Floresan ve nonfloresan glaze ı̇şlemlerinin farklı CAD/CAM Cam seramik materyallerinin renk değişimi üzerine etkisinin ı̇ncelenmesi
Effect of Fluorescent and Nonfluorescent Glaze Processes on Color Change of Different CAD/CAM Glass Ceramic Materials
- Tez No: 765415
- Danışmanlar: PROF. DR. FUNDA BAYINDIR
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: CAD/CAM, cam seramik, floresan, glaze, renk, Dental materyaller, Dental porselen, Diş renk değişikliği, Seramik sırları, CAD/CAM, glass ceramic, glaze, fluorescent, color, Dental materials, Dental porcelain, Tooth discoloration, Fluorescence, Ceramic glazes
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Atatürk Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı farklı yarı saydamlık değerlerine sahip lityum disilikatla güçlendirilmiş ve lösitle güçlendirilmiş CAD/CAM cam seramik materyallerine uygulanan farklı yüzey işlemlerinin renk değişimi üzerine etkisini incelemektir. Materyal ve Metot: Çalışmada her bir gruptan 30 adet olmak üzere toplam 120 adet 2 farklı CAD/CAM (IPS e.max CAD ve IPS Empress CAD) materyalinin 2 farklı yarı saydamlıkta (HT ve LT) blokları kullanılmıştır. Blok halindeki CAD/CAM cam seramik materyalleri 7x7x0,6 mm boyutlarında olacak şekilde su jet cihazı (DWJ1525- FA; Dardi International Corporation, Nanjing, China) kullanılarak kesilmiştir. Her bir grup kendi içerisinde 3 alt gruba ayrılarak farklı yüzey işlemleri (polisaj, floresan ve nonfloresan glaze) uygulanmıştır. Yüzey işlemleri öncesinde ve sonrasında tüm örneklerin renk ölçümü gri bir arka plan üzerinde EasyShade® Advance 4.0 (Vita Zahnfabrik, Bad Sackingen, Germany) cihazı ile yapılarak L*, a*, b* değerleri kaydedilmiş ve CIEDE2000 (Comission Internationale de L'Eclairage) formülü kullanılarak ΔE00 değerleri elde edilmiştir. Elde edilen veriler varyans analizi ile incelenmiş, gruplar arasındaki farklılığın karşılaştırılmasında Post Hoc testleri kullanılmıştır. Ayrıca yüzey işlemleri sonrasında gruplar için ortalama L*, a* ve b* değerleri kaydedilerek her bir grup çifti arası ΔE00 renk farkını hesaplamak için kullanılmıştır. Bulgular: Farklı yüzey işlemleri uygulanan CAD/CAM cam seramik materyalleri için ΔE00 değeri materyal tipi, yarı saydamlık ve yüzey işlemlerinin üçlü interaksiyonlarından etkilenmemektedir (p>0,05). İkili interaksiyonlarda ise materyal tipi-yüzey işlemi etkileşimlerinin önemli (p<0,01); materyal tipi-yarı saydamlık, yüzey işlemi-yarı saydamlık etkileşimlerinin ise istatistiksel olarak önemli olmadığı görülmektedir (p>0,05). Yarı saydamlık, yüzey işlemleri ve materyal tipinin ΔE00 değeri üzerinde etkisinin önemli olduğu görülmüştür (p<0,01). ∆E00 değeri floresan glaze uygulanan grup (ΔE00=1,32) ve nonfloresan glaze uygulanan gruplarda (ΔE00=1,24) polisaj uygulanan grupların ∆E değerinden (ΔE00=0,78) yüksek bulunmuş, en yüksek ∆E değeri IPS e.max CAD HT floresan glaze örnek grubunda (ΔE00=1,49), en düşük ∆E değeri ise IPS Empress CAD LT polisaj örnek grubunda (ΔE00=0,59) saptanmıştır. Sonuç: IPS e.max CAD ve IPS Empress CAD materyallerine uygulanan farklı yüzey işlemleri renk üzerinde etkilidir. ∆E00 sonuçları incelendiğinde polisaj yapılan grupta algılanabilirlik eşiğinin altında renk değişimi gözlenirken, glaze işlemleri sonucunda materyallerde algılanabilirlik eşiğinin üstünde kabul edilebilirlik eşiğinin ise altında renk değişimi meydana geldiği gözlenmiştir. Glaze işlemleri polisaj işlemine göre renk üzerinde anlamlı şekilde daha fazla renk değişimine sebep olmaktadır.
