Farklı materyallerden üretilen tarama gövdelerine uygulanan sterilizasyon ve torklama işlemlerinin dijital ölçü sonuçlarına etkisinin araştırılması
The accuracy of digital impressions: the effect of implant SCAN-BODY material, sterilization procedure and repeated torque tightening
- Tez No: 810594
- Danışmanlar: PROF. DR. HAKAN DEMİR
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dijital ölçü tekniği, tarama gövdesi, titanyum, PEEK, POM-C, tork, sterilizasyon, Dijital tarama, Polietereterketon, Sayısal tarayıcılar, Ölçüm teknikleri, Ölçümleme, Digital impression technique, scan body, titanium, PEEK, POM-C, torque, sterilization, Digital scanning, Polyetheretherketone, Digital scanners, Measurement techniques, Measurement
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Sivas Cumhuriyet Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın amacı dijital ölçü doğruluğu üzerine etkili olan tarama gövdelerinin üretildiği materyallerin, tekrarlayan kullanımda torklama ve sterilizasyon prosedürleri sonrasında ölçü doğruluğuna etkisini araştırmaktır. Çalışmada titanyum, PEEK ve POM-C'den üretilen tarama gövdeleri kullanılmış ve 3 farklı sterilizasyon prosedürüne tabi tutulmuştur. Bunlar otoklav sterilizasyonu (134°C'de 2.2 atm basınç altında 3 dk süreyle), düşük sıcaklıkta kuru hava sterilizasyonu (150°C'de 2,5 saat süreyle) ve yüksek sıcaklıkta (170°C'de 1 saat süreyle) kuru hava sterilizasyonudur. Tarama gövdeleri başlangıç aşamasında, 5 tork ve sterilizasyon döngüsünden sonra, 10 tork ve sterilizasyon döngüsünden sonra laboratuvar tipi tarayıcıyla taranmış ve STL dosyası olarak kaydedilmiştir. Başlangıç aşamasındaki tarama referans ölçüm olarak kabul edilmiş ve bilgisayar ortamında sonraki ölçümlerle çakıştırılmış, aradaki farklılık x, y ve z eksenlerinde sayısal değer olarak (mikrometre cinsinden) kaydedilmiş, elde edilen veriler istatistiksel olarak değerlendirilmiştir. Çalışmadan elde ettiğimiz bulgulara göre; hem 5 kez torklama ve otoklav sterilizasyonu, hem de 10 kez torklama ve otoklav sterilizasyonu prosedürlerini takiben yapılan ölçüm sonuçlarına göre titanyum ve PEEK güvenilir bulunurken, POM-C tarama gövdeleri z ekseninde yani vertikal yönde güvenli sonuç vermemektedir. 5 kez torklama ve düşük sıcaklıkta sterilizasyon prosedürünü takiben yapılan ölçüm sonuçlarına göre tüm tarama gövdeleri kullanıma uygundur. 10 kez torklama ve düşük sıcaklıkta sterilizasyon prosedürünü takiben yapılan ölçüm sonuçlarına göre; titanyum ve PEEK güvenilir bulunurken, POM-C tarama gövdeleri z ekseninde yani vertikal yönde güvenli sonuç vermemektedir. Hem 5 kez torklama ve yüksek sıcaklıkta kuru hava sterilizasyonu hem de 10 kez torklama ve yüksek sıcaklıkta kuru hava sterilizasyonu prosedürünü takiben yapılan ölçüm sonuçlarına göre, kullanıma uygun tek materyal titanyumdur. POM-C tarama gövdeleri yüksek sıcaklıkta eridiği için kullanıma uygun değildir. PEEK tarama gövdeleri z ekseninde güvenli sonuç vermemektedir. Titanyum tarama gövdeleri tüm materyaller arasında en doğru sonuçları vermiştir. Herhangi bir sterilizasyon prosedürü uygulanarak 10 kez kullanımı güvenlidir. PEEK tarama gövdeleri otoklav sterilizasyonunda ve düşük sıcaklıkta kuru hava sterilizasyonu yöntemleriyle 10 kez steril edilip yeniden kullanıma uygunken, yüksek sıcaklıkta kuru hava sterilizasyonuyla steril edilip yeniden kullanılması uygun değildir. Bu yöntemle steril edilecekse, sadece bir kez kullanılması önerilebilir. Tarama gövdesi materyalleri arasında yeni bir materyal olan POM-C tarama gövdesi ise tekrarlayan kullanım düşünülüyorsa, düşük sıcaklıkta kuru hava sterilizasyon yöntemiyle steril edilip tekrar kullanılabilir.
