Geri Dön

Yoğun bakım ünitesinde intrakraniyal patoloji nedeniyle eksternal ventriküler drenaj kateteri takılan hastalarda BOS drenajının optik sinir kılıf çapına etkisinin değerlendirilmesi

Başlık çevirisi mevcut değil.

  1. Tez No: 797217
  2. Yazar: GÜLŞAH ORAK
  3. Danışmanlar: PROF. DR. YUSUF TUNALI
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
  6. Anahtar Kelimeler: Artmış kafa içi basıncı, optik sinir kılıf çapı, ultrasonografi, noninvaziv, eksternal ventriküler drenaj, Drenaj, Optik sinir, Serebral ventriküller, Serebrospinal sıvı, Yoğun bakım, Yoğun bakım üniteleri, İntrakraniyal basınç, Increased intracranial pressure, optic nerve sheath diameter, ultrasonography, noninvasive, external ventricular drainage, Drainage, Optic nerve, Cerebral ventricles, Cerebrospinal fluid, Intensive care, Intensive care units, Intracranial pressure
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi-Cerrahpaşa
  10. Enstitü: Cerrahpaşa Tıp Fakültesi
  11. Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Kafa içi basıncı (KİB) artmış hastaların tedavisinde uzun dönem nörolojik sonuçları iyileştirmek için yüksek KİB'in belirlenmesi gereklidir. Ultrasonografik optik sinir kılıfı çapı (OSKÇ) ölçümü, yüksek KİB'i saptamak için noninvaziv, kolay uygulanan ve uygun maliyetli bir tekniktir. Bu çalışmanın amacı, OSKÇ ile direkt KİB ölçümleri arasındaki korelasyonu değerlendirmek ve KİB≥15 mmHg'yi saptamak için OSKÇ eşik değerini belirlemektir. Gereç ve Yöntem: Prospektif, tek merkezli ve tek uygulayıcıyla yapılan bu çalışmada yoğun bakım ünitesine kabul edilen, KİB yüksekliği nedeniyle eksternal ventriküler drenaj kateteri takılan ve göz patolojisi olmayan 14 yaş üstü 44 hasta değerlendirildi. BOS (beyin omurilik sıvısı) drenajından önce ve sonra KİB ve OSKÇ ölçülerek değişiklikler ve korelasyonları araştırıldı. Bulgular: BOS drenajı öncesi ve sonrası KİB ve OSKÇ ölçümleri arasında istatistiksel olarak anlamlı bir ilişki bulundu (p<0.001). BOS drenajı ile KİB ve OSKÇ'de istatistiksel olarak anlamlı azalma bulundu (p<0.001). Ayrıca bu azalma serebral perfüzyon basıncındaki artışla ilişkilidir (p<0.001). ROC eğrisi altındaki alan 0,701 idi (%95 [CI] = 0,530 ila 0,872). KİB≥15 mmHg olduğunda OSKÇ eşik değeri 5,35 mm olarak belirlendi (Sensitivite %53, spesifite %86, Youden index 0,395). Sonuç: Bu çalışmada OSKÇ ve KİB korelasyonu literatür ile benzer bulunmuştur. Ayrıca KİB 15 mmHg'nin üzerinde olduğunda OSKÇ eşik değeri 5,35 mm olarak belirledik.

Özet (Çeviri)

Aim: Determination of high ICP is necessary for the treatment of patients with raised ICP to improve long-term neurological outcomes. Ultrasonographic optic nerve sheath diameter (ONSD) measurement is a noninvasive, easily performed and cost effective technique for detecting high ICP. However, ICP measurements via ventricular catheters provide CSF drainage and ICP reduction. The normal ICP value is less than 15 mmHg in adults. In the literature the correlation of ONSD and invasive ICP measurements were determined. The aim of present study is to evaluate the correlation of ONSD and direct ICP measurements and to determine cut off ONSD value to detect ICP ≥15 mmHg. Materials and Methods: In this prospective, single-center and single operator study, 44 patients older than 14 years of age, who were admitted to the ICU, had an external ventricular drainage catheter due to raised ICP, and had no eye pathology, were included. ICP and ONSD were measured before and after CSF drainage than changes and their correlations were investigated. Results: A statistically significant correlation was found between ICP and ONSD measurements before and after CSF drainage (p<0.001). A statistically significant decrease was found in ICP and ONSD with CSF drainage (p<0.001). Additionally, this reduction is associated with an increase in cerebral perfusion pressure (p<0.001). The area under the ROC curve was 0.701 (95% [CI] = 0.530 to 0.872). The ONSD cut-off value was determined as 5,35 mm when ICP≥15 mmHg (Sensitivity of 53%, specificity of 86%, Youden index of 0,395). Conclusion: In the present study, the ONSD and ICP correlation was found similar to the literature. We also determined the cut-off ONSD value as 5.35 mm when ICP more than 15 mmHg.

Benzer Tezler

  1. Perkütan Dilatasyonel Trakeostomi'nin intrakraniyal basınç üzerine olan etkisinin incelenmesi

    Investigation of the effect of Percutaneous Dilatation Tracheostomy on intracranial pressure

    MERYEM SEDEF DEMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Anestezi ve ReanimasyonAkdeniz Üniversitesi

    Anestezi ve Reanimasyon Ana Bilim Dalı

    PROF. MURAT YILMAZ

  2. Yenidoğan konvülziyonlu hastaların klinik ve elektrofizyolojik bulgularının retrospektif olarak değerlendirilmesi

    Retrospective evaluation of newborn sei̇zures wi̇th cli̇ni̇cal and electrophysi̇ologi̇cal si̇gns

    MUSTAFA ALPER AYKANAT

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    Çocuk Sağlığı ve HastalıklarıOndokuz Mayıs Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    DOÇ. DR. HAMİT ÖZYÜREK

  3. Çocuk yoğun bakım ünitesinde travma nedeniyle ı̇zlenen hastaların değerlendirilmesi

    Başlık çevirisi yok

    SÜMEYYE YAVUZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2026

    Çocuk Sağlığı ve HastalıklarıSağlık Bilimleri Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    DOÇ. DR. ZEYNELABİDİN ÖZTÜRK

  4. Beyin ödemi olan hastalarda serum NT-proBNP' nin rolü ve klinik gidiş ile ilişkisinin değerlendirilmesi.

    Evaluation of serum NT-proBNP levels' role in patients with brain edema and the relationship between the clinical course.

    HASAN ÇELİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2011

    Çocuk Sağlığı ve HastalıklarıDicle Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    YRD. DOÇ. DR. MUSTAFA TAŞKESEN