Geri Dön

Farklı yöntemler ile üretilmiş geçici restorasyonlarda: dijital olarak; uyum, doğruluk, kararlılık ve okluzal aşınmanın değerlendirilmesi: İn-vitro çalışma

In temporary restorations made with different methods: digitally; evaluation of fit, accuracy, stability and occlusal wear: İN-vitro study

  1. Tez No: 751510
  2. Yazar: SUAT GÜNGÖR
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MEHMET ESAD GÜVEN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Aşınma, Dental estetik, Dental protezler, Dental restorasyon, Protetik diş tedavisi, Protezler ve implantlar, Sayısal tasarım, Ürün kalitesi, Wear, Dental aesthetics, Dental prosthesis, Dental restoration, Prosthetic dental treatment, Prostheses and implants, Digital design, Product quality
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Necmettin Erbakan Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı; konvansiyonel ve dijital yöntemlerle üreteceğimiz geçici restorasyonların marjinal ve internal uyumlarının karşılaştırılması, restorasyonların doğruluğunun ve kararlılığının kıyaslanması, ayrıca okluzal aşınma miktarının değerlendirilmesidir. Gereç ve Yöntem: Konvansiyonel yöntem, eksiltmeli yöntem, okluzal üretim açısına sahip iki farklı markanın likidi ile eklemeli yöntem, diyagonal üretim acısana sahip iki farklı markanın likidi ile eklemi yöntem olmak üzere 6 grupta toplam 48 adet geçici kuron üretilmiştir. Marjinal ve internal aralık ölçümleri; silikon replika tekniği kullanılarak elde edilen örneklerin, stereomikroskopta (SV-PT Zoom Stereo Microscope, Japonya) x40 büyütme altında alınan görüntülerinin Adobe Photoshop CS6 (Adobe Inc. ABD) yazılımına aktarılması sonrası, bukko-palatinal kesitte toplamda 7 noktadan yapılmıştır. Kuronların iç ve okluzal yüzey üretim hassasiyetinin değerlendirilmesi için; ilk olarak üretilen kuronlar masaüstü bir tarayıcıda (AutoScan Sparkle Jewelry Scanner, Shining 3D, Çin) taranmış, ardından Medit compare yazılımında (Medit, Seul, Kore) tasarlanan ana model ile üst üste hizalamaları yapılarak RMS değerleri elde edilmiştir. Okluzal aşınmanın değerlendirilmesi; çiğneme simülatörü (Analitik Medikal, Gaziantep, Türkiye) ile yaşlandırma işlemi öncesinde ve sonrasında taranan kuronların hacimleri arasındaki farkların Pointshape yazılımı (PointShape 3D Software, Kore) kulanılarak hesaplanması ile yapılmıştır. İstatistiksel analiz için; tek yönlü varyans analiz testi (ANOVA), Post Hoc değerlendirmelerde ise Tukey HSD testi (çoklu karşılaştırma testi) kullanılmıştır. Bulgular: İnternal aralık ölçüm sonuçlarına göre; Grup CC (CAD/CAM) diğer tüm gruplardan anlamlı derecede daha düşük internal aralık değerleri sergilemiştir. Grup CM (konvansiyonel yöntem) ise diğer gruplardan anlamlı derecede yüksek internal aralık değerleri sergilemiştir. 3B baskı yöntemi ile üretilen OTO (Optiprint temp okluzal), OTD (Optiprint temp diyagonal), AO (Asiga okluzal), AD (Asiga diyagonal) grupları arasında ise istatistiksel olarak anlamlı bir fark izlenmemiştir. Marjinal aralık bulgularına göre ise Grup CC, tüm gruplardan istatistiksel olarak anlamlı derecede daha düşük marjinal aralık değerleri sergilemiştir. Grup CM anlamlı derecede en yüksek marjinal aralık değerlerini sergilemiştir. Diğer OTO, OTD, AO, AD grupları ise birbirine benzer marjinal aralık değerleri sergilemiştir. İç yüzey RMS değerlerine göre; Grup CC diğer tüm gruplardan anlamlı derecede düşük RMS değerleri sergilemiş, Grup CM diğer tüm gruplardan anlamlı derecede daha yüksek iç yüzey RMS değerleri göstermiştir. Okluzal üretim açısı ile üretilen Grup OTO ve Grup AO, diyagonal üretim açısı ile üretilmiş Grup OTD ve Grup AD'den daha düşük iç yüzey RMS değerleri göstermişlerdir. Okluzal yüzey RMS değerlerine göre; Grup CC diğer tüm gruplardan anlamlı derecede düşük okluzal RMS değerleri sergilemiş, Grup CM diğer tüm gruplardan anlamlı derecede daha yüksek okluzal yüzey RMS değerleri göstermiştir. Okluzal üretim açısı ile üretilen Grup OTO ve Grup AO diyagonal üretim açısı ile üretilmiş Grup OTD ve Grup AD'den daha düşük okluzal yüzey RMS değerleri göstermişlerdir. Grupların yüzey aşınması sonuçları en düşükten en yükseğe sırasıyla Grup CC, Grup CM, Grup AO, Grup OTO, Grup AD, Grup OTD şeklindedir. Grup CC, Grup CM ve Grup 3B baskı yöntemi iler üretilen gruplar arasında istatistiksel olarak anlamlı fark bulunmuştur. Grup AO, Grup OTO, Grup AD, Grup OTD arasında istatistiksel olarak anlamlı bir fark bulunamamıştır. Sonuç: Bulgulara göre konvansiyonel ve dijital yöntemler ile üretilen geçici restorasyonların marjinal ve internal uyumları yeterli bulunmuştur. İç ve okluzal uyum değerlendirilmesinde Grup CC en iyi sonuçları gösterirken Grup CM en kötü sonuçları göstermiştir. Okluzal yüzey aşınma miktarı ölçümlerinde en az aşınma Grup CC, en fazla aşınma ise 3B baskı yöntemi ile üretilen gruplarda görülmüştür.

