Lens gücünün yeni biometri formülleri kullanılarak hesaplanması

Calculation of lens power using new biometry formulas

  1. Tez No: 685352
  2. Yazar: ELİF ERGÜL
  3. Danışmanlar: PROF. DR. NİLÜFER GÖZÜM
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Göz Hastalıkları, Eye Diseases
  6. Anahtar Kelimeler: Biyometri, Fakoemülsifikasyon, Göz, Göz hastalıkları, Katarakt çıkartılması, Lensler, Biometry, Phacoemulsification, Eye, Eye diseases, Cataract extraction, Lenses
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Hastaların fakoemülsifikasyon cerrahisi öncesindeki biometrik ve refraktif verileri kullanılarak; 6 farklı biometrik formül ile göz içi lens (GİL) gücünün hesaplanması ve formüllerin cerrahi sonrası refraktif sonuçlara göre doğruluklarının karşılaştırılması. Gereç ve Yöntem: Ocak 2016 – Temmuz 2019 tarihleri arasında İstanbul Üniversitesi İstanbul Tıp Fakültesi Göz Hastalıkları kliniğinde katarakt tanısı konup fakoemülsifikasyon cerrahisi uygulanan 43 hastanın 65 gözünün verileri retrospektif olarak incelendi. Sonuçlar: Çalışmaya alınan 43 hastanın yaş ortalaması 64,65 ± 8,23 (47-86) yıl idi. Ortalama aksiyel uzunluk 23,5±0,7 mm (22,01-24,5) olarak saptandı. Hastalarda hedeflediğimiz refraksiyon değerine karşılık gelen GİL gücü SRK/T formülüne göre hesaplandı. Postoperatif 3. ay ve sonrasında yapılan muayeneler ile hastaların sonuç refraksiyon değerleri saptandı. Hastaların preoperatif en iyi düzeltilmiş görme keskinliği (EİDGK) 0,44±0,4 logMAR iken, postoperatif EİDGK 0,08±0,04 idi ve anlamlı bir artış mevcuttu (p<0,001). Hastaların optik biometri ölçümleri kullanılarak, aynı kırma gücüne sahip GİL implante edildiğinde, Hoffer Q, T2, Ladas Süper Formülü, Barrett Universal II ve Hill-RBF formülleriyle ortaya çıkacak hedef refraksiyon değerleri not edildi. Kullanılan formüllerin saptadığı hedef refraksiyon değerleri ile hastaların sonuç refraksiyonlarının sferik eşdeğerleri arasındaki fark not edildi ve formüller arasındaki refraktif sapma değerleri karşılaştırıldı. SRK/T formülü kullanıldığında refraktif sapma 0,29±0,29 D, T2 formülü ile 0,27±0,27 D, Hoffer Q ile 0,3±0,24 D, Ladas Süper Formülü ile 0,3±0,26 D, Barrett Universal II formülü ile 0,33±0,28 D, Hill-RBF formülü ile 0,27±0,29 D olarak saptandı. Formüllerin refraktif sapma derecelerinin -0,50 D ile +0,50 D aralığında olduğu vakaların yüzdeleri şu şekildeydi: %87,7 ile T2 formülü, %86,2 ile Hill-RBF, %84,6 ile Hoffer Q ve SRK/T formülleri, %83,1 ile Barrett Universal II, %81,5 ile Ladas Süper Formülü. Formüllerin -1.00 D ile +1.00 D aralığında çıkan refraktif sapma yüzdeleri ise şu şekilde saptandı: %98,5 ile Hoffer Q ve Hill-RBF, %96,9 ile T2 formülü, Ladas Süper Formülü, Barrett Universal II ve SRK/T formülü. Refraktif sapma değerleri açısından formüller arasında istatiksel olarak anlamlı bir farklılık izlenmedi (p>0,05). Tartışma: Çalışmada yer alan 6 biometri formülünün ±1 D içinde refraktif sapma ile hedef refraktif değere ulaşma şansı %96,9 düzeyi ve üzerindedir. Bu formüllerin her biri normal uzunluktaki gözlerde preoperatif GİL gücünü hesaplamak için güvenli bir şekilde kullanılabilir.

