Üst solunum yolu enfeksiyonu nedeni ile intranazal topikal dekonjestan kullanımı sonrası ön segment değişimlerinin değerlendirilmesi
Evaluation of anterior segment changes after intranasal topical decongestant use for upper respiratory tract infection
- Tez No: 765675
- Danışmanlar: PROF. DR. HÜLYA GÜNGEL, DR. PINAR SULTAN
- Tez Türü: Tıpta Uzmanlık
- Konular: Göz Hastalıkları, Eye Diseases
- Anahtar Kelimeler: Korneal Tomografi, Oksimetazolin, Ön segment Parametreleri, Göz hastalıkları, Kornea, Korneal hastalıklar, Solunum sistemi, Solunum yolları enfeksiyonları, Tomografi, Ön kamara, Corneal Tomography, Oxymetazoline, Anterior Segment Parameters, Eye diseases, Cornea, Corneal diseases, Respiratory system, Respiratory tract infections, Tomography, Anterior chamber
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Sağlık Bilimleri Üniversitesi
- Enstitü: İstanbul Eğitim ve Araştırma Hastanesi
- Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
AMAÇ: Üst solunum yolu enfeksiyonunda intranazal dekonjestan olarak kullanılan Oksimetazolin (İLİADİN® Merck %0,05 Dozajlı Sprey)'in göz açısından sağlıklı gönüllülerde ön segment parametrelerinde ve göz içi basıncında oluşturabileceği etkileri; yaş, cinsiyet, aksiyel uzunluk gibi verilerle korelasyonunu incelemektir. GEREÇ VE YÖNTEM: Sağlık Billimleri Üniversitesi İstanbul Eğitim ve Araştırma Hastanesi Kulak Burun Boğaz Polikliniği'ne üst solunum yolu enfeksiyonu nedeni ile başvuran semptomatik ve terapötik amaçlı ilaç reçetesi verilen ancak ilaç kullanmaya henüz başlamamış, prospektif çalışma için gönüllü 50 hasta İstanbul Eğitim ve Araştırma Hastanesi Göz Polikliniği'ne yönlendirilmiştir. ÜSYE' den başka sistemik herhangi bir hastalığı olmayan, oftalmolojik olarak sağlıklı 50 gönüllü hastanın 100 gözünün dahil edildiği çalışmada, intranazal yoldan kullanılan oksimetazolin içerikli dekonjestanın (İLİADİN® Merck %0,05 Dozajlı Sprey) etkilerini değerlendirmeyi amaçladık. İlacın kullanılmadan önceki bazal, farmakokinetik ve farmakodinamik özellikleri göz önünde bulundurularak etkisinin belirgin olabileceği 10. dakika ve etkilerinin geriye dönebileceğinin düşünüldüğü 1.saatteki ölçümler alındı. Kombine Scheimpflug-Placido disk tabanlı tomografi cihazı (CSO Florence, İtalya) ile ön segment ölçümleri ve non kontakt tonometre (Topcon CT-80 non kontakt tonometre, Japonya) cihazı ile göz içi basıncı(GİB) ölçümü yapıldı. Sirius Kornea Tomografi cihazından elde edilen; İridokorneal açı (İKA), Ön Kamara Derinliği (ÖKD), Ön Kamara Hacmi (ÖKH), Skotopik Pupil Çapı (SPÇ), Mezopik Pupil Çapı (MPÇ), Fotopik Pupil Çapı (FPÇ), Dinamik Pupil Çapı (DPÇ), Total Yüksek Sıralı Aberasyonlar (HOA), Non İnvaziv Gözyaşı Kırılma Zamanı (Nİ-GKZ), Kristalin Lens Yüksekliği (KLY) verileri ile göz içi basınç(GİB) değişimleri değerlendirildi. BULGULAR: 50 gönüllü hastanın 100 gözünün dahil edildiği çalışmada olguların 27'si Kadın, 23'ü Erkekti. 10.dakikada ve 1.saatteki İKA ve KLY değerinin bazal döneme göre (p<0.05) azaldığı 1.saatte ise 10.dakikaya göre anlamlı (p < 0.05) artış gösterdiği saptandı. ÖKD, ÖKH, PÇ (skotopik, mezopik, fotopik) değerinin ilaç uygulama öncesine göre 10. dakika ve 1. saatte anlamlı (p<0.05) artış gösterdiği, 1.saatte ise 10.dakikaya göre anlamlı (p < 0.05) azaldığı saptandı. Nİ-GKZ değerinin 10. dakika ve 1. saatteki değeri bazal döneme göre anlamlı (p<0.05) düşüş gösterse de 1.saatte 10.dakikaya göre anlamlı (p > 0.05) değişim göstermediği saptanmıştır. Yaş ile bazal, 10.dakika ve 1.saatteki İKA, ÖKD, ÖKH değeri