Geri Dön

Aging-aware battery dispatch optimization forgrid applications

Başlık çevirisi mevcut değil.

  1. Tez No: 716666
  2. Yazar: VOLKAN KUMTEPELİ
  3. Danışmanlar: PROF. WANG YOUYİ
  4. Tez Türü: Doktora
  5. Konular: Enerji, Energy
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2020
  8. Dil: İngilizce
  9. Üniversite: Nanyang Teknolojı Unıversıtesı (nanyang Technologıcal Unıversıty)
  10. Enstitü: Yurtdışı Enstitü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Özet yok.

Özet (Çeviri)

Day by day the need for autonomy, efficiency, reliability, and sustainability in the power generation, drives researchers to seek alternative energy resources. Therefore, the demand for renewable energy sources (RES) is increasing worldwide, which is followed by the rising contemporary challenges due to the non-dispatchable nature of some of the RESs e.g. solar and wind. In this context, battery storage systems (BESS) appear as a remedy to attenuate the fluctuations caused by the variable power generation. However, despite their rapidly declining prices and improving capabilities, BESSs are yet to be economically feasible in most applications. Thus, their optimized operation plays a major role in reducing their cost. As reported in the literature, there is still a wide gap between BESS and optimization studies. Namely, including state-of-the-art battery aging models within the power system optimization has not been investigated sufficiently. This study presents the construction of an aging-aware energy management system (EMS) for stationary BESSs based on lithium-ion batteries, specifically, lithium-iron-phosphate cells. The EMS incorporates battery degradation costs by using high-fidelity semi-empirical battery models along with a mixed-integer predictive control framework. The proposed method is demonstrated on several grid applications such as energy management in island microgrids and battery dispatch in energy arbitrage markets. Within the island microgrids context, a unique objective function involving various fundamental elements is constructed, and an optimal operating point is pursued using mixed-integer quadratic programming. By leveraging an advanced battery model within the proposed optimization algorithm; diesel generator usage as well as carbon emissions, are minimized. Subsequently, by utilizing in-house experimental results, the cycle-induced battery degradation along with the variable power electronic efficiency is incorporated into the proposed formulation for the optimal battery dispatch problem in energy arbitrage markets. The results highlight that the power electronics efficiency curve has a significant impact on not only the net profit but also the gross profit. Therefore, it should be taken into consideration during the optimization procedure. Lastly, a battery storage system could not be completely represented without adding the temperature effects. Therefore, the used battery model is detailed via removing constant temperature assumption. Hence, the study is finalized by presenting the holistic optimization approach. In summary, this thesis contributes to the literature by investigating the use of advanced lithium-ion battery models in the optimization to pave the way for efficient and effective use of stationary battery storage systems. Hence, it helps to build another bridge between battery and power system optimization researchers.

Benzer Tezler

  1. Strategies for connectivity issues, fault tolerance, and device authentication in drone networks

    Dron ağlarında bağlantı konuları, hata toleransı ve cihaz yetkilendirme için stratejiler

    UMUT CAN ÇABUK

    Doktora

    İngilizce

    İngilizce

    2022

    Elektrik ve Elektronik MühendisliğiEge Üniversitesi

    Uluslararası Bilgisayar Ana Bilim Dalı (disiplinlerarası)

    DOÇ. DR. ORHAN DAĞDEVİREN

    DOÇ. DR. GÖKHAN DALKILIÇ

  2. An adaptive, energy-aware and distributed fault-tolerant topology-control algorithm for heterogeneous wireless sensor networks

    Heterojen kablosuz sensör ağları için uyarlanabilir, enerji seviyesi farkında ve dağıtık hata toleranslı topoloji kontrol algoritması

    FATİH DENİZ

    Doktora

    İngilizce

    İngilizce

    2016

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolOrta Doğu Teknik Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    PROF. DR. ADNAN YAZICI

  3. E-Sense: A wireless sensor network testbed and system for monitoring inbuilding environments

    E-Sense: Kapalı alanlarda ortamı gözleme amaçlı kablosuz algılayıcı ağı test alanı ve sistemi

    BERK BERKER

    Yüksek Lisans

    İngilizce

    İngilizce

    2008

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİhsan Doğramacı Bilkent Üniversitesi

    Bilgisayar Mühendisliği Bölümü

    YRD. DOÇ. DR. İBRAHİM KÖRPEOĞLU

  4. Telsiz ağlarda enerji verimlilikli yeni iletim protokolleri

    Energy-efficient novel transmission protocols for wireless networks

    İBRAHİM AYDIN

    Doktora

    Türkçe

    Türkçe

    2017

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. HASAN ÜMİT AYGÖLÜ

  5. Resilient ultra dense networks under UAV coverage for disaster management

    Afet yönetiminde İHA'lar ile dayanıklı ultra yoğun ağlar

    ELİF BOZKAYA

    Doktora

    İngilizce

    İngilizce

    2020

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BERK CANBERK