Geri Dön

Mandibulada all-on-four ve trefoil konseptlerinin farklı oklüzyon koşullarda yüklenmesiyle oluşan streslerin sonlu elemanlar analizi ile değerlendirilmesi

Başlık çevirisi mevcut değil.

  1. Tez No: 691334
  2. Yazar: BERNA DERİNPINAR
  3. Danışmanlar: DOÇ. DR. MEHMET MUSTAFA ÖZARSLAN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental oklüzyon, Dental stres analizi, Mandibula, Sonlu elemanlar stres analizi, Dental occlusion, Dental stress analysis, Mandible, Finite elements stress analysis
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Akdeniz Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı, All-on-Three ve All-on-Four olmak üzere iki farklı implant destekli sabit protez konseptinde dört farklı yükleme koşulunda kemik, implant ve vida üzerinde oluşan maksimum stresleri araştırmaktır. Yöntem: Üç boyutlu mandibular modeller All-on-Four ve All-on-Three konseptine göre tasarlandı. Maksimum interkuspal pozisyon, kanin koruyuculu oklüzyon, grup fonksiyonlu oklüzyonu ve kantilever yüklemesi koşulları altında temas noktalarına maksimum ısırma kuvvetleri uygulanmıştır. Kortikal kemik üzerindeki maksimum gerilimler ve implant ve vida üzerindeki von Mises stres gerilimleri, sonlu elemanlar analizi yöntemi kullanılarak farklı oklüzyonlar arasında karşılaştırmalı olarak hesaplanmıştır. Bulgular: Maksimum ısırmada en yüksek stres seviyeleri, All-on-Three modelinin distal implantlarında bulundu. All-on-Three sistemindeki anterior implant, vida, kortikal kemik, All-on-Four sistemindeki anterior implant, vida ve kemiğe göre 4 kat daha fazla stres değerleri hesaplandı. Tüm gruplarda kanin koruyuculu oklüzyonda, çalışan tarafta daha yüksek stres değerleri gözlendi. İmplant ve kemik seviyelerinde stres konsantrasyonları her iki modelde de benzerdi. Bununla birlikte, All-on-Three modelinde merkezi implant vidasında önemli ölçüde daha yüksek stres seviyeleri gözlemlendi. Grup fonksiyonlu oklüzyonunda, All-on-Three sisteminde implant, vida ve kemik seviyelerinde daha yüksek stres konsantrasyonları gözlenirken, çalışma tarafında daha yüksek stres seviyeleri gözlendi. Kantilever yüklemede; All-on-Three modelinde önemli derecede abutment vida stresleri bulundu. Öte yandan, All-on-Four modelinde distal implantlar ve çevreleyen kortikal kemik çevresinde maksimum stres değerleri gözlendi. Grup fonksiyonlu oklüzyon, tüm yapılar içinde daha yüksek gerilimlere sahiptir. Sonuç: Bu çalışmanın sınırlamaları dahilinde, All-on-Four ve All-on-Three sistemlerde kortikal kemik, vidalar, implantlardaki stresler göz önüne alındığında kanin koruyuculu oklüzyon uygulanması önerilebilir. İmplant destekli protezler için optimal oklüzyon tipinin uzun süreli klinik deneylerle araştırılması gerekmektedir.

Özet (Çeviri)

Objective: The aim of this study was to investigate the maximum stresses that occur on the bone, the implant and the screw under four loading conditions in two different implant supported fixed prosthesis concepts, All-on-Three and All-on-Four. Method: Three dimensional mandibular models were designed according to All-on-Four and All-on-Three concept. Maximum bite forces were applied to the contact points under the conditions of maximum intercuspal position, canine protective occlusion, group function occlusion and cantilever loading. The maximum principal stresses on cortical bone and Von Mises stresses implant and screw were calculated comparatively between different occlusions using the finite element analysis method. Results: The highest stress levels at maximum bite forces were found in the distal implants of the All-on-Three model. The anterior implant, screw, cortical bone in All-onThree system was calculated to 4 times more stress than the anterior implant, screw and bone in the All-on-Four system. Canine-protected occlusion, higher stresses were observed on the working side in all groups. At the implant and bone levels, stress concentrations were similar in both models. However, significantly higher stress levels were observed around the screw of the central implant in the All-on-Three model. In the group-function occlusion, higher stress concentrations were observed at the implant, screw and bone levels in the All-on-Three system, with higher stress levels observed on the working side. Cantilever loading; significant level abutment screws stresses was found the All-on-Three model. On the other hand, maximum stress values were observed around the distal implants and the surrounding cortical bone in the All-on-Four model. Group function occlusion caused higher stresses for all structures. Conclusion: Within the limitations of this study, it may be suggested apply a canine protected occlusion when stresses in the cortical bone,screws, implants are considered in All-on-Four and All-on-Three systems. The optimal occlusion type for implant prostheses needs to be investigated with long-term clinical trials.

Benzer Tezler

  1. Tam dişsiz mandibulaya uygulanan all-on-four ve trefoil sistemlerinin implantlar ve çevre dokularda oluşan streslere etkilerinin sonlu elemanlar analizi ile incelenmesi

    Investigation of the effects of all-on-four and trefoil systems applied to atoothless mandibula on stress occurring i̇n implants and surrounding tissueswith finite element analysis

    KEMAL KARAKÖSE

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiAtatürk Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ GELENGÜL URVASIZOĞLU

  2. İmplant destekli overdenture uygulamaları ve all-on-four sisteminin atrofik mandibulada frontal travmatik kuvvet sonucu oluşan stresler üzerine etkilerinin sonlu elemanlar analizi ile incelenmesi

    Effects of implant supported overdenture applications and all-on-four systemon the response to frontal traumatic force in atrophic mandible: Threedimensional finite element analysis

    MUSTAFA SEÇKİN YAZAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiAtatürk Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ERTAN YALÇIN

  3. Evaluation with finite element analysis of stresses generated by ımplants with different angles and lengths applied with the all on four technique in atrophic mandible

    Atrofi̇k mandi̇bulada all on four tekni̇ği̇ i̇le uygulanan farkli açi ve boydaki̇ i̇mplantlarla oluşan stresi̇n sonlu elemanlar anali̇zi̇ i̇le değerlendi̇ri̇lmesi̇

    TOURGKAI MOUSTAFA

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. GÜLSÜM AK

  4. Çift taraflı atrofik mandibulada farklı kemik volümetrelerinde all-on-four tekniği ile yerleştirilen dental implantların çevre dokularda oluşturduğu streslerin sonlu elemanlar analizi ile incelenmesi

    Evaluation of stress distribution around a dental implant with different amounts of bone by“all on four”technique applied in bilateral atrophic mandible by using finite element analysis

    OSMAN YAVUZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiDicle Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. BEYZA KAYA

  5. Atrofik mandibulada 'All-on-Four' konsepti ile alternatif tedavi protokollerinin sonlu elemanlar stres analizi yöntemi ile karşılaştırılması

    Evaluation of stress distribution on All-on-Four concept and conventional implant designs: finite element analysis

    İLHAN KAYA

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiAnkara Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. ESER FUNDA TUĞCU