arasında anlamlı (p < 0.05) negatif korelasyon, KLY ile pozitif korelasyon gözlenmiştir. Aksiyel Uzunluk ile bazal, 10.dakika ve 1.saatteki İKA, ÖKD ve ÖKH değeri arasında anlamlı (p < 0.05) pozitif korelasyon gözlenmiştir. Erkeklerde aksiyel uzunluk kadınlardan anlamlı (p < 0.05) olarak daha yüksek saptanmıştır. Bunun yanında kadın ve erkekler arasında GİB, İKA, ÖKH, PÇ (skotopik, mezopik, fotopik, dinamik), HOA, Nİ-GKZ ve KLY değerlerinde bazal döneme göre 10.dakika ile 1.saatte ayrıca 1.saatte 10.dakikaya göre istatistiksel olarak anlamlı (p > 0.05) farklılık izlenmemiştir. Dinamik PÇ ve HOA değişimlerinde tüm zaman dilimlerinde anlamlı olarak fark saptanmamıştır.(p>0,05) SONUÇ: Oksimetazolin içerikli nazal dekonjestanların kullanılması ile erken dönemde ön segment parametrelerinde değişimler tespit edilmiştir. Ancak göz içi basıncı ve yüksek sıralı aberasyonlarda değişim izlenmemiştir. Ön segment parametrelerinden İKA'da daralma, ÖKD ve ÖKH 'de artma, PÇ'de genişleme ve KLY'de azalma gözlendi. Sık kullanılan oksimetazolin içerikli dekonjestanların göz bulgularının akılda tutulması tedavi öncesi önem taşmaktadır.
Özet (Çeviri)
AIM: To investigate the effects of oxymetazoline (ILIADIN®, Merck 0.05% Dosage Spray), an intranasal decongestant used to treat upper respiratory tract infections, on anterior segment parameters and intraocular pressure in healthy volunteers, as well as the correlation with data such as age, gender, and axial length. MATERIALS AND METHODS: 50 patients applied to Health Sciences University Istanbul Training and Research Hospital Ear, Nose, and Throat Polyclinic with an upper respiratory tract infection (URTI) and were prescribed symptomatic and therapeutic drugs but had not yet started using the drugs and voluntered for prospective study were directed to the Istanbul Training and Research Hospital Eye Polyclinic. We aimed to evaluate effects of an intranasally used oxymetazoline-containing decongestant (ILIADIN®, Merck, 0.05% Dosage Spray) in this study which included 100 eyes of 50 ophthalmologically healthy volunteer patients without any systemic disease other than URTI. Measurements was taken at the 10th minute, when the effect may be evident, and at the 1st hour, where the effects are thought to be reversible, from all patients considering that the basal, pharmacokinetic, and pharmacodynamic proporties of the drug. Anterior segment measurements were made with a combined Scheimpflug-Placido disc-based tomography device (CSO Florence, Italy) and intraocular pressure (IOP) was measured with a non-contact tonometer (Topcon CT-80 non-contact tonometer, Japan). Iridocorneal angle (ICA), anterior chamber depth (ACD), anterior chamber volume (ACD), scotopic pupillary diameter (SPD), mesopic pupillary diameter (MPD), photopic pupillary diameter (FPD), dynamic pupillary diameter (DPD), and total high intraocular pressure changes were evaluated with sequential aberrations (HOA), non-invasive tear break up time (NI-BUT) and crystalline lens rise (CLR) datas were evaluated. RESULTS: In the study, in which 100 eyes of 50 volunteer patients were included, 27 of the cases were female and 23 were male. It was determined that the ICA and CLR values at the 10th minute and 1st hour decreased (p < 0.05) compared to the basal period and increased significantly (p < 0.05) at the 1st hour compared to the10thminute. It was determined that ACD, ACV and PD (scotopic, mesopic, and photopic) values increased significantly (p <0.05) at the 10th minute