Özet (Çeviri)

Purpose: Using the biometric and refractive data of the patients before the phacoemulsification surgery; calculation of the intraocular lens (IOL) power with 6 different biometric formulas and comparison of the accuracy of the formulas according to the postoperative refractive results. Material and Method: The data of 65 eyes of 43 patients who were diagnosed with cataract and underwent phacoemulsification surgery in the Ophthalmology Clinic of Istanbul University Istanbul Faculty of Medicine between January 2016 and July 2019 were retrospectively analyzed. Results: The mean age of 43 patients included in the study was 64,65 ± 8,23 (47-86) years. The mean axial length was found to be 23,5±0,7 mm (22,01-24,5). The IOL power corresponding to the target refraction value in the patients was calculated according to the SRK/T formula. Result refraction values of the patients were determined by the examinations performed at and after the postoperative 3rd month. While the preoperative best corrected visual acuity (BCVA) of the patients was 0,44±0,4 logMAR, the postoperative BCVA was 0,08±0,04 and there was a significant increase (p<0,001). Using the optical biometry measurements of the patients, the target refraction values that would emerge with the Hoffer Q, T2, Ladas Super Formula, Barrett Universal II and Hill-RBF formulas when implanted with the same refractive power were noted. The difference between the target refraction values determined by the formulas used and the spherical equivalents of the patients' result refractions was noted and the refractive deviation values between the formulas were compared. The refractive deviation was found 0,29±0,29 D with SRK/T formula, 0,27±0,27 D with T2 formula, 0,3±0,24 D with Hoffer Q, 0,3±0,26 D with Ladas Super Formula, 0,33±0,28 D with Barrett Universal II formula and 0,27±0,29 D with Hill-RBF formula. The percentages of cases with refractive deviation degrees of the formulas from -0,50 to +0,50 D were as follows: T2 formula with 87,7%, Hill-RBF with 86,2%, Hoffer Q and SRK/T formulas with 84,6%, Barrett Universal II with 83,1%, Ladas Super Formula with 81,5%. Refractive deviation percentages of the formulas between -1,00 D and +1,00 D were determined as follows: Hoffer Q and Hill-RBF with 98,5%, T2 formula, Ladas Super Formula, Barrett Universal II and SRK / T formula with 96,9%. There was no statistically significant difference between the formulas in terms of refractive deviation values (p>0,05). Conclusion: The chance of reaching the target refractive value with a refractive deviation within ±1 D of the 6 biometry formulas included in the study is 96,9% and above. Each of these formulas can be safely used to calculate preoperative IOL power in normal-length eyes.

Benzer Tezler

  1. Yeni bir fakoemülsifikasyon cihazı tasarımı ve uygulaması

    Design and application of a new phacoemulsification device

    HÜSEYİN HALICI

    Doktora

    Türkçe

    Türkçe

    2004

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    PROF. DR. İNCİ ÇİLESİZ

    PROF. DR. MUSTAFA ELÇİOĞLU

  2. An onto-phenomenological inquiry on the post-industrial maker experiences through the lens of actor network theory

    Post-endüstriyel yapan deneyimlerinin, aktör ağ teorisi ile onto-fenomenolojik olarak sorgulanması

    ÖZGÜN DİLEK

    Doktora

    İngilizce

    İngilizce

    2020

    Endüstri Ürünleri Tasarımıİstanbul Teknik Üniversitesi

    Endüstri Ürünleri Tasarımı Ana Bilim Dalı

    DOÇ. DR. ÇİĞDEM KAYA

  3. An adaptation study: Diana Gabaldon's“Outlander”as a TV adaptation

    Bir adaptasyon çalışması: Diana Gabaldon'un“Outlander”isimli eserinin televizyon adaptasyonu

    NUR EFŞAN GÜL

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    İngiliz Dili ve EdebiyatıSelçuk Üniversitesi

    İngiliz Dili ve Edebiyatı Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HÜSEYİN ALTINDİŞ

  4. Design and implementation of capacitive micromachined ultrasonic transducers for high intensity focused ultrasound

    Yoğunluklu odaklanmış yüksek frekanslı ses tedavisi için kapasitif mikroişlenmiş ultrasonik dönüştürücülerin tasarımı ve gerçekleştirilmesi

    FEYSEL YALÇIN YAMANER

    Doktora

    İngilizce

    İngilizce

    2011

    Elektrik ve Elektronik MühendisliğiSabancı Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. AYHAN BOZKURT

  5. Şekillendirilmiş lazer hüzmelerinin yüksek saçılmalı ortamla etkileşimleri

    Interactions of shaped laser beams with highly scattering media

    TANSU ERSOY

    Doktora

    Türkçe

    Türkçe

    2016

    Fizik ve Fizik Mühendisliğiİstanbul Teknik Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. SELÇUK AKTÜRK