İndirekt yapıştırma tekniğinde kullanılan 3 farklı transfer kaşığı ile braket konum doğruluğunun karşılaştırılması
Comparison of bracket position accuracy with THREE types of transfer trays used in indirect bonding tecnique
- Tez No: 710297
- Danışmanlar: PROF. DR. AYÇA ARMAN ÖZÇIRPICI
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: İndirekt yapıştırma tekniği, transfer doğruluğu, transfer kaşığı, 3D tarayıcı, braket konumu, Dental materyaller, Konumlandırma, Ortodonti, Ortodontik aygıtlar, Ortodontik braketler, Üç boyutlu tarayıcı, Indirect bonding, accuracy of transfer, transfer tray, 3D scanner, position of bracket, Dental materials, Positioning, Orthodontics, Orthodontic appliances, Orthodontic brackets, Three dimensional scanner
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Başkent Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Sabit ortodontik tedavi başarısında braketlerin doğru konumlarında yapıştırılmaları oldukça önemlidir. Braketlerin daha doğru konumda yapışmasını sağlamak için indirekt yapıştırma yöntemi kullanılabilir. İndirekt braketleme klinikte geçen süreyi azaltmasından ve braketlerin daha doğru konuma yapıştırılmasına olanak sağlamasından dolayı klinisyenler tarafından sıklıkla tercih edilmektedir. Bu çalışmanın amacı; indirekt yapıştırma tekniğinde kullanılan mevcut ve pratik transfer kaşıklarının konum doğrulukları açısından karşılaştırılmalarıdır. Bu çalışmada üç farklı transfer kaşığı; şeffaf silikon (polivinilsiloksan/Memosil II), vakumla şekillenen çift fazlı (Erkodent) ve kişiye özel bilgisayar ile tasarlanan transfer kaşığı (E-IDB) braket doğruluğu açısından, üç boyutlu tarayıcılar kullanılarak karşılaştırılmıştır. Braketlemeler model üstünde yapılarak aynı hastanın bir başka modeline aktarılmıştır. Transfer öncesinde yapılan tarama ile transfer sonrasındaki taramalar çakıştırılarak doğrusal ve açısal tutarsızlıklar ölçülmüştür. Her diş grubunda Grup 2 (E-IDB), Grup 1 (vakumla şekillenen) ve 3 (memosil)'den anlamlı derecede daha düşük konumsal sapma ve XY (angulasyon), YZ (tork) düzlemlerinde daha düşük açısal sapma göstermiştir. Grup 3, XZ düzleminde (rotasyon) açısal sapma yönünden anlamlı derecede daha yüksek değerlere sahiptir (p<0,05). Tüm gruplarda, açısal sapmalar konumsal sapmalara göre daha fazla bulunmuştur. Molar tüplerde, braketlere göre daha çok konumsal sapma olduğu bulunmuştur. Güncel yaklaşımların, ekstra maliyetlerine karşın yeterli etkinlikte olup olmadığı tartışılmıştır. Bu çalışma indirekt yapıştırma tekniğini kullanan klinisyenler için transfer kaşığı seçiminde faydalı olacaktır.
Özet (Çeviri)
Bonding brackets at a correct position is very important for the success of fixed orthodontic treatment. Using indirect bonding method for bonding brackets can lead to a more accurate position for bonding. Indirect bonding technique is more preferred by clinicians because it helps to reduce the chair time and more accurate positioning of brackets. The aim of this study is to compare the accuracy of the bracket position achieved with current and practical transfer trays which are used in indirect bonding technics. In this study, three different types of transfer trays; transparent silicone (polyvinylsiloxane/ Memosil II), duo phased vacuum formed (Ercodent) and custom designed by computer (E-IDB) has been compared in terms of bracket accuracy by means of three-dimensional scanners. Brackets were bonded on models and has been transferred to another model of the same patient. Linear and angular inconsistencies have been measured by superpositioning of scans before and after transfer. Group 2 (E-IDB) showed significantly lower positional and angular deviations than Groups 1 (double vacuum form) and 3 (memosil) for XY (angulation), YZ (torque) planes. Group 3 has significantly higher values for angular deviation in XZ plane (rotation) for each tooth group (p<0.05). Angular deviations were found to be higher than positional deviations in all study groups. Molar tubes were found to have more positional deviations than brackets. At the end of this study, it will be determined which transfer trays' accuracy is better. It has been discussed whether current approaches are effective enough despite their extra costs. The results of this study will be useful in choosing transfer trays for clinicians who are using indirect bonding.
Benzer Tezler
- İki aşamalı en küçük kareler yöntemi üzerine bir araştırma
Başlık çevirisi yok
SEMRA AKSAKAL
Yüksek Lisans
Türkçe
1986
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolEge ÜniversitesiBilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı
DOÇ. DR. ŞABAN EREN
- Balb/c farelerinin kan serum proteinleri üzerinde UV-C ışınlarının etkilerinin poliakrilamid gel elektroforezi yöntemleriyle incelenmesi
Başlık çevirisi yok
N.ERSİN BAYRAKDAR
- Kobay aortasındaki prostasiklin sentezine amilorid ve analoglarının etkisi
Başlık çevirisi yok
AYDIN AKSOY
Tıpta Uzmanlık
Türkçe
1987
Endokrinoloji ve Metabolizma HastalıklarıGazi Üniversitesiİç Hastalıkları Ana Bilim Dalı
- Ankara Üniversitesi'nde spor yapan öğrencilerin beslenme durumları ve fiziki performansları üzerinde bir araştırma
A Research on the nutritional status and physical performance of the students who were active in sports at the University of Ankara
BÜLENT ASMA
- İnguinal hernili çocuklarda goldstein testi uygulanması
Başlık çevirisi yok
MEHMET PUL
Tıpta Uzmanlık
Türkçe
1987
Çocuk Sağlığı ve HastalıklarıOndokuz Mayıs ÜniversitesiÇocuk Cerrahisi Ana Bilim Dalı