Geri Dön

An in vitro evaluation of the effect of different ceramic type, ceramic thickness and aging on color and translucency changes of lithium disilicate, zirconia reinforced lithium silicate, leucite reinforced and feldspathic ceramic veneers.

Farklı seramik tipi, seramik kalınlığı ve yaşlandırmanın lityum disilikat, zirkonya ile güçlendirilmiş lityum silikat, lösit ile güçlendirilmiş cam seramik ve feldspatik seramiklerin renk stabilitesi ve translüsensi üzerine etkisinin ın vitro olarak incelenmesi

  1. Tez No: 748689
  2. Yazar: ŞEYMA TUNA ÜNAL
  3. Danışmanlar: PROF. DR. ESRA CAN EROĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: CAD/CAM, seramik, veneer, renk stabilitesi, translüsens, hidrotermal yaşlandırma, Dental materyaller, Dental porselen, Diş renk değişikliği, Yapay yaşlandırma, İn vitro, CAD/CAM, ceramic, veneers, color stability, translucency, hydrothermal, aging, Dental materials, Dental porcelain, Tooth discoloration, Artificial aging, In vitro
  7. Yıl: 2022
  8. Dil: İngilizce
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Restoratif Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu in vitro çalışmada, iki farklı kalınlıktaki (0,5mm ve 1,0mm) dört farklı CAD/CAM bloğunun hidrotermal yaşlandırma sonrası renk stabilitesi ve translüsens değişimi araştırılarak seramik yapısı, seramik kalınlığı ve yaşlandırmanın etkisi incelenmiştir.Dört farklı CAD/CAM bloğu; lityum disilikat (IPS e.max CAD, Ivoclar Vivadent; E.Max), lösit ile güçlendirilmiş (Initial LRF, GC; LRF), zirkonya ile güçlendirilmiş lityum silikat (Celtra Duo, Dentsply; CD), ve feldspatik (Cerec, Dentsply; CER) cam seramikler 0,5 ve 1,0mm kalınlığında düşük devirli elmas bıçakla (ISOMET) hazırlanmıştır (n=12, her bir kalınlık için). Diş sert dokularını temsil etmesi amacıyla (substrat olarak) 2mm kalınlığında 96 adet mikrohibrit resin kompozit disk (G-eanial, GC; A2) hazırlanmıştır. CAD/CAM blok kesitleri ve resin kompozit substratlar ışık ile polimerize olan rezin siman (G-CEM; GC) ile LED ışık cihazı (VALO Cordless; Ultradent) kullanılarak üretici talimatlarına uygun olarak simante edilmiştir. Simantasyonun hemen ardından ilk renk ölçümleri (E0) spektrofotometre (CM-2600d, Konica Minolta) ile gerçekleştirilmiştir. 37 OC'de distile suda bekletilen monoblok örneklerin (substrat /rezin siman /cam seramik) 24 saat sonra 2. renk ölçümleri (E2) gerçekleştirilmiştir (CM-2600d, Konica Minolta) ve bu ölçümler referans (baseline) olarak alınmıştır. Referans ölçümlerini takiben tüm örnekler 5-55°C arası 30000 siklus hidrotermal yaşlandırmaya maruz bırakılmıştır. Her 10000 siklus arasında (10000, 20000, 30000 siklus sonrası) renk ölçümleri önceki ölçümlerle aynı şekilde gerçekleştirilmiş ve kayıt altına alınmıştır (E1, E2, E3) (CM-2600d, Konica Minolta). Renk değişimi (∆E00) ve translüsens parametresi (TP00) tüm ölçümlerde CIEDE2000 formülü kullanılarak hesaplanmıştır. Veriler üç yönlü ANOVA ve post hoc Tukey's testleri kullanılarak analiz edilmiştir (p<0,05). ∆E00 seramik yapısı (p<0.001), seramik kalınlığı (p<0.001) ve yaşlandırmadan (p<0.001) istatistiksel olarak anlamlı ölçüde etkilenmiştir. Seramik kalınlığı açısından, yalnızca Cerec 0,5mm ve 1,0mm arasında istatistiksel olarak anlamlı fark 10000, 20000 ve 30000 siklus sonrası saptanmıştır (p=0.006, p<0.001, p<0.001, sırasıyla). Seramik yapısı açısından, 0,5mm kalınlıktaki farklı cam seramikler birbirleriyle kıyaslandığında, 10000siklus sonrası LRF, Cerec'ten istatistiksel olarak anlamlı derecede yüksek renk stabilitesi göstermiştir (p=0.001). 20000 ve 30000 siklus sonrası Cerec LRF (p=0.001) ve E.Max'ten (p=0.008, p<0.001) istatistiksel olarak daha az renk stabilitesi göstermiştir (istatistiksel olarak daha fazla renk değişimi).TP seramik yapısı (p<0.001), seramik kalınlığı (p<0.001) ve yaşlandırmadan (p<0.001) istatistiksel olarak anlamlı ölçüde etkilenmiştir. Materyal yapısı, kalınlığı ve yaşlandırma parametreleri arasında anlamlı etkileşim saptanmıştır (p<0.001). Test edilen tüm materyaller kendi içlerinde farklı kalınlıklarında (0,5mm-1,0mm), tüm yaşlandırma periyotlarında istatistiksel olarak anlamlı fark göstermiştir (simantasyondan hemen sonra, Cerec 0.5mm-1.0mm p<0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001. 24 hours (referans ölçüm), Cerec 0.5mm-1.0mm p<0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001. 10000 tsiklus sonrası, Cerec 0.5-1.0 p=0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001. 20000 siklus sonrası, Cerec 0.5mm-1.0mm p<0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001, 30000 siklus sonrası CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001). Cam seramiklerin renk stabilitesi seramik yapısı, seramik kalınlığı ve yaşlandırmadan etkilenmektedir. LRF ve E.Max cam seramiklerin CD ve Cerec materyallerine göre yaşlandırma sonrası renk stabiliteleri daha yüksektir. Cerec bloğunun renk stabilitesi materyalin kalınlığına oldukça yüksek ölçüde bağlıdır. 30000siklus sonrası (3yıl yaşlandırma) 0,5mm kalınlıkta feldspatik seramik en düşük translüsensi gösterirken, 1,0mm kalınlıkta zirkonya ile güçlendirilmiş cam seramik en düşük translüsens değerine ulaşmıştır. Kalınlıklarından bağımsız olarak, simante edilmiş CAD/CAM seramik materyaller 3 yılın sonunda en düşük translüsens değerlerine ulaşmışlardır.

