Geri Dön

Kablolu ve kablosuz endodontik motorların tork değerlerinin karşılaştırılması

Comparison of the torque values of the wired and wireless endodontic motors

  1. Tez No: 767362
  2. Yazar: NURGÜL TEMİZKAN ÇAKAR
  3. Danışmanlar: DR. ÖĞR. ÜYESİ FARUK ÖZTEKİN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Alet Kırılması, Endomotor, Tork, Dental aygıtlar, Dental eğeler, Endodonti, Kök kanal tedavisi, Kırılma, Fracture, Torque Control Motor, Torque, Dental instruments, Dental files, Endodontics, Root canal therapy
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Endodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Teknolojinin ve metalürjinin gelişmesiyle birlikte endodontide de yenilikler olmuştur. Ancak bu yenilikler doğru kullanılmadığında cihaz arızalarına ve alet kırılmalarına sebep olmaktadır. Bu çalışmada, endodontik motorlaron tork değerlerini torkmetre ile ölçerek karşılaştırmayı amaçladık. VDW Resiproc Gold, Dentsply Xsmart kablolu, VDW Connect, Dentsply IQ Smart endomotorları kullanıldı. Kanal eğesi olarak Scope Uni Gold serisinin F1 eğesi kullanıldı. Kanal eğesi 18 mm de endomotora sabitlendi. Endomotorlar daki en düşük hızda otoreverse hareketi yapana kadar rotasyon hareketi yaptırıldı. Tork metre de ki başlangıç değeri ve otoreverse hareketi yaptığı anda ki değerler kaydedildi. Bu işlemler 10 defa tekrarlandı. İstatiksel analiz olarak kategori sayısı iki ise ilişkisiz örneklemler Mann Whitney U testi, kategori sayısı ikiden fazla ise Kruskall Wallis testi kullanıldı. Dizayn ettiğimiz laboratuar şartları altında VDW Connect drive 1Ncm, 2Ncm, 3Ncm gruplarında VDW Resiproc kabloluya göre daha fazla tork üretmiştir. Dentsply kablolu endomotor, kablosuz endomotora göre 1Ncm, 2Ncm, 3Ncm gruplarında daha fazla tork üretti. Dentsply ve VDW kablosuz endomotorların da 1Ncm, 2Ncm, 3Ncm arasında anlamlı farklılıklar gözlenmedi. Bu durumun endomotorların üretim şekillerinden kaynaklı olabileceğini düşünmekteyiz. Dönme miline bir sensörün sinyal iletimini ve güç kaynağı cihazını takmak zor olduğu için işlemin teknik hassasiyeti yüksektir. Klinisyenler endomotorun herhangi tork değerinde çalışırken kayıtlı torka güvenmemeli ve her zaman operasyonel torku artıracak uygulamalardan kaçınmalıdırlar.

Özet (Çeviri)

With the development of technology and metallurgy, there have been innovations in endodontics. However, when these innovations are not used correctly, they cause device malfunctions and tool breakages. In this study, we aimed to compare different torque increases of endomotors by measuring them with a torquemeter. VDW Resiproc Gold, Dentsply Xsmart Plus, VDW Connect, Dentsply IQ Smart endomotors were used. F1 file of Scope ni golGd series was used as canal file. The canal file was fixed to the endomotor at 18 mm. Rotation movement was performed until the autoreverse movement was performed at the lowest speed in the endomotors. The initial value in the torque meter and the values at the moment of autoreverse movement were recorded. These processes were repeated 10 times. For statistical analysis, if the number of categories were two, the unrelated samples Mann Whitney U test was used, and if the number of categories were more than two, the Kruskall Wallis test was used. There are significant differences between all groups under the laboratory conditions we designed. VDW Connect drive produced more torque in 1Ncm, 2Ncm, 3Ncm groups than VDW Resiproc cable. Dentsply wired endomotor is more in 1Ncm, 2Ncm, 3Ncm groups than wireless endomotor. We think that this situation may be caused by the brand. The technical precision of the operation is high, as it is difficult to install the signal transmission of a sensor and the power supply device on the rotation shaft. Clinicians should not rely on recorded torque when operating at any torque value of the endomotor and should always avoid practices that increase operational torque.

Benzer Tezler

  1. Kablolu televizyon (Gelişimi teknolojisi ekonomisi)

    Başlık çevirisi yok

    ÜNLEN DEMİRALP

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Radyo-TelevizyonAnadolu Üniversitesi
  2. Japon gazeteciliği

    Başlık çevirisi yok

    MURAT YEŞİL

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Gazetecilikİstanbul Üniversitesi

    DOÇ. DR. MEHMET NİYAZİ ÖKTEM

  3. Vişne hasadında mekanizasyon olanakları üzerinde bir araştırma

    A Research on the mechanical harvestability of sour cherries

    SELİM ÇETİNKAYA

    Doktora

    Türkçe

    Türkçe

    1989

    ZiraatAnkara Üniversitesi

    Tarımsal Mekanizasyon Ana Bilim Dalı

    PROF. DR. DOĞAN ERDOĞAN

  4. Avrupa Topluluğu'nda radyo-televizyon sistemleri

    Başlık çevirisi yok

    ALİ İHSAN ÖZEROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1990

    İletişim Bilimleriİstanbul Üniversitesi

    Avrupa Birliği Ana Bilim Dalı

    DR. ŞERMİN TEKİNALP