Geri Dön

Değişen kalınlıklarda Co-Cr dental metal altyapılarda üretim yöntemi, bağlantı ajanı kullanımı ve farklı soğutma protokollerinin seramik bağlantısına etkisi

Effect of manufacturing method, use of bonding agent and different cooling protocols on ceramic bond strength in varying Co-Cr dental alloy thickness

  1. Tez No: 763498
  2. Yazar: EMİNE İKİZ
  3. Danışmanlar: PROF. DR. SİMEL AYYILDIZ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: üretim yöntemi, altyapı kalınlığı, bağlantı direnci, Dental bonding, Dental materyaller, Dental porselen, Dental protezler, Dental stres analizi, Takma diş tabanları, Üretim yöntemleri, production method, core thickness, bond strength, Dental bonding, Dental materials, Dental porcelain, Dental prosthesis, Dental stress analysis, Denture bases, Production methods
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

AMAÇ: Bu çalışmanın amacı; Co-Cr dental metal altyapı materyalinin üretim yöntemi, kalınlığı, seramik uygulaması öncesi bağlantı ajanlarının kullanımı ve soğutma protokollerinin seramik bağlantısına olan etkisinin incelenmesidir. GEREÇ VE YÖNTEM: Çalışmada test grubu için direkt metal lazer sinterleme (DMLS) tekniği kullanılarak 20x5 mm boyutlarında ve 2,3,4 mm değişen kalınlıklarda dikdörtgen Co-Cr altyapılar (n=120) üretildi. Kontrol grubu için döküm tekniği ile 20x5x3 mm boyutlarında örnekler (n=10) üretildi. Her bir örneğin üzerine 8x3x1 mm boyutlarında feldispatik porselen pişirildi. Seramik uygulaması öncesinde örneklerin yarısına bağlantı ajanı uygulandı. Örneklere seramik pişimi sonrasında 2 farklı soğutma protokolü uygulandı. Bağlantı direnci; makaslama bağlantı direnci testi ile ölçüldü. Metal-seramik ara yüzeyi, oksit tabakasının kalınlığını inceleyebilmek ve bağlantı özelliklerini anlayabilmek için optik mikroskop ve taramalı elektron mikroskobu ile görüntülendi. Bağlantı ajanı ve örneklerin elemental içeriği Enerji Dispersiv X-ray spektroskopisi ile belirlendi. BULGULAR: Bağlantı ajanı uygulanan örneklerde koheziv fraktürler gözlemlenirken, metal-seramik bağlantı değerleri ve fraktür çeşitliliği arasında bir korelasyon bulunamamıştır. Bağlantı ajanı ve yavaş soğutma protokolünün uygulanması 2-3 mm kalınlığındaki örneklerde bağlantı değerlerini düşürmüştür, bu durum TiO2 bakımından zengin bağlayıcı ajan ile Co-Cr alaşımın reaksiyona girememesinden kaynaklandığı düşünülmektedir. 4 mm örneklerde bağlantı değerleri arasında farklı gruplarda istatistiksel olarak anlamlı bir fark bulunamamıştır. En yüksek bağlantı değerleri sırasıyla; Co-Cr_L2c (28,58 MPa), Co-Cr_C (25,84 MPa), Co-Cr_L4bc (23,99 MPa)'dır. SONUÇ: Altyapı kalınlığı ile bağlantı direnci değerleri arasında pozitif korelasyon gözlenmiştir; ancak yavaş soğutma protokolü ve Ti-zengin bağlantı ajanı kullanımı metal-seramik bağlantı direncini düşürmüştür.

Özet (Çeviri)

AIM: The aim of this study is to examine the effect of manufacturing technique, thickness, use of bonding agent before ceramic firing and cooling protocols on the ceramic bond of CoCr dental metal substructure. MATERIAL AND METHOD: In the study, rectangular Co-Cr substructures (n=120) with dimensions of 20x5 mm and varying thicknesses of 2,3,4 mm were produced using the direct metal laser sintering (DMLS) technique for the test group. For the control group, 20x5x3 mm samples (n=10) were produced by casting technique. 8x3x1 mm feldspathic porcelain was fired on each sample. Before the ceramic application, the bonding agent was applied to half of the samples. Two different cooling protocols were applied to the samples after ceramic firing. Bond strength was determined by shear bond strength test. The metal-ceramic interface was visualized with an optical microscope and a scanning electron microscope (SEM) to examine the thickness of the oxide layer and to understand the bonding properties. The bonding agent and elemental content of the samples were determined by Energy Dispersive X-ray spectroscopy (EDS). RESULTS: Cohesive fracture occurred in specimens treated with bonding agent but no correlation between fracture types and bond strength values. The application of the bonding agent and slow cooling protocol decreased the average bonding strength in 2 and 3 mm thick samples, attributed to the nonexistent reaction between the TiO2-rich bonding agent and the Co-Cr alloy. The bond strength was not significantly different in 4 mm thick samples. The highest bond strength values Co-Cr_L2c (28,58 MPa), Co-Cr_C (25,84 MPa), Co-Cr_L4bc (23,99 MPa) respectively. CONCLUSION: There was positive correlation between core thickness and bond strength values but slow cooling protocol and application Ti-rich bonding agent decrease the bond strength. The production method did not affect the metal-ceramic bond.

Benzer Tezler

  1. Mikrodalga kalkanlayıcı malzeme tasarım ve analizi

    Design and analysis of microwave shielding materials

    UMUT ŞÜKRÜ YAŞAR

    Doktora

    Türkçe

    Türkçe

    2025

    Elektrik ve Elektronik MühendisliğiKaradeniz Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HAYDAR KAYA

  2. Ultra ince geçiş metal filmlerin (Py/Cr, PtCo) kristallografik yapıları ve magnetik özelliklerinin belirlenmesi

    Characterizing crystallographic structure and magnetic properties of ultra thin metal films Py/Cr, PtCo

    MUSTAFA ERKOVAN

    Doktora

    Türkçe

    Türkçe

    2010

    Fizik ve Fizik MühendisliğiGebze Yüksek Teknoloji Enstitüsü

    Fizik Ana Bilim Dalı

    YRD. DOÇ. DR. OSMAN ÖZTÜRK

  3. NbC coating on steels

    Çelikler üzerine NbC kaplama

    ALİ ATA

    Yüksek Lisans

    İngilizce

    İngilizce

    1992

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    PROF. DR. EMEL GEÇKİNLİ

  4. Topuk Köyü (Orhaneli-Bursa) çevresindeki cevherleşmelerin incelenmesi

    Investigation of the mineral deposits in Topuk Village (Orhaneli-Bursa) surroindings

    ERSİN KOLAY

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    Jeoloji MühendisliğiAnkara Üniversitesi

    Jeoloji Mühendisliği Ana Bilim Dalı

    DOÇ.DR. DOĞAN AYDAL