Özet (Çeviri)

This study aimed to compare the internal and marginal adaptation, accuracy, presicion and occlusal wear of conventional and digitally prepared temporary restorations. Materıal and Methods: A total of 48 temporary crowns were produced within 6 groups: subtractive method, conventional method, additive method using 2 unique liquids with an occlusal build angle, and another additive method group using 2 unique liquids with a diagonal build angle. Marginal and internal gap measurements were made using 7 points within the bucco-palatal area of the samples which were obtained using the silicone replica technique, observed under a stereomicroscope (SV-PT Zoom Stereo Microscope, Japan) using 40x magnification and transferred to Adobe Photoshop CS6 (Adobe Inc. USA) software. Internal and occlusal surface manufacturing accuracy of the crowns were evaluated using a desktop scanner (AutoScan Sparkle Jewelry Scanner, Shining 3D, China), and the RMS values were obtained by aligning the scans with the main model designed in Medit Compare software (Medit, Seoul, Korea). Occlusal wear was evaluated by comparing the difference between the volumes of the crowns scanned before and after aging with a chewing simulator (Analytik Medikal, Gaziantep, Turkey) and calculated using Pointshape software (PointShape 3D Software, Korea). One-way analysis of variance (ANOVA) for statistical analysis; Tukey HSD test (multiple comparison test) was used in Post Hoc evaluations. (p<0,05) Results: Internal gap values were significantly lower in the CC group (CAD/CAM) in comparison to the other groups while the CM group (conventional method) exhibited significantly higher internal gap values than the other groups. There were no statistically significant differences between OTO (Optiprint temp occlusal), OTD (Optiprint temp diagonal), AO (Asiga occlusal), AD (Asiga diagonal) groups produced using 3D printers. The CC group showed statistically significantly lower marginal gap values than other group while the CM group exhibited the greatest marginal gap values. Other OTO, OTD, AO, AD groups showed similar marginal gap values According to the internal surface RMS values, the CC group exhibited significantly lower RMS values than all other groups while the CM group had higher internal surface RMS values than all other groups. The OTO and AO group produced with an occlusal build angle showed lower internal surface RMS values than OTD and AD group produced with a diagonal build angle. According to the occlusal surface RMS values, the CC group showed significantly lower occlusal RMS values than all other groups while the CM group exhibited significantly higher occlusal surface RMS values than all other groups. The OTO and AO group produced with an occlusal build angle showed lower occlusal surface RMS values than the OTD and AD group produced with a diagonal build angle. The surface wear results were CC, CM, AO, OTO, AD, and OTD group (from lowest to highest respectively). A statistically significant difference was found between the CC and CM groups produced using 3D printing. There was no statistically significant difference between the AO, OTO, AD, and OTD groups. Conclusion: As a result, the marginal and internal fit of the temporary restorations produced by conventional and digital methods were found to be sufficient. In the assessment of internal and occlusal compliance, The CC group gave the best results, while the CM group gave the worst results. In the occlusal surface wear measurements, the least wear was seen in the CC group while most wear was observed in the groups produced using 3D printing

Benzer Tezler

  1. Farklı kenar sonlanma geometrisi ile prepare edilen dişlere konvansiyonel ve dijital yöntemlerle hazırlanan geçici restorasyonlarının uyum ve direnç özelliklerinin değerlendirilmesi

    Evaluation of the adaptation and resistance properties of provisional restorations fabricated via conventional and digital methods for teeth prepared with differentfinish line geometry

    SEMİH HACIOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MEHMET ALİ KILIÇARSLAN

  2. Buğdayda farklı melezleme teknikleri kullanarak tohum tutma oranının saptanılması

    Başlık çevirisi yok

    İSMAİL TÜZÜN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    ZiraatUludağ Üniversitesi

    Tarla Bitkileri Ana Bilim Dalı

    PROF. DR. HALİS RUHİ EKİNGEN

  3. Diyabetus mellitus'da gözlenen mikrovasküler komplikasyonların prostaglandinler ile olan ilişkisi

    The Relation of microvaskular complications observed in diabetes mellitus with prostoglandins

    CANAN NEBİGİL

    Doktora

    Türkçe

    Türkçe

    1985

    Eczacılık ve FarmakolojiCumhuriyet Üniversitesi

    Farmakoloji Ana Bilim Dalı

    YRD. DOÇ. DR. YUSUF SARIOĞLU

  4. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE