Geri Dön

Kısa implantlar ve kapalı sinüs tabanı kaldırma tekniği ile uygulanan standart implantların primer stabilitelerinin in-vitro olarak karşılaştırılması

In-vitro comparison of primary stability of short implants and standard implants applied with closed sinus augmentation technique

  1. Tez No: 828237
  2. Yazar: EMRAH GENCELİ
  3. Danışmanlar: DOÇ. DR. EMİNE ÇİFCİBAŞI
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: kısa implant, kapalı sinüs yükseltme, primer stabilite, periotest, Osstell, Cerrahi-diş hekimliği, Dental implantasyon, Dental implantlar, Maksiller sinüs, short implants, closed sinus augmentation, primary stability, periotest, Osstell, Dentistry-operative, Dental implantation, Dental implants, Maxillary sinus
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Periodontoloji Ana Bilim Dalı
  12. Bilim Dalı: Periodontoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu tez çalışması, kapalı sinüs tabanı yükseltme işlemi sonrası yerleştirilecek olan 8 mm'lik implantlar ile sinüs tabanı yükseltilmeden yerleştirilmesi önerilen 5 mm'lik kısa implantların arasındaki primer stabilite farklılığının rezonans frekans analizi (Osstell) ve periotest yöntemi ile karşılaştırılarak incelenmesini amaçlamaktadır. Gereç ve yöntem: Çalışmada kemik modeller için taze sığırdan elde edilmiş kaburga kemikleri 6 mm kalınlığında önce separe ile daha sonra hassas kesme cihazı ile standart olacak şekilde hazırlandı. 5 mm uzunlunluğundaki kısa implantlar (Mode® İmplant, İstanbul, Türkiye) firmanın önerilerine uygun şekilde kemiklere yerleştirildi. 8 mm uzunluğundaki standart implantlar (Mode® İmplant, İstanbul, Türkiye) ise osteotomi yöntemi ile kemiklere yerleştirildi. Örneklem sayısı toplamda n=40 olarak hesaplandı. İmplantların yerleştirilmesini takiben iki grup için de Periotest (Gulden-Medizintechnik, Bensheim, Almanya) ve Osstell (Integration DiagnosticAB, Goteborg, İsviçre) cihazları ile primer stabilite ölçümleri yapıldı. Elde edilen veriler SPSS 22.0 programı kullanılarak Shapiro-Wilk testi ile normallik dağılımına bakıldıktan sonra Student t testi ile karşılaştırmalı analizleri yapıldı. Anlamlılık düzeyi p<0,05 olarak seçildi. Bulgular: Çalışmada kısa implantların ortalama primer stabilitesi Periotest ölçümlerinde ortalaması -4,0250+134198 ve ISQ ortalaması frontalden 75,65+2,03974, lateralden 73,07+2,12303 olarak bulunmuştur. Standart boydaki implantlar ile kısa implantlar arasında primer stabilite açısından anlamlı farklılık bulunamamıştır. Sonuç: Kısa implantların azalmış kemik yüksekliği olan arka bölgelerde kullanımı normal uzunluktaki implantlarla benzer şekilde primer stabiliteye sahiptir.

Özet (Çeviri)

Aim: The aim of this thesis study is to investigate the difference in primary stability between 8 mm implants placed after closed sinus lifting surgery and 5 mm short implants recommended for placement without sinus lifting, by comparing the resonance frequency analysis and Periotest methods. Materials and methods: For the bone models in the study, costa obtained from fresh cattle were prepared at a standard thickness of 6 mm, first with a separator and then with a precision cutting device. Short implants with a length of 5 mm (Mode® İmplant, İstanbul, Türkiye) were placed into the bones according to the manufacturer's recommendations. Standard 8 mm long implants (Mode® İmplant, İstanbul, Türkiye) were placed into the bones using the osteotomy method. The total sample size was calculated as n=40. After implant placement, primary stability measurements were made for both groups using Periotest (Gulden-Medizintechnik, Bensheim, Germany) and Osstell (Integration DiagnosticAB, Goteborg, Switzerland) devices. The data obtained were analyzed using SPSS 22.0 software, and after checking the normality distribution with the Shapire-Wilk test, comparative analyses were performed with the Student t-test. The significance level was set at p<0.05. Results: In the study, the average primary stability of short implants was found to be -4.0250+134198 in Periotest measurements, and the average ISQ was 75.65+2.03974 from the frontal region and 73.07+2.12303 from the lateral region. There was no significant difference in terms of primary stability between standard-sized implants and short implants. Conclusion: Short implants have similar primary stability to regular-length implants when used in posterior regions with reduced bone height.

Benzer Tezler

  1. Atrofik maksillanin rehabilitasyonunda farklı implant konfigürasyonlarının ve farklı kemik yoğunluklarının etkilerinin sonlu elemanlar analizi ile incelenmesi

    Evaluation of different implant configuration and bone density effects in atrophic maxilla by finite element analysis

    ZEYNEP GÜMRÜKÇÜ

    Doktora

    Türkçe

    Türkçe

    2016

    Diş HekimliğiKaradeniz Teknik Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    YRD. DOÇ. DR. YAVUZ TOLGA KORKMAZ

  2. Transkateter aort kapak implantasyonu (tavi) yapılan ve başarılı bir şekilde taburcu edilen hastalarda hastane dışı mortalite üzerine etkili olabilecek faktörlerin değerlendirilmesi

    Assessment of the factors affecti̇ng out-of-hospi̇tal mortali̇ty i̇n pati̇ents who underwent transcatheter aorti̇c valve i̇mplantati̇on (tavi) procedure and were successfully di̇scharged

    SIDDIK ERDOĞAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    KardiyolojiSağlık Bilimleri Üniversitesi

    Kardiyoloji Ana Bilim Dalı

    PROF. DR. CEM BARÇIN

  3. İskeletsel ankraj yönteminde maksiller protraksiyon ve alt-ramec uygulamasının etkinliğinin incelenmesi

    Evaluation of the effects of bone-anchored maxillary protraction with or without alt-ramec in the peak pubertal period

    BERNA ERTEKİN

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiSüleyman Demirel Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. ELÇİN ESENLİK

  4. Sol ventrikül destek cihazı implantasyonu yapılan hastalarda karotis ve orta serebral arterlerdeki akım dalgalarının analizi ve nörokognitif fonksiyonlara etkisi

    The analysis of carotid and middle cerebral arterial flow waveform in patients implanted of left ventricular assist device and its effects on neurocognitive functions

    MEHMET KARAHAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2017

    Göğüs Kalp ve Damar CerrahisiSağlık Bilimleri Üniversitesi

    Kalp ve Damar Cerrahisi Ana Bilim Dalı

    DR. SİNAN SABİT KOCABEYOĞLU

  5. Elastik intramedüller çivi ile tedavi edilen çocuk ön kol çift kemik kıırklarının klinik ve radyolojik sonuçları

    Clinical and radiological results of pediatric diapyseal both bone forearm fractures treated with elastic intramedullary nailing

    İDRİS DEMİRTAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Ortopedi ve TravmatolojiMersin Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. MEHMET ÇOLAK