Geri Dön

Enterkonnekte Şebekede Adaptif Rezerv Yönetiminin Otomatik Üretim Kontrolü Üzerine Etkisi

Impacts of Adaptive Reserve Management on Automatic Generation Control for Interconnected Power Grid

  1. Tez No: 821376
  2. Yazar: ALİ GÜLEÇ
  3. Danışmanlar: PROF. DR. MÜSLÜM CENGİZ TAPLAMACIOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Adaptif model izleme kontrol sistem, Elektrik güç sistemleri, Adaptive model following control system, Electric power systems
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Elektrik Elektronik Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Elektrik enerjisini yüksek kapasitelerde depolamanın uygun ve verimli bir çözümü bulunmadığı için elektriksel güç üretildiği anda tüketilmelidir. Bu nedenle bir elektrik şebekesinde üretim ve tüketim her zaman denge içinde olmalıdır. Şebekedeki yüklerin çeşitliliği ve dinamik olmasından kaynaklı tüketim talebi anlık ve dinamik olarak sürekli değişmektedir. Bu nedenle üretiminde dinamik bir şekilde tüketime eşit olacak şekilde değişmesi gerekmektedir. Üretim ve tüketim arasındaki denge bozulduğu zaman sistem frekansı nominal değerinden sapmaya başlamaktadır. Bu sapmayı en kısa süre içerisinde üretimi artırarak veya azaltarak gidermek Otomatik Üretim Kontrolünün (AGC) temel görevidir. Bu çalışma kapsamında, adaptif rezerv yönetimi metodolojisinin Otomatik Üretim Kontrolü (AGC) üzerindeki etkileri, IEEE dokuz baralı ana şebeke ve bu şebekeye bağlı harici bir şebekede üzerinden incelemiştir. Yenilikçi adaptif rezerv kontrol metodu sayesinde acil durum koşullarında güvenlik odaklı kontrol algoritması devreye girerek tüm sekonder rezervleri aynı anda devreye alıp ACE değerini mümkün olan en kısa süre içerisinde sıfıra indirmeye çalışırken; normal durum koşullarında market odaklı kontrol algoritması çalışarak piyasa koşullarına en uygun santralden başlamak üzere sekonder rezervleri sırasıyla devreye almaktadır. Yapılan simülasyon çalışmaları, güvenlik odaklı rezerv kontrol algoritmasının market odaklı kontrol algoritmasına göre; ACE değerini sıfıra indirerek sistem frekansını nominal değerine getirme performasının zamansal olarak iki kat daha hızlı olduğunu göstermektedir. Böylece, adaptif rezerv yönetim metodolojisinin AGC performansını artırdığı yapılan çalışmalar sayesinde gözlemlenmiştir.

Özet (Çeviri)

Since there is no suitable and efficient solution for storing electrical energy in high capacities, electrical power must be consumed as soon as it is generated. For this reason, production and consumption in an electricity network should always be in balance. The consumption demand due to the variety and dynamics of the loads in the network is constantly changing instantaneously and dynamically. For this reason, it is necessary to change its production dynamically in such a way as to be equal to consumption. When the balance between production and consumption decays, the system frequency begins to deviate from its nominal value. It is the main task of Automatic Genaration Control (AGC) to eliminate this deviation by increasing or decreasing production in the shortest possible time. Within the scope of this study, the effects of adaptive reserve management methodology on AGC were examined by IEEE on a nine-bus main network and an external network connected to this network. Thanks to the innovative adaptive reserve control method, a safety-oriented control algorithm is activated in emergency conditions, activating all secondarm reserves at the same time and trying to reduce the ACE value to zero as soon as possible; under normal conditions, the market-oriented control algorithm works and activates the secondarm reserves respectively, starting from the power plant that is most suitable for market conditions. Simulation studies conducted show that the performance of the security-oriented reserve control algorithm to bring the system frequency to its nominal value by reducing the ACE value to zero is twice as fast temporally compared to the market-oriented control algorithm. Thus, it has been observed through studies that adaptive reserve management methodology improves AGC performance.

Benzer Tezler

  1. Development of an adaptive and flexible automatic generation control scheme for power system splitting

    Güç sistemi ayrışması için uyarlanabilir ve esnek bir otomatik üretim kontrol yapısının geliştirilmesi

    ARMAĞAN TEMİZ

    Doktora

    İngilizce

    İngilizce

    2025

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. MURAT GÖL

  2. Yerel elektrik santrallerinin kontrolu

    Non-utility generation control

    İSTEMİHAN GENÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ÖMER USTA

  3. Yenilenebilir enerji sistemleri ile entegre iki alanlı güç sisteminde yük frekans kontrolü için optimizasyon yöntemleri kıyaslaması

    Comparison of optimization methods for load frequency control in a two-area power system integrated with renewable energy systems

    FATİH DEMİRCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    PROF. DR. AYŞEN DEMİRÖREN

  4. Enterkonnekte şebekede bulanık mantık algoritma ile çok alanlı otomatik üretim kontrolu

    Multi-area automatic generation control by fuzzy logic controllers in interconnected network

    HAKAN SARAÇOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2007

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    PROF.DR. AYŞEN DEMİRÖREN

  5. Güneş enerji sistemli iki bölgeli enterkonnekte şebekede modern kontrol teknikleri ile yük-frekans kontrolü

    Load-frequency control with modern control techniques in two-area interconnected grid with solar energy system

    GÖKSU GÖREL

    Doktora

    Türkçe

    Türkçe

    2017

    Elektrik ve Elektronik MühendisliğiKırıkkale Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ERTUĞRUL ÇAM