Özet (Çeviri)
The aim of this study was to evaluate the effect of the scan body material, torque, and sterilization procedures in repeated use on the accuracy of digital implant impressions. In this study, scan bodies produced from titanium, PEEK, and POM-C were used and subjected to 3 different sterilization procedures. These were autoclave sterilization (at 134°C for 3 minutes at 2.2 atm pressure), low-temperature dry air sterilization (at 150°C for 2.5 hours), and high temperature (170°C for 1 hour) dry air sterilization. Scan bodies were scanned at the initial stage, after 5 torque and sterilization cycles, and after 10 torque and sterilization cycles with a laboratory scanner and saved as an STL file. The scan at the initial stage was accepted as a reference measurement and overlapped with subsequent measurements digitally, and the difference was recorded as micrometers on the x, y, and z axes. The data obtained from this study were evaluated statistically with the SPSS 22.0 program. According to the findings obtained from the study; following both 5 times torque and autoclave sterilization and 10 times torque and autoclave sterilization procedures, titanium, and PEEK are found to be reliable and accurate, while POM-C scan bodies did not give accurate results in the z-axis, that is, in the vertical direction. All scan bodies were suitable for reuse, according to the measurement results following the 5 times torque and low-temperature sterilization procedure. According to the measurement results following the 10 times torque and low-temperature sterilization procedure; while titanium and PEEK are found to be reliable, POM-C scan bodies did not give reliable results in the z-axis, that is, in the vertical direction. According to the measurement results following both 5 times torque and high- temperature dry air sterilization and 10 times torque and high-temperature dry air sterilization procedure, the only suitable material for use was found titanium. POM-C scan bodies were not suitable for use because they melt at high temperatures. PEEK scan bodies did not give reliable results on the z-axis. The most accurate scan body was found to be titanium, regardless of the sterilization method and the number of torques. While PEEK scan bodies were found suitable for reuse after being sterilized 10 times with autoclave sterilization and lowtemperature dry air sterilization methods, they were not suitable for sterilization and reuse by high-temperature dry air sterilization. If it is to be sterilized by this method, it can be considered to discard after one use. The POM-C scan body, which is a new material among the scan body materials, can be sterilized and reused 5 times with lowtemperature dry air sterilization if repetitive use is considered. If other sterilization methods are to be used, it may be considered to using them only once and discard.
Benzer Tezler
- Yeni jenerasyon restoratif materyaller kullanılarak bilgisayar yardımıyla tasarlanan ve üretilen kron restorasyonların, 3 boyutlu görüntü hizalama yöntemiyle klinik aşınma miktarlarının incelenmesi
Examining clinically surface wear amount of crown restorations produced by CAD&CAM method using new jeneration restorative material with 3 dimensional image aligning
DİDEM OĞUZ
Diş Hekimliği Uzmanlık
Türkçe
2017
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. AKIN ALADAĞ
- Preslenebilir zirkonya ile güçlendirilmiş lithium silikat kuronların marjinal uyum ve kırılma dayanımının İn Vitro karşılaştırılması
In Vitro comparison of marginal fit and fracture strengt of pressable zirconia reinforced lithium silicate crowns
FULYA GÜLENER
Doktora
Türkçe
2024
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. DEĞER ÖNGÜL
- Dijital ve geleneksel ölçü teknikleri ile elde edilen protetik restorasyonların internal ve marjinal uyumlarının değerlendirilmesi
Evaluation of internal and marginal adaptations of prosthetic restorations with digital and conventional impression techniques
SAFA ÖZDEN
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiSivas Cumhuriyet ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. HAKAN DEMİR
- Evcil pratikler: Seksenli yıllarda ev imgesi ve mekansal izdüşümler
Domestic practices: Spatial projections of the home image in 1980s
BÜŞRA KARA
- Monolitik CAD/CAM materyallerinin yapay yaşlandırma sonrası aşınma ve kırılma dayanımlarının araştırılması
Investigation of wear and fracture resistance of monolithic CAD/CAM ceramic materials after artificial aging
ASLIHAN KUTLUK
Doktora
Türkçe
2023
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. DEĞER ÖNGÜL