Geri Dön

Cam matriks seramik-dentin bağlantı dayanıklılığına baicaleinin etkisi

Effect of baicalein on glass matrix ceramic-dentin bonding strength

  1. Tez No: 707138
  2. Yazar: NURAY ZULKADİR
  3. Danışmanlar: PROF. DR. ASLI SEÇİLMİŞ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Baicalein, Dental bonding, Dental protezler, Dental stres analizi, Dentin, Dimetil sülfoksit, Matriks metalloproteinazlar, Baicalein, Dental bonding, Dental prosthesis, Dental stress analysis, Dentin, Dimethyl sulfoxide, Matrix metalloproteinases
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Gaziantep Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Adeziv bağlantının uzun dönem başarısını artırmak amacıyla matriks metalloproteinaz inhibitörleri kullanarak biyodegradasyonunun önüne geçme fikri güncel bir araştırma konusudur. Bu in vitro çalışmanın amacı matriks metalloproteinaz inhibitörü kullanımının seramik-dentin mikroçekme bağlantı kuvveti üzerine etkisini değerlendirmektir. On altı adet insan mandibular 20 yaş dişinin okluzal minesi prepare edildi ve cam matriks seramik (Celtra Duo) kullanılarak overleyler elde edildi. Dişler 4 gruba ayrıldı. Kontrol grubunda ön işlem uygulanmaksızın total etch, dual cure rezin siman (Variolink N) ile simante edildi. Dimetilsülfoksit ve baicalein grubunda asitleme işleminden sonra çözeltiler uygulandı ve simantasyon, üreticinin talimatları doğrultusunda yapıldı. Baicalein + Ultrasonik aktivasyon grubunda asitleme sonrası baicalein çözeltisi uygulandı, 10 sn ultrasonik aktivasyon yapıldı ve simanın diğer bileşenlerinin baicalein çözeltisiyle aynı penetrasyon derinliğine ulaşması için her aşamada 10 sn ultrasonik aktivasyon yapıldı. Örnekler 5000 devir termal yaşlandırmaya tabi tutuldu. Örnekler kesilerek mikrobar elde edildi ve mikroçekme testi yapıldı. Bağlantı yüzeyi ve ön işlem uygulanmış okluzal yüzey taramalı elektron mikroskobunda görüntülendi. Verilerin normal dağılıma uygunluğu Shaphiro wilk testi ile test edildi normal dağılmayan özelliklerin ikiden fazla bağımsız grupta karşılaştırılmasında ise Kruskal Wallis ve Dunn çoklu karşılaştırma testleri kullanıldı (P<0.05). Kontrol grubu bağlantı dayanıklılığı değerleri diğer üç gruba oranla anlamlı derecede yüksek bulundu. Çalışma sonucunda % 0.1'lik dimetilsülfoksit ve 12.5 μmol/L'lik baicalein çözeltilerinin cam matriks seramik ile dentinin; total etch, dual cure rezin siman (Variolink N) ile simantasyonunda kullanımı önerilmemiştir. Cam matriks seramik-dentin bağlantı dayanıklılığını artırmak için farklı rezin simanlar ve farklı baicalein dozlarıyla daha fazla çalışmaya ihtiyaç duyulmaktadır.

Özet (Çeviri)

In order to increase the long-term success of the adhesive bond, the idea of preventing biodegradation by using matrix metalloproteinase inhibitors is a current research topic. The aim of this in vitro study was to evaluate the effect of matrix metalloproteinase inhibitor use on the ceramic-dentin microtensile bond strength. The occlusal enamel of sixteen human mandibular wisdom teeth was prepared and overlays were obtained using glass matrix ceramic (Celtra Duo). Teeth were divided into 4 groups. In the control group, was cemented with total etch, dual cure resin cement (Variolink N) without pretreatment. In the dimethyl sulfoxide and baicalein group, solutions were applied after etching and cementation was done according to the manufacturer's instructions. In the Baicalein + Ultrasonic activation group, after etching, baicalein solution was applied, ultrasonic activation was performed for 10 seconds and ultrasonic activation was performed for 10 seconds at each stage so that the other components of the cement reached the same penetration depth with the baicalein solution. The samples were subjected to 5000 cycles of thermal aging. Microbar was obtained by cutting the samples and micro-tensile test was performed. The junctional surface and pretreated occlusal surface were visualized in a scanning electron microscope. The conformity of the data to the normal distribution was tested with the Shaphiro Wilk test, and the Kruskal Wallis and Dunn multiple comparison tests were used to compare the non- normally distributed features in more than two independent groups (P<0.05). Connection strength values of the control group were found to be significantly higher than the other three groups. As a result of the study, the use of 0.1% dimethylsulfoxide and 12.5 μmol/L baicalein solutions in glass matrix ceramic and dentin; total etch, dual cure resin cement (Variolink N) cementation was not recommended. More studies are needed with different resin cements and different baicalein doses to increase the durability of the glass matrix ceramic-dentine joint .

Benzer Tezler

  1. Çeşitli yüzey işlemleri uygulanan Rezin Matriks seramiklerin rezin siman kullanılarak dişe bağlantılarının in-vitro olarak incelenmesi

    In-vitro evaluation of shear bond strength of Resin Matrixceramics with different surface treatment methods

    ELİF MELİKE AKARCA

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. RAGİBE ŞENAY CANAY

  2. Rezin matriks seramiklerin yorulma dayanıklılıklarının in-vitro olarak değerlendirilmesi

    Rin-vitro evaluation of fatigue strength of resin matrix ceramics

    MERVE KÖSEOĞLU ŞAHİN

    Doktora

    Türkçe

    Türkçe

    2018

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. RAGİBE ŞENAY CANAY

  3. CAD/CAM sistemlerinde kullanılan 4 farklı seramik materyalin kompozit rezin ve kendinden adeziv rezin siman ile yapıştırılması takiben termal yaşlandırma işlemi öncesi ve sonrası bağlanma dayanımları karşılaştırılması

    Comparison of binding strengths before and after the thermal ageing process following the bonding of 4 different ceramic materials used in CAD/CAM systems with composite resin and self-adhesive resin cement

    MURAT ŞENOL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. AYHAN GÜRBÜZ

    PROF. DR. PELİN ÖZKAN

  4. Asidik pH'nın rezin matriks seramiklerin yüzey özelliklerine etkisinin değerlendirilmesi

    Evaluation of the effect of acidic pH on the surface properties of resin matrix ceramics

    KÜBRA NUR TAD

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. AYHAN GÜRBÜZ

  5. Yeni jenerasyon restoratif materyaller kullanılarak bilgisayar yardımıyla tasarlanan ve üretilen kron restorasyonların, 3 boyutlu görüntü hizalama yöntemiyle klinik aşınma miktarlarının incelenmesi

    Examining clinically surface wear amount of crown restorations produced by CAD&CAM method using new jeneration restorative material with 3 dimensional image aligning

    DİDEM OĞUZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. AKIN ALADAĞ