Çevresel örneklerde eser düzeydeki nikelin katı faz mikroekstraksiyonu ile ayrılması ve zenginleştirilmesi
Separation and enrichment of nickel at trace level in environmental samples by solid phase microextraction
- Tez No: 767683
- Danışmanlar: PROF. DR. MUSTAFA SOYLAK
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Manyetik HP-2MG, zenginleştirme, Ni(II), katı faz mikroekstraksiyon, alevli atomik absorpsiyon spektrometresi, Alevli atomik soğurma spektrometresi, Katı faz özütlemesi, Magnetic HP-2MG, preconcentration, Ni(II), solid phase microextraction, flame atomic absorption spectrometry, Solid phase extraction, Enrichment
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Erciyes Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Nanobilim ve Nanoteknoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmada, eser miktarda Ni(II) 2-(5-Bromo-2-pridilazo)-5-(dietilamino) fenol (Br-PADAP) şelatları halinde hızlı adsorpsiyonu, zenginleştirilmesi ve tayini için manyetik Diaion HP-2MG reçinesi sentezlenmiştir. Ni(II) geri kazanmasını etkileyen parametreler arasında; pH, reçine miktarı, matris etkisi, numune hacmi, eluent tipi ve hacmi optimize edildi ve zenginleştirme işleminden sonra FAAS analizler yapıldı. Gözlenebilme sınırı (LOD), tayin sınırı (LOQ) ve zenginleştirme faktörü sırasıyla 14.7 µg L-1, 49.0 µg L-1 ve 100'dir. Adsorban, adsorpsiyon özelliklerinden herhangi bir kayıp olmadan 15 kez kullanılabildi. Sunulan katı faz mikroekstraksiyon yönteminin doğruluğu, sertifikalı referans malzemelerin analizi ile kontrol edildi. Geliştirilen yöntemin çeşitli gerçek örneklere başarı ile uygulandı.
Özet (Çeviri)
In this study, magnetic Diaion HP-2MG resin was synthesized for rapid adsorption, enrichment and determination of trace amounts of Ni(II) as 2-(5-Bromo-2-pyridylazo)-5-(diethylamino) phenol (Br-PADAP) chelates. Among the parameters affecting on the recoveries of Ni(II); pH, resin amount, matrix effect, sample volume, eluent type and volume were optimized and analyzes were performed by using FAAS after pre-concentration. Limit of detection (LOD), limit of quantification (LOQ) and preconcentration factor was 14.7 µg L-1, 49.0 µg L-1 and 100, respectively. The adsorbent could be used 15 times without any loss its adsorption properties The accuracy of the presented solid phase microextraction procedure was checked by the analysis of certified reference materials. The developed method has been successfully applied to various real samples.
Benzer Tezler
- Çevresel örneklerde bakır (II)'nin doğru ve duyar tayini için yeni bir yaklaşım
A new approach for accurate and sensitive determination of copper (II) in environmental samples
FURKAN UZCAN
- Eser düzeyde bazı analitlerin ayırma ve zenginleştirmesi için yeni yaklaşımlar
NEW approaches to separation and preconcentration for some analytes at trace level
SEDA DUMAN
- Amberlit XAD-7 reçinesi ile metal zenginleştirilmesi ve AAS ile tayinleri
Pre-concentration of heavy metals with triethanolamine immobilised amberlite XAD-7
BAŞAK CANER
- Pet şişelerden içme suyuna geçen antimon miktarının belirlenmesi
Determination of antimony concentration leaching from pet bottles into drinking water
DENİZ ATAKAN
- Sulu örneklerde eser düzeydeki ağır metal iyonlarının alevli atomik absorpsiyon spektrometresi ile tayini için katılaştırılmış yüzen organik damla mikroekstraksiyon tekniği ile önderiştirilmesi
Determination of trace heavy metal ions in aqeous samples by flame atomic absorption spectrometry after preconcentration with solidified floating organic drop microexraction technique
BURCU KAYA DALCI