Geri Dön

Radyasyon doz ölçümleri ve dozimetreler

Radiation dose measurements and dosimeters

  1. Tez No: 754935
  2. Yazar: WALEED KHALID MOHAMMED ALSFOOK
  3. Danışmanlar: PROF. DR. MEHMET ERDOĞAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Radyasyon, Yüzük dozimetre, Rad Fantom, OSL, Dozimetre, Fantomlar, Termoluminesan dozimetri, Radiation, Ring dosimeter, Rad Fantom, OSL, Dosimeter, Phantoms, Thermoluminescent dosimetry
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Radyasyon doz ölçümleri, iyonlaştırıcı radyasyona maruz kalan canlı dokuların, alınan doz miktarına göre aldığı hasarların belirlenmesinde hayati önem taşır. Bu nedenle, doz ölçümlerinde kulla-nılan dozimetrelerin geliştirilmesi ve sınıflandırılması önemlidir. Doz ölçümleri, sağlık alanında tedavi amaçlı, radyasyondan korunma amaçlı, arkeolojik kalıntıların ve tarihi materyallerin yaş tayininde ve uzay araştırmalarında geniş şekilde kullanılmaktadır. Dozimetri kullanımı için, amaca en uygun ve en doğru kullanımın yapılabilmesi için, yapılan araştırmalar önemlidir. Bu çalışmada, dozimetrelerin kulla-nım amacına göre ve fiziksel özelliklerine göre bir sınıflandırılması yapılmıştır. Ayrıca, günümüzde en çok kullanılan dozimetreler TLD (Termolüminesans Dozimetre) ve OSL (Optiksel Uyarmalı Dozimetre) dozimetrelerin fiziksel özellikleri ve doz ölçüm metodları ayrıntılı olarak incelenmiştir. Doz ölçümlerine örnek olarak 5 farklı ISO 4037 standardına sahip yüzük dozimetre (ISO Rad Fantom) ve RADKOR ext dose OSL dosimetre okuyucusu sistemi kullanılmıştır. Bu çalışmada, ışınlanan yüzük dozimetrelerinde cilt dozu (Hp(0,07)) ölçümleri test standardı ISO IEC 62387 baz alınarak gerçekleştirilmiştir. Dozimetre-lerin ışınlanma işlemi ISO 4037-3 baz alınarak Cs-137 ve farklı enerjilerde X-ray (N-40, N-60, N-80, N-100, N-120 ve N-150) ışın setleri kullanılarak gerçekleştiril-miştir. Farklı foton enerjilerindeki doz okuma sonuçları ISO 62387 stanadrdına göre enerji testi veya ISO 14146 standardına göre performans testleri-ne göre analiz edilmiştir. Doz hızı artırıldığında ışınlanma süresinin kısaldığını gözledik. Altı farklı kaynaktan ışınlanan dozlar beş farklı yüzük dozimetre ile ölçülmüş ve bunlar dozimetre okuyucu sistemi tarafından okun-muştur. Yüzük dozimetrelerin ışınlanan ve ölçülen dozlar arasında kararlılık ve güvenirlik belirlenmiştir. Standartlara uygun olarak geliştirilmiş ve kullanıma hazırlanmış kişisel dozimetrelerin güvenle kullanıla-bileceği sonucuna varılmıştır.

Özet (Çeviri)

Dose measurements are vitally important to determine the damage in living tissues exposed to ionizing radiation. Therefore, it is important to develop and classify the dosimeters used in dose measu-rements. Dose measurements are widely used for therapeutic purposes in the field of health, radiation protection, age determination of archaeological remnants, historical materials, and in space research. For the use of dosimetry, researches are important to make the most appropriate and accurate use. In this study, a classification of dosimeters according to their intended use and their physical properties has been made. In addition, the physical properties and dose measurement methods of the mostly used dosimeters TLD (Thermoluminescence Dosimeter) and OSL (Optically Stimulated Dosimeter) dosimeters were examined in detail. As an example of dose measurements, a ring dosimeter (ISO Rad Phantom) and a RADKOR ext dose OSL dosimeter reader system with 5 different ISO 4037 standards were used for dose measurements. In this study, skin dose (Hp(0,07)) measurements in irradiated ring dosimeters were per-formed based on the test standard ISO IEC 62387. The irradiation process of the dosimeters was carried out based on ISO 4037-3, using Cs-137 and X-ray (N-40, N-60, N-80, N-100, N-120 and N-150) beam sets of different energies. The dose reading results for different photon energies were analyzed according to the energy test according to ISO 62387 standard or performance tests according to ISO 14146 stan-dard. We observed that, the irradiation time was shortened when the dose rate was increased. The do-ses irradiated from six different sources were measured with five different ring dosimeters and they were read by the dosimeter reader system. The stability and reliability of the ring dosimeters between the irra-diated and the decanted were determined. It was concluded that personal dosimeters developed in ac-cordance with the standards and prepared for use can be used safely.

Benzer Tezler

  1. Baş boyun kanserlerinde adaptif radyoterapinin doz hacim histogramı ve termolüminesans dozimetreler ile değerlendirilmesi

    Evaluation of adaptive radiotherapy in head and neck cancers with dose volume histogram and thermoluminescence dosimeters

    OSMAN VEFA GÜL

    Doktora

    Türkçe

    Türkçe

    2022

    Radyasyon OnkolojisiSelçuk Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. NİHAL BÜYÜKÇİZMECİ

  2. Linaka dayalı radyasyon tedavisinde 15, 18 ve 21 mev enerjili elektronların çıkış dozlarının farklı dozimetreler ile elde edilmesi ve karşılaştırılması

    Determination and comparison of the output dose of electrons in 15, 18, 21 mev energy using dosimeter systems in radiotheraphy based on linac

    MUHAMMED EMİN NAZLIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. PERVİN ARIKAN

  3. Determination of the radiation dose level to which the lung and liver are exposed in the treatment of liver cancer with the yttrium-90 radioembolization method

    Karaciğer kanserinin yttrium-90 radyoembolizasyon yöntemi ile tedavisinde akciğer ve karaciğerin maruz kaldığı radyasyon doz düzeyinin belirlenmesi

    KAAN SELÇUKHAN SAKMAK

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Radyoloji ve Nükleer TıpYıldız Teknik Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. DR. OSMAN GÜNAY

  4. Girişimsel kardiyoloji incelemelerinde personel radyasyon dozunun ölçülmesi ve hasta radyasyon dozları ile korelasyonu

    Measurement of staff radiation doses in interventional cardiology examinations and correlations with patient radiation doses

    MUSA AY

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DOÇ. DR. TURAN OLĞAR

  5. Bazı floroskopik incelemelerde hasta ve çalışanların aldıkları radyasyon dozlarının saptanması

    Patient and occuoational dosimetry in some fluoroscopic examinations

    GÖKÇE BERKMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2006

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    PROF.DR. DOĞAN BOR