and 1st hour compared to pre-medication and decreased significantly (p <0.05) at the 1st hour compared to the 10th minute. Although the NI-BUT value decreased significantly (p <0.05) at the 10th minute and at the 1st hour compared to the baseline period, it was not found to change significantly (p > 0.05) at the 1st hour compared to the 10th minute. A significant (p <0.05) negative correlation was observed between age and baseline, 10th minute and 1st hour in ICA, ACD and ACV values, and a positive correlation was observed with CLR. A significant (p < 0.05) positive correlation was observed between Axial Length and baseline, 10th minute and 1st hour in ICA, ACD and ACV values. Axial length was found to be significantly higher (p < 0.05) in men than in women. In addition no significant difference (p > 0.05) was observed, in IOP, ICA, ACD, PD (scotopic, mesopic, photopic, dynamic), HOA, NI-BUT and CLR values between men and women at the 10th minute and 1st hour compared to the basal period and also according to the 10th minute at the 1st hour. There was no significant difference in dynamic PD and HOA changes in all time periods. (p>0.05) CONCLUSİON: Changes in anterior segment parameters were detected in the early period with the use of nasal decongestants containing oxymetazoline. However, no change was observed in intraocular pressure or high-order aberrations. Among the anterior segment parameters, narrowing in ICA, increases in ACD and ACV, enlargement in PD, and a decrease in CLR were observed. It is important to keep in mind the eye findings of frequently used oxymetazoline containing decongestants before treatment.
Benzer Tezler
- Maraş otunun östaki tüp fonksiyonuna etkisi
The effect of Maraş powder on eustachian tube function
AHMET CAN
Tıpta Uzmanlık
Türkçe
2026
Kulak Burun ve BoğazKahramanmaraş Sütçü İmam ÜniversitesiKulak Burun Boğaz Hastalıkları Ana Bilim Dalı
PROF. DR. İSRAFİL ORHAN
- Tavşan modelinde intratonsiller, kısa ve uzun etkili steroid enjeksiyonunun palatin tonsil boyutlarına olan etkisinin karşılaştırılması
Başlık çevirisi yok
SAYNUR ŞİMŞEK
Tıpta Uzmanlık
Türkçe
2025
Kulak Burun ve BoğazSelçuk ÜniversitesiKulak Burun Boğaz ve Baş-Boyun Cerrahisi Ana Bilim Dalı
DOÇ. DR. MERİH ÖNAL
- Alt ve üst solunum yolu enfeksiyonu ile çocuk acile başvuran çocuklarda viral etyoloji sıklığının araştırılması
An investigation on the frequency of viral etiology among the children referred to pediatric emergency service with lower and upper respiratory tract i̇nfection
SUZAN İCİL
Tıpta Uzmanlık
Türkçe
2015
Çocuk Sağlığı ve HastalıklarıÇukurova ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
PROF. DR. HAYRİ LEVENT YILMAZ
- Astımlı çocuklarda viral üst solunum yolu enfeksiyonu tedavisinde pelargonium sidoides etkinliğinin değerlendirilmesi
Assessment of pelargonium sidoides efficiency on viral upper respiratory tract infections in children with asthma
MELİH YAMAN
Tıpta Uzmanlık
Türkçe
2012
Çocuk Sağlığı ve HastalıklarıErciyes ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
PROF. DR. TÜRKAN PATIROĞLU
- Süt çocuğunun geçici hipogammaglobülinemisi olan hastalarda üst solunum yolu enfeksiyonu tedavisinde pelargonium sidoides etkinliğinin değerlendirilmesi
Assessment of pelargonium sidoides efficiency on upper respiratory tract infections in children with transient hypogammaglobulinemia of infancy (thi)
AYDIN TUNÇ
Tıpta Uzmanlık
Türkçe
2010
Allerji ve İmmünolojiErciyes ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
PROF. DR. TÜRKAN PATIROĞLU