Hareketli ortamlarda kullanılabilen düşük hücre hacimli katı-hal kompozit elektrotların hazırlanması
The preparation of potentiometric composite electrodes with low flow-through cell which can be used in flowing conditions
- Tez No: 78570
- Danışmanlar: YRD. DOÇ. DR. İBRAHİM IŞILDAK
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Katı-Hal Elektrot, Kompozit Elektrot, İyon-Seçici Elektrot, Hareketli Ortam, Dedektörler, Katıhal elektrot, İyon kromatografisi, Solid-state electrode, Composite electrode, Ion-selective electrode, Flowing condition, Detectors, Solid state electrode, Ion chromatography
- Yıl: 1998
- Dil: Türkçe
- Üniversite: Ondokuz Mayıs Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Analitik Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Ill HAREKETLİ ORTAMLARDA KULLANILABİLEN DÜŞÜK HÜCRE HACİMLİ KATI-HAL KOMPOZİT ELEKTROTLARIN HAZIRLANMASI ÖZET İyon kromatografik analizlerde yeni dedektör sistemlerine duyulan ihtiyaç, süregelen ve problemdir. Grafit, epoksi ve bir sertleştiricinin temel teşkil ettiği katı-hal kompozit elektrotlar, iyon kromatografide dedektör olarak kullanılmak amacıyla hareketli ortamlarda test edilmiştir. Hareketli faz olarak su ve çeşitli tuz çözeltileri kullanılmış, yaklaşık 5 fil hücre hacmine sahip anyon ve katyon duyarlı kompozit elektrotların çok düşük konsantrasyonlarda çok sayıda anyon ve katyona karşı cevap sergiledikleri gözlenmiştir. Elektrotlar 5 ay süresince yapılan testlerde kısa cevap zamanı ve yaklaşık Nernst kanununa uygun davranış göstermişlerdir. Hazırlanan kompozit elektrot dedektörler ekonomik ve basit dizaynı ile hareketli ortamlarda kolayca uygulanabilmektedir.
Özet (Çeviri)
IV ABSTRACT The need to develop new detection methods in ion chromatographic systems is a continuing problem. Solid-state composite electrodes based on graphit-epoxy and hardener incorporating active material were tested as dedector for ion chromatography in flowing conditions. Deionized water and different salt solutions were used as mobile phase in flow-through measurements. Composite anion and cation-selective electrode which has almost 5 ul flow-through cell showed response to many anions and cations at low concentrations. In 5 months time, the preprared electrodes exhibited short response time and nearly Nernst behaviour. Composite anion and cation-selective electrodes prepared as detectors are cheap, easy to construct and simple to use in flowing conditions employed in ion chromatographic purposes.
Benzer Tezler
- ATM networks and ATM switching architectures
ATM (Asenkron transfer modu) ağları ve ATM seçici mimarileri
TOLGA AÇIKÖZ
Yüksek Lisans
İngilizce
1998
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik ÜniversitesiKontrol ve Bilgisayar Mühendisliği Ana Bilim Dalı
DOÇ. DR. MEHMET BÜLENT ÖRENCİK
- On the point vortex dynamics
Noktasal girdap dinamiği üzerine
AHMET KUTSİ NİRCAN
Yüksek Lisans
İngilizce
1992
Gemi Mühendisliğiİstanbul Teknik ÜniversitesiYRD. DOÇ. DR. ALİ RANA ATILGAN
- Ejection from rapidly depressurized vessels containing bubbly - liquid two - phase fluid
Gaz kabarcıklı sıvı iki fazlı akışkan tanklarından ani basınç düşüşü yaratarak fışkırma
ŞÜKRÜ BALTA
Yüksek Lisans
İngilizce
1993
Makine Mühendisliğiİstanbul Teknik ÜniversitesiPROF. DR. HASAN FEHMİ YAZICI
- Indexing and browsing of multimedia content data with MPEG-7
Çoğul ortamlar verilerinin MPEG-7 ile indekslenmesi ve taranması
OĞUZ İÇOĞLU
Yüksek Lisans
İngilizce
2001
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik ÜniversitesiPROF. DR. MUHİTTİN GÖKMEN