Geri Dön

Ayak bileği ve ayak tabanı ligamentlerinden“Tibionavicular”,“Tibiocalconear”,“Calconeofibular”ve“Plantare Longum”un mekanik özelliklerinin mukayeseli incelenmesi

Comparative analysis of mechanical properties of the ankle and the sole ligaments“Ligamentum Tibionavicular”,“Ligamentum Tibiocalcenoar”,“Ligamentum Calconeofibular”and“Ligamentum Plantare Longum”

  1. Tez No: 69193
  2. Yazar: NUSRET RAMAZANOĞLU
  3. Danışmanlar: PROF. DR. A. HİKMET ÜÇIŞIK
  4. Tez Türü: Doktora
  5. Konular: Spor, Sports
  6. Anahtar Kelimeler: Ayak, Ayak bileği, Ligamentler, Tendonlar, Foot, Ankle, Ligaments, Tendons
  7. Yıl: 1998
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Beden Eğitimi ve Spor Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Ayak bileği ligamentterinin ve bir adet ayak tabanı ligamentinin mekanik özelliklerini belirlemek amacı ile insan kadavralarından alınan dört farklı ligament (Tibiocalcanear,- Tibionavicular, Calcaneofibular ve Plantar Ligamentler) Instron universal Mekânîk Test rCîhazT ite mekanik deneylere tabi tutuldu. Ligamentler kadavralardan alındıktan sonra, deney aşamasına kadar formaldehitte saklandı. Ligamentler tek yönlü çekme deneyine tabi tutuldu. Bu esnada ligamentin;“Gerilme-Şekil Değişimi”münasebeti, elastisite modülü, yükün uzama değişimine oranı ve deneyler esnasında ligamentte absorbe edilen enerji miktarları, Instron Mekanik Test Cihazının çene hızında ani değişmeler (strain-rate) yapılarak incelenmiştir. Deneyler esnasında ligamentlerin farklı bölümlerinin hareket özelliklerini incelemek için her ligamentin üzerine, çini mürekkebi ile matris şeklinde noktalar konulmuştur. Bu noktaların; yükleme ve çene hızlarındaki ani değişmeler (strain-rate) esnasındaki hareketleri incelenmiştir. Ligamentlerin mekanik özelliklerini belirlemek için her ligamente en az bir, en çok yedi periyotta (“Yükleme-Boşaltma”devresi) yük uygulanmıştır. Bu periyotları takiben, ligamentlerin kopma noktasını belirlemek amacı ile kopma meydana gelinceye kadar yük uygulamaya devam edilmiştir. vııDeneyleri bilahare analiz edebilmek için deneyler video kamera ile kayda alınmıştır. Kayda alınan deneyler daha sonra özel bilgisayar programları ile analiz edilmiştir. Bu veriler neticesinde ligamentlerin;“Gerilme-Şekil Değişimi”hali, elastisite modülü, yükün uzama değişimine oranı ve deneyler esnasında ligamentte absorbe edilen enerji miktarları Instron Mekanik Test Cihazının çene hızındaki ani hız değişimlerinde incelenmiştir. Ligamentlerin mekanik özellikleri, gerilme, şekil değişimi, elastisite modülü, Yükün uzama değişimine oranı ve deneyler esnasında ligamentte absorbe edilen enerji miktarları, her bir ligament için farklı olarak tesbit edilmiştir. Yükleme-yük boşaltma esnasında çene hızındaki ani değişmeler, ligamentlerin“Gerilme- Şekil Değişimi”eğrilerinin eğiminde belirgin artışlara ve azalmalara yol açmıştır. Matris elemanlarının hareketleri incelendiğinde; Instron Universal Mekanik Test Cihazının çene hızındaki ani hız değişimleri ve dönüşümü olmayan hasar (kopma) anındaki hareketleri anizotropik bir malzeme özelliği gösterdiği tesbit edilmiştir. vııı

Özet (Çeviri)

COMPARATIVE ANALYSIS OF MECHANICAL PROPERTIES OP THE ANKLE AND THE SOLE LIGAMENTS“LİGAMENTUM TİBİONAVİCULARİSnI ”LİGAMENTUM TİBİOCALCANEARİS“, ”LİGAMENTUM CALCANEOFİBULARE“ AND ”LİGAMENTUM PLANTARE LONGl|MM ABSTRACT Four different ankle ligaments obtained from human cadavers were kept in a formaldehyde (10%) solution until mechanical testings run by using Instron Universal Mechanical Testing Machine. Addition to the conventional tensile test, periodic loadings under load control were applied. Prior all the tests run, on each ligament a matrix type of markings by using Chinese ink were created, so that, not only bulk mechanical properties, properties of individual different parts of ligaments have been obtained aş a function of stressings, strainings and time, results obtained from matrix mentioned are directly related with the anisotropic properties ligaments. To be able to analyze of what experiments provided, a computer program was prepared. During experiment a video camera connected to computer was used to record the data which were analyzed after experiment run. Monotic loading- unloading cycles showed that sudden strain rate changes change stiffness of ligaments and the area of hysteresis loop decreases with cycles. Movements of the elements of matrix is no linearly depended. It is observed that quantitative values of the all changes of the experimental parameters are not same; thus all the ligaments studied have highly anisotropic structure. IX

Benzer Tezler

  1. İnsanda fötal epidermis ve eklentilerinin farklı anatomik bölgelerdeki histomorfometrik analizi

    Başlık çevirisi yok

    M. SULTAN MERMER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1997

    MorfolojiSelçuk Üniversitesi

    Histoloji ve Embriyoloji Ana Bilim Dalı

    DOÇ. DR. SELÇUK DUMAN

  2. Deri malign melanomları prognozu belirleyen klinik, histopatolojik ve histometrik bulguların araştırılması

    Başlık çevirisi yok

    EMEL DİKİCİOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1990

    PatolojiEge Üniversitesi

    PROF.DR. GÜLŞEN KANDİLOĞLU (ÇORUH)

  3. Bilişim sistemlerindeki gelişmelerin işletme yönetimine etkileri, yönetim bilişim sistemleri geliştirme ve bir uygulama örneği

    Effects of the evoluation of information systems on management, management information systems development and an example of its application

    ZUHAL TANRIKULU

    Doktora

    Türkçe

    Türkçe

    1999

    İşletmeİstanbul Üniversitesi

    İşletme Yönetimi ve Organizasyon Ana Bilim Dalı

    PROF. DR. EROL EREN

  4. Bilgi çağına girerken elektronik ticaret ve bankacılıkta bir uygulama

    Electronic commerce as passing to information age and banking application example

    ÖNDER DİKBAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    EkonomiGazi Üniversitesi

    İktisat Teorisi Bilim Dalı

    YRD. DOÇ. DR. NEJAT COŞKUN

  5. Teknoparkların dünyadaki durumu ve Türkiye'de uygulanabilirliği

    Başlık çevirisi yok

    MUSTAFA AY

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Makine MühendisliğiGazi Üniversitesi

    PROF.DR. METİN GER