Özet (Çeviri)

The aim of the present study was to evaluate the color stability (CS) and translucency change of different glass-ceramic CAD/CAM blocks in two different thicknesses (0.5mm and 1.00mm) after hydrothermal aging. Four types of CAD/CAM blocks; lithium disilicate (IPS e.max CAD, Ivoclar Vivadent; E.Max), leucite-reinforced (Initial LRF, GC; LRF), zirconia-reinforced lithium silicate (Celtra Duo, Dentsply; CD), and feldspathic (Cerec, Dentsply; CER) glass-ceramics were cut in 0.5mm and 1.00mm slabs (n=12 for each thickness) using a low-speed diamond saw (Isomet). To represent dental hard tissues, a total of 96 micro-hybrid resin composite discs (G-eanial, GC; A2) were prepared in 2mm thickness. CAD/CAM slabs and resin composite substrates were luted with a light-cured resin cement (G-CEM; GC) and polymerized (VALO Cordless, Ultradent) according to the manufacturer's instructions. Immediate after cementation initial color measurements (E0) were evaluated using a spectrophotometer (CM-2600d, Minolta). Following storage in distilled water for 24 hours at 37 OC, second color measurements (E1) were evaluated using a spectrophotometer (CM-2600d, Konica Minolta) and this readings set as baseline measurement. Then all the specimens were exposed to hydrothermal aging between 5-55°C for 30000 cycles (SALUBRİS). Color and TP measurements were repeated after every 10000 cycles (E1, E2, E3). Color differences (∆E) and TP measurements were evaluated by CIEDE2000. Data were analyzed with three-way ANOVA and post hoc Tukey's tests (p<0.05). ∆E00 was significantly influenced by ceramic type (p<0.001), ceramic thickness (p<0.001), and aging (p<0.001). Regarding to ceramic thickness, only CER 0.5mm and 1.0mm showed statistically significant differences at 10000, 20000, 30000 cycles aging (p=0.006, p<0.001, p<0.001, respectively). With respect to ceramic type, in 0.5mm thickness at 10000 cycles LRF showed statistically higher CS than CER (p=0.001), after 20000 and 30000 cycles CER showed statistically lower CS than LRF (p<0.001) and E.Max (p=0.008, p<0.001). TP was significantly influenced by the type of material (p<0.001) by the thickness of the material (p<0.001) and by aging (p<0.001). A significant interaction between material, thickness and aging was found (p<0.001). Meanwhile, the association between material and thickness was significant (p=0.44), whereas between thickness and aging (p=0.124) and between material and aging were not significant (p=0.125). All materials in all aging periods showed statistically significant differences in different thicknesses (postcementation, Cerec 0.5mm-1.0mm p<0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001. 24 hours (baseline), Cerec 0.5mm-1.0mm p<0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001. 10000 thermocycling, Cerec 0.5-1.0 p=0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001. 20000 thermocycling, Cerec 0.5mm-1.0mm p<0.001, CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001, 30000 thermocycling CD 0.5mm-1.0mm p<0.001, E.max 0.5mm-1.0mm p<0.001, LRF 0.5mm-1.0mm p<0.001). CS of glass ceramics were affected by ceramic type, ceramic thickness, and aging. LRF and E.MAX glass ceramics presented more CS then the CD and CER glass ceramic CAD/CAM blocks after aging. CS of the CER CAD/CAM block was highly thickness-dependent. In 0.5mm thickness, feldspathic ceramic showed the lowest translucency, while in 1.0 mm zirconia-reinforced glass ceramic exhibited the lowest translucency after 3-years of aging. Luted CAD /CAM ceramic materials showed acceptable changes in translucency after 3-years of aging, regardless of thickness.

