İki farklı elektronik kök ucu bulucunun kalsiyum silikat esaslı kök kanal patlarının sökümü sırasındaki performanslarının karşılaştırılması
Comparative analysis of two different apex locaters during removal of calcium silicate based root canal sealers; an in vitro study
- Tez No: 685992
- Danışmanlar: DR. ÖĞR. ÜYESİ PARLA MEVA DURMAZPINAR
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Apeks bulucu, çalışma boyu, kalsiyum silikat bazlı patlar, Dental debonding, Diş apeksi, Kalsiyum silikat, Kök kanal dolgu materyalleri, Kök kanal tedavisi, Apex locators, apical constraction, calcium silicate based sealers retreatment, Dental debonding, Tooth apex, Calcium silicate, Root canal filling materials, Root canal therapy
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
İki Farklı Elektronik Kök Ucu Bulucunun Kalsiyum Silikat Esaslı Kök Kanal Patlarının Sökümü Sırasındaki Performanslarının Karşılaştırılması Öğrenci Adı: Pelin Andaç Göçer Danışman Adı: Dr. Öğr. Üyesi Parla Meva Durmazpınar Amaç: Kök kanal tedavisi tekrarındaRetreatmentta çalışma uzunluğunun yeniden belirlenmesi tedavinin prognozu açısından oldukça önemlidir. Ancak kök kanalı dolumunda kullanılan kanal patları retreatmantta apeks bulucuların ölçüm doğruluklarını etkileyebilir. Bu çalışmanın amacı da farklı kanal dolgu patlarıyla doldurulan kanallarda retreatment işlemi sırasında farklı apeks bulucuların etkinliklerini karşılaştırmaktır. Gereç ve yöntem: Çalışmamızda 90 tane çekilmiş insan dişinin kök kanalları Protaper (Dentsply Maillefer, Ballaigues, Switzerland) SX, S1, S2, F1 ve F2 döner eğeleri ile genişletildi.şekillendirildi ve %5,25 NaOCl ile irrigasyon yapıldı. Kök kanalları patı olarak MTA Fillapex (Angelus, Londrina, Brazil), Ceraseal (Meta Biomed Co., Korea) veya AH Plus (Dentsply, Germany) patları kullanıldıile dolduruldu. Dişler 7 gün %100 nemli ortamda 37ᵒC'de inkübatörde tutulduktan sonra kanal dolumları söküldü. Dişlerin rRetreatment prosedüründen sonra direkt gözlemle asıl çalışma boylarıu (AÇB) kaydedildilirken,. Propex Pixi (Densply, Tulsa, OK) ve Root ZX (Morita, Tokyo, Japan) ile yapılan ölçümlerle de EÇB (elektronik çalışma boylarıu) (EÇB) belirlendi. Elde edilen vve verilerin istatistiksel analizleri p<0,05 anlamlılık düzeyinde değerlendirildi. Bulgular: MTA Fillapex, AH Plus ve Cereseal patları kullanılan kanallarda asıl çalışma boyu ile Propex Pixi ve Root ZX çalışma boyları sıra ortalamaları arasında istatistiksel olarak anlamlı bir farklılık bulunamadı (p>0,05). Kalsiyum silikat bazlı kök kanal patlarının Propex Pixi ve Root ZX'in ölçüm performanslarına istatistiksel olarak anlamlı etkileri bulunamamıştır (p><0,05). Sonuç: Kanal dolumunda kullanılan pat farketmeksizin, retreatment sırasında çalışma boyununu doğru şekilde belirlemede Propex Pixi ve Root ZX kullanımı önerilebilir.