Özet (Çeviri)
Aim: The aim of this study is to examine the color changes of CAD/CAM glass ceramic materials reinforced with lithium disilicate and reinforced with leucite with different translucency values which is applied to different surface treatments. Material and Methods: In the study, 2 different CAD/CAM (IPS e.max CAD and IPS Empress CAD) materials with two different translucency (HT and LT) blocks, 30 sample from each group, for a total of 120 sample, were used. Blocks CAD/CAM glass ceramic materials were cut into 7x7x0.6 mm dimensions using a water jet device (DWJ1525-FA; Dardi International Corporation, Nanjing, China). Each group was divided into 3 subgroups and different surface treatments (polishing, fluorescent and nonfluorescent glaze) were applied. Color measurment of all samples was made before and after applying the surface treatment by using EasyShade® Advance 4.0 (Vita Zahnfabrik, Bad Sackingen, Germany) device on a gray background, L *, a *, b * values were recorded and ∆E00 values were obtained by using the formula CIEDE2000 (Comission Internationale de L'Eclairage). Post Hoc tests were used to compare the differences between the obtained data, analysis of variance and the thinned groups. In addition, after surface treatments, the average L*, a* and b* values were recorded for the groups and used to calculate the ∆E00 color difference between each pair of groups. Results: For CAD/CAM glass ceramic materials with different surface treatments, the ∆E00 value is not affected by material type, light transmittance and the triple interactions of surface treatments. (p>0.05).In bilateral interactions, material typesurface treatment interactions are significant (p<0.01); material type-light transmittance, surface treatment-light transmittance interactions are not statistically significant (p>0.05).The effect of light transmittance, surface treatments and material type on the ∆E00 value was significant (p<0.01).The ∆E00 value of fluorescent glazed group (∆E00=1,32) and non fluorescent glazed group (∆E00=1,24) was found to be higher than the ∆E value of the polished group (∆E00=0,78), The highest ∆E value was found in the IPS e.max CAD HT fluorescent glaze sample group (∆E00=1,49), and the lowest ∆E value was found in the IPS Empress CAD LT polishing sample group (∆E00=0,59). Conclusion: Different surface treatments applied to IPS e.max CAD and IPS Empress CAD materials affect the color change. When the ∆E00 results were examined, a color change was observed below the detectability threshold in the polished group, while a color change occurred above the perceptibility threshold and below the acceptability threshold in the materials as a result of glazing processes. Glaze processes cause significantly more color change than polishing process.
Benzer Tezler
- Random flep modelinde meydana gelen biyokimyasal ve histolojik değişikliklerin indosiyanin yeşili floresan anjiografi değişiklikleri ile karşılaştırılması ve korelasyonu
Comparison and correlation of biochemical and histological changes in the random flap model with indocyanine green fluorescent angiography changes
ERKAN DENİZ
Tıpta Uzmanlık
Türkçe
2022
Plastik ve Rekonstrüktif CerrahiGazi ÜniversitesiPlastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı
PROF. DR. KEMAL FINDIKÇIOĞLU
- Normozoospermik ve non-normozoospermik hasta gruplarında dna fragmentasyon oranının sperm anöploidilerine etkisi
The effect of dna fragmentation rate on sperm aneuploidy in normozoospermic and non-normozoospermic patient groups
AYÇA DEMİREL
Yüksek Lisans
Türkçe
2018
ÜrolojiEskişehir Osmangazi ÜniversitesiTıbbi Genetik Ana Bilim Dalı
PROF. DR. SEVİLHAN ARTAN
- Bina aydınlatmasında kullanılan led ve kompakt floresan lambaların güç kalitesine etkileri
Effects of led and compact fluorescent lights used in building lighting on power qualiyt
TÜLAY BAYRAKDAR
Yüksek Lisans
Türkçe
2023
Elektrik ve Elektronik MühendisliğiSakarya ÜniversitesiElektrik ve Elektronik Mühendisliği Ana Bilim Dalı
PROF. DR. ERTAN YANIKOĞLU
- İnsan sperminde kromozomal anöploidiler ve morfolojik özellikler arasında ilişkilerin morfometrik ve floresan in situ hibridizasyon (FISH) yöntemleriyle araştırılması
Assessment of the relatonship between chromosomal aneuploidies and morphology of human sperm by morphometry and fluorescent in situ hybridization
ÇİLER ÇELİK ÖZENCİ
Doktora
Türkçe
2003
MorfolojiAkdeniz ÜniversitesiHistoloji ve Embriyoloji Ana Bilim Dalı
PROF. DR. RAMAZAN DEMİR
PROF. DR. GABOR HUSZAR
- Melanositik tümörlerde dna kopya sayısı ve kromozomal değişikliklerin floresan ın situ hibridizasyon yöntemi ile değerlendirilmesi, ayırıcı tanı ve prognostik öneminin araştırılması
Evaluation of dna copy number changes and chromosomal aberrations in melanocytic tumors by fluorescence ın-situ hybridization method, ınvestigation of ıts differential diagnosis and prognostic value
DENİZ SOLGUN ANLAR