Benzer Tezler

  1. Farklı kimyasal çözücü ajanlarin seramik ortodontik braketlerin debonding ve kopma bölgeleri üzerine etkilerinin in vitro olarak değerlendirilmesi

    In vitro evaluation of the effect of different chemical solvent agents on shear bond strenght of ceramic orthodontic brackets

    HANDE UZUNÇIBUK

    Doktora

    Türkçe

    Türkçe

    2020

    Diş Hekimliğiİstanbul Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. SÜLEYMAN EVREN ÖZTAŞ

  2. Seramik inleylerin farklı rezin simanlarla simantasyonunda ultrasonik yerleştirme tekniğinin dentine mikrotensil bağlanma dayanımı üzerine olan etkisinin in vitro değerlendirilmesi

    In vitro evaluation of effect of the ultrasonic insertion technique on microtensile bond strength of ceramic inlays luting with different resin cements

    EBRU SÜMER

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiDicle Üniversitesi

    Diş Hekimliği Bölümü

    YRD. DOÇ. DR. YALÇIN DEĞER

  3. Farklı adeziv rezin simanların internal renk değişimlerinin-vitro incelenmesi ve mikrosertlik değerlerinin tüm seramik restorasyonlarının ışık geçirme özelliklerinden etkilenme miktarlarının araştırılması

    An in-vitro evaluation of internal color stability and the effect of all-ceramic light transmission characteristics on the microhardness values of various adhesive resin cements

    EVREN KILINÇ

    Doktora

    Türkçe

    Türkçe

    2006

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. ATİLLA KESERCİOĞLU

  4. Silan bağlanma ajanlarının self adeziv rezin siman- cam fiber post arasındaki mikrotensil bağlanma dayanımı üzerine olan etkisinin in-vitro incelenmesi.

    In-vitro evaluation of the effect of silane coupling agents on microtensile bond strength between self adhesive resin cements and glass fiber posts.

    ÇAĞLAR YAŞA

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    Diş HekimliğiYeditepe Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. MÜBİN SOYMAN

  5. Üç boyutlu yazıcıyla farklı rezinler kullanılarak üretilen braketler ile seramik braketlerin renk stabilitesinin In Vitro ortamda karşılaştırılması

    Comparison of color stability of brackets produced using different resins with a 3D printer and ceramic brackets: An In Vitro study

    YAVUZ SELİM GENÇ

    Doktora

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAtatürk Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. ALİ KİKİ