Farklı malzeme ve tekniklerin implant üstü ölçü hassasiyetine etkisinin konik ışınlı bilgisayarlı tomografi ile incelenmesi
Evaluation of the effect of different materials and techniques on implant impression accuracy by cone beam computed tomography
- Tez No: 728094
- Danışmanlar: DOÇ. DR. IŞIL SARIKAYA
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Dental protez-implant destekli, Konik ışınlı bilgisayarlı tomografi, Poliviniller, Ölçüm teknikleri, Dental implantation, Dental implants, Dental prosthesis-implant supported, Cone-beam computed tomography, Polyvinyls, Measurement techniques
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Tokat Gaziosmanpaşa Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı farklı malzeme ve tekniklerin, alınan ölçülerin mesafe ve açı parametreleri karşılaştırılarak ölçü hassasiyetine etkisini değerlendirmektir Gereç ve yöntem: Ölçüler, birbirine paralel yerleştirilmiş 4 implant bulunan akrilik alt çene modeli üzerinden polivinil siloksan (PVS) ve polivinil siloksan eter (PVSE) ölçü materyalleri kullanılarak açık kaşık (AK) ve kapalı kaşık (KK) teknikleri ile alınmıştır. Elde edilen ölçüler konik ışınlı bilgisayarlı tomografi ile taranmış ve OnDemand3D programı ile görüntülenerek ölçümler yapılmıştır. Analoglar ve postlar arasında doğrusal mesafeler ve analog-post komplekslerinin birbirlerine göre açılanmaları ölçülmüştür. Elde edilen veriler referans model görüntüsüyle karşılaştırılmıştır. Normal dağılım göstermeyen değişkenlerin ikili karşılaştırmalarında Mann-Whitney U testi, çoklu grup karşılaştırmalarında Kruskal-Wallis-H testi kullanılmıştır. Bulgular: Analoglar ve postlar arası doğrusal mesafe ölçümlerinde gruplar arası anlamlı düzeyde fark bulunamamıştır. Açısal sapma değerlerinde AK-PVS grubu KK-PVS ve KK-PVSE değerlerine göre anlamlı fark göstermiştir (p<0.05). En az açısal sapma AK-PVS grubunda görülürken (0,195° ± 0,145°), en fazla açısal sapma KK-PVSE de görülmüştür (0,407° ± 0,507°). İmplantlar arası mesafeyle ölçü doğruluğu arasında bir ilişki görülmemiştir. Sonuç: Açık kaşık tekniği, kapalı kaşık tekniğine göre, PVS ölçü materyali PVSE'ye göre daha iyi sonuçlar vermiştir. Açık kaşık ölçü tekniği her iki ölçü materyali için benzer v sonuçlar verirken, kapalı kaşık kullanılan ölçülerde PVS ölçü materyali daha doğru ölçü vermiştir.
Özet (Çeviri)
Aim: The aim of this study is to evaluate the effect of different materials and techniques on the measurement accuracy by comparing the distance and angle parameters of the impressions. Material and Method: Impressions were taken using polyvinyl siloxane (PVS) and polyvinyl siloxane ether (PVSE) impression materials using open tray (AK) and closed tray (KK) techniques on an acrylic mandible model with 4 implants placed parallel to each other. Impressions were scanned with cone-beam computed tomography and displayed with OnDemand3D program and measurements were made. Linear distances between analogs and posts and angulations of analog-post complexes relative to each other were measured. The obtained data were compared with the reference model image. Mann-Whitney U test was used for pairwise comparisons of non-normally distributed variables, and Kruskal-Wallis-H test was used for multi-group comparisons. Results: There was no significant difference between the groups in linear distance measurements between analogs and posts. In angular deviation values, AK-PVS group showed a significant difference compared to KK-PVS and KK-PVSE values (p<0.05). The lowest angular deviation was observed in the AK-PVS group (0.195° ± 0.145°), while the highest angular deviation was observed in the KK-PVSE (0.407° ± 0.507°). There was no correlation between the distance between the implants and the measurement accuracy. vii Conclusions: The open tray PVS showed better results than the closed tray PVS and, close tray PVSE. While the open tray impression technique showed similar results for both impression materials, the PVS impression material gave more accurate impressions in the impressions using closed trays.
Benzer Tezler
- Dijital ölçü aşamasında kullanılan titanyum ve peek tarama gövde materyallerinin yer değiştirmeye bağlı hassasiyetinin değerlendirilmesi
Evaluation of displacement precision of titanium and peek scan body materials used in digital impression
EMRE DİKER
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiAnkara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SEDAT HAKAN TERZİOĞLU
- Alt çene tam dişsizlik olgularında implant üstüne farklı tekniklerle uygulanan bar tutuculu overdenture tasarımlarındaki kuvvet dağılımının sayısal yöntemlerle değerlendirilmesi
Stress distribution evaluation of implant-supported overdenture–retaining bar designs with different techniques in mandibular edentulous cases with numerical methods
GÖZDE YERLİOĞLU
Doktora
Türkçe
2015
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. TOMURCUK ÖVÜL KÜMBÜLOĞLU
- Ti6al4v titanyum alaşımının lazer kaynak kabiliyeti ve biyoaktivite özelliklerinin incelenmesi
Investigation of laser weldability and bioactivity characteristics of ti6al4v titanium alloy
ŞENNUR ARSLAN
Yüksek Lisans
Türkçe
2020
Metalurji MühendisliğiKarabük Üniversitesiİmalat Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ HAYRİYE ERTEK EMRE
- Farklı malzemeler için yenilikçi diz implantı tasarımı ve sonlu elemanlar yöntemi ile optimizasyonu
Innovative knee implant design for different materials and optimisation by finite element method
TURAN IBRAHIMOVA
Yüksek Lisans
Türkçe
2023
Makine MühendisliğiSakarya ÜniversitesiBiyomedikal Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ OSMAN İYİBİLGİN
- Kemik doku mühendisliği uygulamaları için 3B baskı ile polimer-seramik kompozit iskelelerinin geliştirilmesi
Development of polymer-ceramic composite scaffolds using 3d printing for bone tissue engineering applications
ENGİN GEPEK
Doktora
Türkçe
2026
Makine MühendisliğiSakarya ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ OSMAN İYİBİLGİN