Geri Dön

Kan glikoz değerinin manuel glikometre ve biyokimya laboratuvar analiz sonuçlarının karşılaştırılması ve glikometrenin hayvanlarda kullanılabilirliğinin incelenmesi

Comparison of results of manuel glukometer and biochemistry laboratory analysis of blood glucose levels and research of the availability of glucometer in animals

  1. Tez No: 707527
  2. Yazar: FAZİLET BÜYÜKKAPUCU
  3. Danışmanlar: DOÇ. DR. SİBEL YASA DURU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Veteriner Hekimliği, Veterinary Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Kırıkkale Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Veterinerlik İç Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Köpeklerde glukometre ile ölçülen glukoz değerleri ile biyokimyasal serum glukoz değerlerinin benzer sonuçlar verip vermediğinin ve buna bağlı olarak glukometrenin kan glukoz seviyesi ölçümü için güvenilir olup olmadığının incelenmesi araştırmamızın amacını oluşturmuştur.Çalışmamızın materyalini farklı yaş, cinsiyet ve ırklara 40 sağlıklı köpek oluşturmuştur. Bu köpeklerden en az 8 saat açlıktan sonra açlık kan şekeri ölçümleri için kan örnekleri alınmış, mamalarını yedikten 2 saat sonra tokluk kanları alınmıştır. Alınan kanlardan hemen glukometre ile glukoz ölçümü yapılıp, biyokimyasal analiz için kan örnekleri uygun koşullarda saklanmıştır.Eşleştirilmiş t- testi analiz sonucuna göre açlık değerlerinde iki cihazın ölçüm sonuçları arasında fark olmadığı (p=0,115), tokluk glukoz değerlerinde ise iki ölçüm arasında anlamlı bir fark tespit edildi (p<0,001).Sonuç olarak glukometre ile ölçülen glukoz değerlerinin diabetli hastaların takibinde kullanılabileceğini, bunun hem hasta hem de hasta sahibi açısından pratik ve daha az maliyetli ve zahmetli olduğunu kanısına varıldı.

Özet (Çeviri)

The aim of this study is to determine the similarity of glucose levels measured by glucometer and biochemical serum glucose values in dogs and whether the glucose meter is reliable for blood glucose level measurement.For this study, 40 healthy dogs of in different age, sex, and breeds were used. Blood samples were taken from these dogs for preprandial blood glucose measurements at least 8 hours after feeding, and for postprandial blood was measured 2 hours after feeding. Blood glucose level was measured immediately by glucometer and blood samples were kept under convenient conditions for biochemical analysis.According to the paired t-test results, there was no difference in preprandial blood glucose level both the results of glucometer and biochemical analysis (p = 0.151), and as for postprandial blood glucose level, a significant difference was found between the two measurements (p<0.001).In conclusion, we have found that glucose meter is the most convenient, practical and cheaper method for monitoring patient with diabetes.

Benzer Tezler

  1. Diyabetus mellitus'da gözlenen mikrovasküler komplikasyonların prostaglandinler ile olan ilişkisi

    The Relation of microvaskular complications observed in diabetes mellitus with prostoglandins

    CANAN NEBİGİL

    Doktora

    Türkçe

    Türkçe

    1985

    Eczacılık ve FarmakolojiCumhuriyet Üniversitesi

    Farmakoloji Ana Bilim Dalı

    YRD. DOÇ. DR. YUSUF SARIOĞLU

  2. Atherosklerotik kalp hastalıklarında risk faktörleri

    Risk factors in the coronary artery disease

    MURAT SUHER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    KardiyolojiGazi Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

  3. Alopesia areatalı olgularda tedavi öncesi ve tedavi sonrası immünolojik özellikler

    Başlık çevirisi yok

    AYLA GÜLEKON

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1988

    DermatolojiGazi Üniversitesi

    Dermatoloji Ana Bilim Dalı

  4. Bölgemizdeki normal ve risk gruplarında sifilize karşı oluşan antikorların araştırılması

    Başlık çevirisi yok

    MUSTAFA ZAHİR BAKICI

    Doktora

    Türkçe

    Türkçe

    1984

    MikrobiyolojiCumhuriyet Üniversitesi

    Mikrobiyoloji Ana Bilim Dalı

    PROF. DR. MUVAFFAK AKMAN