Özet (Çeviri)
Comparative Analysis of Two Different Apex Locaters During Removal of Calcium Silicate Based Root Canal Sealers; An In Vitro Study Student name: Dt. Pelin Andaç Göçer Name of Supervisor: Asst. Prof. Parla Meva Durmazpınar Objective: Determining the working length during endodontic retreatment is very important in the prognosis of the treatment. The aim of this study is to evaluate the accuracy of Root ZX and ProPex Pixi during retreatment of canals obturated with different calcium silicate based materials. Material and methods In our study, 90 extracted human teeth instrumentated by Protaper (Dentsply Maillefer, Ballaigues, Switzerland) SX, S1, S2, F1 and F2 rotary files and irrigated with %5.25 NaOCl. Root canals were filled with gutta percha and MTA Fillapex (Angelus, Londrina, Brazil), Ceraseal (Meta Biomed Co., Korea) or AH Plus (Dentsply, Germany). After the teeth were kept in an incubator at 37ᵒC in a 100% humidity environment for 7 days, the canal fillings were removed and two different working lengths were determined. Actual working length (AÇB) was recorded by direct observation. Electronic working length (EÇB) was determined with Propex Pixi (Densply, Tulsa, OK) and Root ZX (Morita, Tokyo, Japan). Statistical analyzes of the obtained data were evaluated at p<0.05 significance level. Results: There was no statistically significant difference between MTA Fillapex, Ceraseal and AH Plus sealers in terms of affecting the measurements of the Propex Pixi and Root ZX (p>0.05). Calcium silicate based root canal sealers did not have statistically significant effects on the measurement performances of Propex Pixi and Root ZX (p>0.05).
Benzer Tezler
- Application of human mesenchymal stem cells to 3D silk fibroin scaffolds for cardiac tissue engineering
İnsan mezenkimal kök hücrelerinin 3B ipek fibroin yapı iskelelerine uygulanarak kardiyak doku mühendisliğinde kullanılması
GİZEM MERVE ŞAHİN
Yüksek Lisans
İngilizce
2017
Biyomühendislikİstanbul Teknik ÜniversitesiMoleküler Biyoloji-Genetik ve Biyoteknoloji Ana Bilim Dalı (disiplinlerarası)
DOÇ. DR. FATMA NEŞE KÖK
DR. YÜKSEL ÇETİN
- İki farklı tipte elektronik apex locatorın, çeşitli çapta fizyolojik foramene sahip dişlerde kök kanalları kuru iken ve NaOCI ile dolu iken farklı tipte ve çaptaki kök kanalı aletleri kullanılarak doğruluklarının değerlendirilmesi
Evauation of two types of apex locators using different types and diameters of root canal instruments while the root canals are dry and filled with NaOCI in teeth with physiological foramina of different diameters
MELİH BAYRAKCI
- Üç farklı elektronik apeks bulucu, radyovizyografi ve konik ışınlı bilgisayarlı tomografinin süt dişi kök kanal tedavisinde çalışma boyu belirlenmesinde doğruluğunun değerlendirilmesi
The accuracy of three different electronic apex locators, radiovisiography and cone-beam computed tomography in determination of the working lenght measurement on primary teeth root canal treatment
MEVLÜT KAYABAŞI
Diş Hekimliği Uzmanlık
Türkçe
2019
Diş HekimliğiSivas Cumhuriyet ÜniversitesiÇocuk Diş Hekimliği Ana Bilim Dalı
DOÇ. DR. FATİH ÖZNURHAN
- A novel rotationally oscillating micro drill for microinjection operations
Mikroenjeksiyon operasyonları için yeni bir rotasyonel osilasyonlu mikro delici
HANDAN NAK
Doktora
İngilizce
2020
Biyomühendislikİstanbul Teknik ÜniversitesiKontrol ve Otomasyon Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ALİ FUAT ERGENÇ
- Localization of biopsy needles in 2D ultrasound images using gabor filter
Biyopsi iğnelerinin gabor filtresi kullanılarak 2B ultrason görüntülerinde lokalize edilmesi
MERT KAYA
Yüksek Lisans
İngilizce
2015
Elektrik ve Elektronik MühendisliğiÖzyeğin ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. ÖZKAN BEBEK