
- 6 MeV, 8 Mev, 10 MeV, 12 MeV elektron demetlerinde farklı SSD'lerde (kaynak yüzey mesafesi) standart kon içine yerleştirilen cutoutların (alan şekillendiricileri) yüzde derin doz ve verime olan etkileri
The Effects of various size cutouts, placed in standard electron cone, at different SSD (source skin distance) and various electron beam (6 MeV, 8 MeV, 10 MeV, 12 MeV) levels on percentage depth dose and outputs
BÜLENT YAPICI
Yüksek Lisans
Türkçe
2001
Radyoloji ve Nükleer TıpHacettepe ÜniversitesiRadyasyon Fiziği Uygulamaları Ana Bilim Dalı
DOÇ. DR. MURAT GÜRKAYNAK
- Monte Carlo hesaplarının saçılma kesri ve doz ölçümlerine uygulanması
Application of Monte Carlo calculations to the scatter fraction and dose measurement
NİYAZİ MERİÇ
Doktora
Türkçe
1996
Fizik ve Fizik MühendisliğiAnkara ÜniversitesiFizik Ana Bilim Dalı
PROF.DR. NURAY BÜGET
- Mültilif kolimatör ve serrobent bloklarla oluşturulan düzensiz alanların verim faktörleri, kolimatör saçılma faktörleri ve fantom saçılma faktörlerinin ölçümü ve karşılaştırılması
Measurement and comparison of output factors, collimator scatter factors and phantom scatter factors of irregular fields shaped with cerrobend blocks and multileaf collimator
AYDAN GÜRSES
Yüksek Lisans
Türkçe
1999
OnkolojiHacettepe ÜniversitesiRadyasyon Fiziği Uygulamaları Ana Bilim Dalı
PROF. DR. İ. LALE ATAHAN